Super Shot 60 Propane Melter Part Manual
Chapter 8 Troubleshooting
©2018 by Crafco, Inc. All Rights Reserved
………………...…………………………..……………...Illustrated Parts List 8-25
Symtom: Trigger is not Working
8.3.2
Step
Possible Cause
If . . .
1
Check continuity between two red wires
coming from the hose in junction box.
NOTE:
These wires must be disconnected
from the terminal block and the trigger
depressed to perform this test.
No, go to Step 2.
2
Disconnect the electrical connector between
the hose and wand, check for continuity
between C and B wand side.
Yes, this hose needs to be repaired or
replaced. Contact Crafco, Inc. to send
back the hose for repair.
No, this wand needs to be repaired or
replaced. Contact Crafco, Inc. to send
back the hose for repair.
Table 8-20 Trigger is Not Working