CAUTION
:
Be sure outlet box is properly grounded and
that a ground wire (
GREEN
or Bare) is present.
Make sure all electrical connections comply with Local
Codes or Ordinances and the National Electrical Code. If
you are unfamiliar with electrical wiring or if the
house/building wires are different colors than those
referred to in the instructions below, please use a
qualified electrician.
Note
:
Excess lead wire length from the fan can be cut
to the desired length and then stripped.
When downrod is secured in place on the hanging
bracket, electrical wiring can be made as follows:
Connect
BLACK
wire from fan to
BLACK
wire from
ceiling with wire connector provided.
Connect
WHITE
wire from fan to
WHITE
wire from
ceiling with wire connector provided.
Connect all
GROUND
(
GREEN
) wires together from
fan to
BARE
/
GREEN
wire from ceiling with wire
connector provided.
Since this fan does not come with a light kit, you will
need to cap off the
BLUE
wire with a wire connector
(as shown with arrow in diagram).
[
Note
: If you elect to purchase a light kit for the fan,
the
BLUE
wire from the fan must be connected to
the
BLACK
wire from the ceiling instead.]
page 5
5. Fan Assembly. (cont.)
With the hanging bracket secured to the outlet box and
able to support the fan, you are now ready to hang your
fan. Grab the fan firmly with two hands. Slide downrod
through opening in hanging bracket and let hanging ball
rest on the hanging bracket. Turn the hanging ball slot
until it lines up with the hanging bracket tab.
WARNING
: Failure to align slot in hanging ball with tab in
hanging bracket may result in serious injury or death.
Tip
: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you once you
are set on the ladder.
Find a secure attachment point (wood ceiling joist highly
recommended) and secure safety cable. It will be
necessary to use a heavy duty wood screw, washer and
lock washer (not supplied) with the safety cable loop. If
necessary, adjust the loop at the end of the safety cable.
The loop at the end of the safety cable should just fit over
the threads on the wood screw.
Test safety cable by
pulling on loose end with pliers. If the safety cable slips, the
loop must be adjusted tighter.
Extra cable slack can be left
in ceiling area.
hanging ball slot
hanging bracket tab
motor housing
safety
cable
safety cable loop
wood
ceiling
joist
wood screw
and washer
6. Wiring.
wire
connector
black
black
white
white
blue
black supply wire
ground
(green
or bare)
white supply wire
from ceiling
from fan
ground
(green or bare)
*
* Wrap each wire connector separately with electrical
tape as an extra safety measure.
This fan is remote control adaptable (remote control