17
TROUBLE SHOOTING
Machine doesn’t turn
on or trips breaker
when turned on
SYMPTOM
POSSIBLE CAUSE
POSSIBLE SOLUTION
1. Capacitor is faulty
2. Centrifugal switch is
faulty
3. Motor ON/OFF switch is
faulty
4. Motor is faulty
5. Motor connection wired
incorrectly
1. Test and replace
capacitor if needed
2. Adjust or replace
centrifugal switch
3. Replace ON/OFF
switch if faulty
4. Test, replace or
repair motor
5. Make sure motor is
wired correctly
1. Conveyor is too loose
2. Excessive Load
1. Tension the
conveyor properly
2. Reduce the load
Conveyor Slips when
sanding under load
1. Conveyor not tracking
properly
1. Track the conveyor
properly
(see page 13)
Conveyor tracks to
one side only
1. Low power supply
voltage
2. Belt is slipping
3. Poor Dust Collection
4. Machine overload
5. Overheated Motor
1. Ensure that all lines
and grounds are
operations and have
correct voltage
2. Replace belt and re-
check
3. Check for air leaks
seal leaks, eliminate
bends in piping and
ensure machine is
getting proper
suction from port
4. Use new sandpaper
and ensure you are
following max.
guidelines
5. Allow motor to cool
Machine stalls or
seems under powered
Summary of Contents for CT125
Page 1: ...CT125 BABY DRUM SANDER 13 ...
Page 19: ...19 CT125 PARTS LIST ...
Page 20: ...20 CT125 PARTS DIAGRAM ...
Page 21: ...21 CT125 PARTS LIST ...
Page 22: ...22 CT125 PARTS DIAGRAM ...
Page 23: ...23 CT125 PARTS LIST ...
Page 24: ...24 CT125 PARTS DIAGRAM ...
Page 26: ...26 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...