background image

Usage

Warm-up

After power on, the detector will warm-up within 180 second and

screen says “Waiting” with countdown ticking sound.

Working

The screen displays the working window and clock panel per 1

minute in turn.

Wi-Fi icon

Connected to network with dot.

Offline if it is shown in gray.

None means Wi-Fi module failure.

Life

Days remained

Fault is shown at sensor

fault

Hour

Temperature

around

Minute

Summary of Contents for CP-WG01W

Page 1: ...Range 0 100 LEL Wi Fi Gas Leak Detector User Guide ...

Page 2: ...r to turn gas leak source off It is also a fire alarm device with the built in heat sensor designed to respond when the convected thermal energy of a fire increases the temperature You can get the gas level and temperature via a mobile application from any point of the world and an Internet connection via a Wi Fi 802 11 b g n 2 4GHz network is required for operation TFT color LCD screen displays w...

Page 3: ... Sample Diffusion Range 0 100 LEL Alarm setting value 6 LEL Tolerance 3 LEL Response time 30 seconds Heat alarm value 57 Alarm volume 70dB Alarm with Indicator sound voice prompt and APP notification push Valve manipulator drive output 12V 300mA output for 15 seconds Warm up time 180 seconds Sensor life 5 years Wi Fi 2 4GHz IEEE802 11b g n Dimensions 86x86x24 5mm ...

Page 4: ...ter x1 Mounting adhesive tap x1 Screws x2 User guide x1 At a glance USB 5V power port Wi Fi configuration Clock adjustment Test Silence button Red alarm indicator Yellow fault indicator Green power indicator Yellow life indicator Display screen ...

Page 5: ... What it means Power Green Power is ok Alarm Blinking red Gas leak or heat alarm Fault Blinking yellow Sensor is fault Life Blinking yellow Sensor life is over Middle socket is for manipulator Right socket is for valve control Bracket ...

Page 6: ...n then power your detector on don t release until the screen says Smart Mode Connecting Tap Fast flashing wait the configuration finishes Tap to name your detector then tap Done 2 Soft AP Mode Please change to Soft AP Mode if the configuration fails in Smarlink Mode Power your detector off Press and hold the button then power your detector on don t release until the screen says Smart Mode Connecti...

Page 7: ...is comprised of methane gas is lighter than air in case of gas leakage gas rises towards ceiling and accumulates in areas near ceiling Therefore for natural gas the alarm apparatus shall be located in a position of 30 cm under the ceiling and 1 5 4 meter s away from gas supply LPG that is comprised of mixture of propane and butane is heavier than air In case of gas leakage LPG falls down to ground...

Page 8: ...included screws Holding your detector against the bracket and turn it clockwise to fix it in the bracket 2 Using adhesive tap Tear off one side of the double sides adhesive tap and stick it to the underside of detector tear off the other side and attach detector to a flat surface ...

Page 9: ... with countdown ticking sound Working The screen displays the working window and clock panel per 1 minute in turn Wi Fi icon Connected to network with dot Offline if it is shown in gray None means Wi Fi module failure Life Days remained Fault is shown at sensor fault Hour Temperature around Minute ...

Page 10: ... pushed to your mobile and valve manipulator is drove to turn the gas source off Heat alarm When the temperature around detector increases to preset value the red alarm indicator flashes the value ring is displayed Heat alarm Check now is heard and a same text notification is pushed to your mobile Silence In case of alarm click the button or tap in APP to mute the alarm sound and the screen says A...

Page 11: ...of sensor failure you hears The sensor failed Check now and your mobile get the same text notification Clock adjustment The date and time are usually updated automatically over the network if your detector is connected to network via Wi Fi If NOT you can adjust the date and time by the button Without alarm press and hold the button until the date and time setting window is displayed The digit is i...

Page 12: ...substances with very strong odors very intense meal and water vapors may cause to alarm to malfunction by misleading the apparatus This product is only used to reduce the accident cannot make sure everything Except that use our detector in right way please pay more attention in your daily life and strengthen safety and security consciousness ...