5
Technical
Nominal
Voltage:
12
volts DC
Voltage range:
9-15 volts DC
Sounder
Type:
Tone
(Piezo)
Sound output level :
112 dB (A) @ 1 metre
Sound only Current:
84mA @ 12volts dc
Sound
duration:
Determined
by
control
panel.
Flash only current:
17mA @ 12volts dc
Sound and flash:
100mA @ 12volts dc
System Status Current:
4mA @ 12volts dc
Temperature Range:
-15° C to +40° C
Tamper Detection
Lid and mounting surface removal.
Housing
Base
Material:
Polycarbonate
Lid
Material:
ABS
Dimension (mm):
125mm x 85mm x 37.5mm
Specifications
SO/PICCOLO/**/G3/S5
12 volt Internal Sounder
** denotes lens and lid colour
Low profile design.
11
2
dB sound output.
Selectable alternating or continuous tone.
Flashing alarm indication.
System status indicator
Low current consumption.
Tamper protected lid and mounting.
Tamper
C
F
S
Tamper
Linked Sound & Flash
Tamper
C
F
S
Tamper
Flash only
Tamper
C
F
S
Tamper
Sound only
Tamper
C
F
S
Tamper
Independent Sound & Flash
-ve
-ve
+ve
+ve
Not Connected
Not Connected
-ve
+ve
+ve sound
+ve flash
-ve common
Link
S = Sound +ve
F = Flashing LED’s +ve
C = Common -ve
Tamper x 2 = Lid and mounting surface tamper.
System status indication x 2
Connection Examples
FIRE & SECURITY
-ve supply
+ve supply
System status indication
. (Permanently illuminates LED’s at lower intensity.)
EN50131-1:2006 + A1:2009
:Security
Grade
3
Environmental
Class
II
EN50131-4:2009
Warning device type
: Internal Remotely Powered
Safety Precautions
Always observe local regulations when disposing of this unit
Plastic bags can suffocate, always dispose of packaging carefully
This remotely powered internal sounder can be installed in security systems up to and
including Grade 3 Environmental class II in accordance with EN50131:2006 + A1:2009. It is
certified by Telefication to EN50131-4:2009. The warning device gives an audible and visual
signal of alarm activation. The LED’s can also be wired independantly to indicate the system
status. The sound output is selectable for either alternating or continuous tone. It is also
protected against tampering by means of lid removal and removal from the mounting
surface.