background image

 

4

 

Read and understand the instruction manual before operating the dust collector. 
Basic precautions listed below should always be followed when using your dust 
collector to reduce the risk of injury, electrical shock or fire. 
 
 

 The CX404 is designed to collect 

sawdust only

 

 

NEVER

 attempt to use this dust 

collector to vacuum water or any other 

liquids.

 

 

 

NEVER

 try to use this dust collector to 

collect large wood pieces. 

 

 

NEVER

 attempt to use this dust 

collector to collect metal materials 

such as screws, nails or other metal 

parts. 

 

 

ALWAYS 

wear respiratory and safety 

glasses when emptying dust from the 

collection bags. 

 

NEVER

 operate the dust collector with 

all blast gates closed. 

 

 

ALWAYS

 disconnect the dust collector 

from its power source when changing 

or emptying the bags. 

 

 

ALWAYS

 be sure that the collection 

and filter bags are securely fastened to 

collector body.

 

 

 

DO NOT 

place your hand or tools 

nears the open inlet while operation. 

Serious personal injury or damage to 

the machine can happen.

 

 

 

ALWAYS

 connect dust collector to the 

matched power source.

 

 

CX404 – 1 HP DUST COLLECTOR 

SPECIFIC SAFETY INSTRUCTIONS 

 

IMPORTANT 

The safety instructions given above can not be complete because the environment in 
every shop is different. Always consider safety first as it applies to your individual 
working conditions

 

Summary of Contents for CX404

Page 1: ...CX404 1 HP DUST COLLECTOR User Manual ...

Page 2: ...04 Specific Safety Instructions 4 Features 5 Physical Features 6 Unpacking 7 Setup 7 Proper Grounding 8 Assembly 9 Test Run 11 Operation 11 Maintenance 12 Bag Cleaning 12 Cleaning the Canister 12 Lubrication 12 Parts Breakdown 13 Parts List 14 Warranty 15 ...

Page 3: ...tors should be kept a safe distance from work area NEVER leave a tool unattended while the machine is in operation DON T OVERREACH Keep proper footing and balance at all times DISCONNECT the machine from the power source when changing drill bits hollow chisels router bits shaper heads blades knives or making other adjustments or repairs SECURE WORK Use clamps or a vise to hold work when practical ...

Page 4: ...and safety glasses when emptying dust from the collection bags NEVER operate the dust collector with all blast gates closed ALWAYS disconnect the dust collector from its power source when changing or emptying the bags ALWAYS be sure that the collection and filter bags are securely fastened to collector body DO NOT place your hand or tools nears the open inlet while operation Serious personal injur...

Page 5: ...04 is a professional tool and like all power tools proper care and safety procedures should be adhered to Motor 1 HP 110 Volt 7 Amps Safety Power Switch with Removable Key Balanced Steel Impeller Yes Impeller Size 10 Lower Bags Easy On Bags Lower Bag Volume 2 67 Cubic Feet Upper Bags One Micron Upper Filtration Bag Static Pressure 6 Air Suction Capacity 825 CFM Intakes One 4 Weight 28 Kg Warranty ...

Page 6: ...CX404 1 HP DUST COLLECTOR PHYSICAL FEATURES 1 Micron Filtration Bag Collector Body Outlet Connector Impeller Assembly Support Casters Base Easy On Collection Bag Collector Ring Support Rod ...

Page 7: ... Base 1 D Impeller Support 1 E Top Bag 1 F Bottom Bag 1 G Gasket 1 H Clamps for Upper and Lower Bags 2 I Easy On Bottom Bags 5 J Casters 4 K Hardware Bag 1 SETUP Before setting up your machine you need to read and understand this user manual completely The CX404 features four casters installed to its base unit for easy mobility If you want to use the CX404 as a stationary tool do not install the c...

Page 8: ... a 3 prong grounded receptacle as shown in figure 2 Do not remove the grounding prong to fit it into a 2 pronged outlet Figure 2 110 Volts outlet for CX404 It is strongly recommended not to use extension cords with your CX404 Always try to position your machine close to the power source so that you do not need to use extension cords In case if you really find it necessary to use an extension cord ...

Page 9: ...crews and washers provided as shown in figure 4 Figure 4 Securing the impeller support to the base unit Place the motor and impeller assembly on the impeller support making sure that the square flange on the impeller is facing the rounded end of the base unit Secure the motor and impeller assembly using nuts washers and bolts provided See figure 5 Figure 5 Installing the motor and impeller assembl...

Page 10: ... collector ring support rod Attach the upper 1 micron bag to the dust collector with the bag clamp provided See figure 9 Figure 9 Installing the upper bag Your dust collector should come with a regular bottom bag as well as a set of Easy On bags Insert the belt clamp through the easy on bottom bag and attach the bottom bag to the dust collector as shown in figure 10 Figure 10 Installing the bottom...

Page 11: ...CX404 close to the machine and use a proper sized hose connecting the hose with its one end to the machine and the other end to the dust collector Make sure the connections are secured using hose clamps and connect the ducting ground and the dust collector is ready for operation FORMULAS Velocity FPM Volume CFM Cross Sectional Area ft 2 Volume CFM Velocity FPM x Cross Sectional Area ft 2 Cross Sec...

Page 12: ...and is very injurious to health Since the CX404 is comes with Easy On collection bag you do not have to remove the clamp from the collection bag Simply Un clamp the bag and empty it Re install the bag and clamp it CLEANING THE CANISTER If using a canister The canister has a cleaning handle which allows for easy cleaning of the canister by simply rotating the handle After each use rotate the handle...

Page 13: ...13 CX404 DUST COLLECTOR PARTS BREAKDOWN ...

Page 14: ...1 12 Washer 5 16 4 12 1 Nut 5 16 4 13 Hex Screw 1 4 x 1 2 4 14 Hex Screw 5 16 x 1 2 4 14 1 Hex Screw 5 16 x 3 4 4 15 Hex Screw 1 4 x 1 2 6 16 Switch 1 17 Switch Key 1 18 Motor 1 19 Gasket 1 20 Column 1 20 1 Column Flange 1 21 Key 5mm x 5mm x 30mm 1 22 Packing 1 23 Collector Ring 1 24 Easy On Collection Bag 1 25 Filter Bag 1 26 Power Cord 1 27 Open End Wrench 10mm x 12mm 1 28 Hex Wrench 5mm 1 CX404...

Page 15: ...er handy All returned merchandise will be subject to a minimum charge of 15 for re stocking and handling with the following qualifications Returns must be pre authorized by us in writing We do not accept collect shipments Items returned for warranty purposes must be insured and shipped pre paid to the nearest warehouse Returns must be accompanied with a copy of your original invoice as proof of pu...