Act1 Electrofusion Welder
06/06/2011
www.ProcessPipes.co.uk
Pg 11
Set Up Options
From the main menu: Press the D Quick-Key to select options.
From here the time can be set by the operator. Other changes can be made, however, these are
password protected and must be carried out by an approved service agent.
The following options are available:
Date.
The date can be set.
Display Language.
Available languages can be selected and set.
Modes of Operation.
Manual: On/Off, Cooling time On/Off, Variable voltage On/Off.
Calibration Period.
The calibration period can be set between 1 month and 99 months (or turned off). For 28 days
prior to the calibration expiry date, the unit will prompt that the calibration is due and will count
down the remaining days. When the calibration has expired, it can be set to warn the operator or
lock the unit.
Owner Details.
The owner details, shown when the unit is first switched on, can be entered or changed.
Download Format.
The format of the data log download can be changed from protected PFD to plain text XLS.
Purchase Date.
The date the unit was sold to the customer can be set and viewed. This allows more accurate
record keeping.
Warranty Period.
The date the unit was first used can be viewed. This allows accurate control of the warranty
period.
Summary of Contents for Act1
Page 1: ...Act1 Electrofusion Welder ...
Page 27: ......