background image

Summary of Contents for 16639 - 1 HP 7 Gal. Portable Air Compressor

Page 1: ...ing this product read this manual and follow all its Safety Rules and Operating Instructions Safety Instructions Installation Operation Maintenance Storage Troubleshooting Guide Parts List EspaSol p 10 Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears corn 5 2C_2005 Pam NO E101434 ...

Page 2: ...f this Craftsman Air Compressor fails due to a defect in materiel or workmanship within one year from the date of purchase RETURN ITTO ANY SEARS STORE OR PARTS AND REPAIR CENTER OR OTHER CRAFTSMAN OUTLET IN THE UNITED STATES FOR FREE REPAIR If this Craftsman Air Compressor is used for commercial or rental purposes this warranty applies for only g0 days from the date of purchase This warranty gives...

Page 3: ...ust be used Always use more air hose beiore utilizing extension cords A l extension cords used must be 12 gauge with a maximum length ol 25 ft The circuit fuse type must be a time delay Low voltage could cause damage to the motor If the air compressor is in operation all guards and covers should be attached or installed correctly If any guard or cover has been damaged do not operate the equipment ...

Page 4: ...hen reptace the air compressor Never use the air compressor after a leak has been found or try to make any modifications to the tank Never modify the air compressor s factory settings which control the tank pressure or any other function Specifications Pump Oil lube direct drive Motor 1 0 HP Induction Bore 1 65_ Stroke 126 Voltage Single Phase 120 VAC Minimum Circuit Requirement 15 Amps Air Tank C...

Page 5: ...is designed to automatically release compressed air when the air compressor reaches cut out pressure The released air should on y escape momentarily and the valve should then close J Outlet Tube I Tank Drain Valve Used to drain condensation from the air tanK Located at bottom of tank Tank Safety Valve Used to allow excess tank pressure to escape into the atmosphere This valve should only open when...

Page 6: ...ctions Check the air filter on a daily basis to be sure it is clean and in working order Grounding Instructions This product must be grounded In the event of an electrical short circuit grounding reduces the dsk of electric shock by providing an escape route for the electric current This product is equipped with a cord having a grounding wire with an appropriate grounding plug See the figure below...

Page 7: ...ds required to perform the task If using a pneumatic tool the manufacturer should have recommendations in the manual for that particular tool on operating PSI settings 9 The air compressor is now ready for use The following inflation and cleaning accessories packaged with this unit should only be operated at maximum pressure of 90PSI blow gun rubber tapered nozzle inflation needles adapter and blo...

Page 8: ... is used iRa normal working environment on a daily basis Items to Check Ohanga Chock Tank Safety Valve Overall Unit Visual Check Check Air Filter Drain Tank Check Power Cord for Damage Change Oil Check Oil Level Before each use or daity X X X X X after first 50 hours after every i00 hours X Storage For storing the air compressor be sure to do the following 1 Turn the unit off and unplug the power ...

Page 9: ...lated pressure gauge drops when an accessory is used NOTE Adjust the regulated pressure under flow conditions while accessory is being used It is normal for the gauge to show minimal pressure loss during initial use of the tool Excessive tank pressure Move the Auto On Off lever to the Off position It the unit doesn t shut off unplug it from the power source and contact a service technician Motor w...

Page 10: ...Air Compressor Model 921 166390 Exploded View 2 22 ...

Page 11: ...mpresslon ll4 2 Pressure Re of Tube 1 I PA_T_ K_ I PARTDESCRIPTION QTY I 43 I Tank I 41 I Nut Max M10 X 1 25 2 42 I Wa her Fl_ 1Dram 2 43 E101353 _Whe_l P edHub 2 44 E10149 IBolt Shoulder M10X125X 45ram 2 45 I IBOK He_ M8X 1 25 X 3_ram I 45 E1002401 Ilsolator Rubber 1 47 E10_81 Drain Valve 1 45 E1013401 PowerCord le23 X 6 ST 1 49 I Nipple 114 NPT X 13 I 50 E1009571 pressure switch 1 51 E1003941 Va...

Page 12: ...e Craftsman lega a fallar debido a un defecto de manufactura o de materiales en un plaza de un aSo desde la fecha de compra DEVUELVALQ A LATIENDA U A OTRO CENTRO CRAFTSMAN O CENTRO DE SERViCIOY PARTES SEARS EN LOS ESTADOS UNIDOS MAS CERCANO para que sea reparado sin ningdn cargo Si este compresor de aire Craftsman se usa con fines comerciales o de renta esta garantra Onicamente se apliea por 90 df...

Page 13: ...pacidad Si as neceeario antesde amplest una e tensiPnelPctrica afiada uhamanguerede aire m slarge Las extensioneselectricasdebenset de calibre 12 y tenor unaIongitudm_ ima de 7 6 metros El fusibledel circuits debeset de accion retardada Un voltajedemesiadobajopuede daParel motor AI operar el compresor redes los protectores y cubiertas deben ester fijades e instslados correctsmente Si alguno de los...

Page 14: ...6n i el tanque tiene una fuga reemplace el compresor Nunoa utilice el oompresor si se ha detectado una fuga ni trate de modificar el tenque Nunoa modifique los ajustes de fabrics del eempreser que oontrolan a presi6n de tanque y demAs funeiones Especificaciones Bombs De impulsi6n directs lubrioada con aceite Motor 1 0 HP InducoiSn Di metro 42 mm Carrera t32 mm Volteie monof_sico 120 VAC Capacidad ...

Page 15: ... Or Of_ de a unidad r V4tvula de alivio de presiSn Esta v lvula que se encuentra en el oostado deL interrupter de presiSn esta diseRada para liberar aire comprimido de m_nera autom_tica cuaedo el compresor Ilegue a ia presi6n de pareda El aire s6 o deber_ esoapar durante un instante cerrandose la v_lvula se cerrara en seguida _lvuia de seguridad ciel tanque Permite que el exceso de presi6n en el t...

Page 16: ...es Per favor revise diarlem ente el filtrn de sire pare comprobar que est_ limpie yen corrects eetado de funeionam ier_to lnstrucaiohee de conezi6n a tierra Este products se debe conectar a tisrre En case de cortoeireuito la oonexi6n a tierra reduce e riesgo de deeoargae electricas al ofrecer una ruts de escape pare la corriente el_ ctrica Este products cuenta con un cable qua tiene un alem bre de...

Page 17: ...recomendada PSI pars su aplicaci6n oeraier ndose de qua est_ dentro de tas normas de seguridad para Ilevar a cabo la tarea Para las herramientas neuma tiaas el manual del fabrieante debe tenet recomendacienes sabre su presi6n de operaei6n PSI g Ahora el eompresor del aire asta listo para ser usado Los siguientes accesorios de infiado y de limpiaza los cuales vienen con esta unidad s6io se deben op...

Page 18: ...mente Asuntos pare verificsrl Antes de cads use cambiar o diariamente Reviser lav_vula de seguridad del X tanque Reviser visuatmehte el aspecto X general de la unidad Reviser el filtro de sire X Drenar el tenque X Verificar que el cable eleetrico X no est_ daSado Cambier e aceite Despuesde l_s primeras 50horas Vefificar el nivel del aceite Deepu sde cada 100 hores Almacenamiento Pare atmacenar el ...

Page 19: ...n regulade aae al user un aoeesorio Presi6n exoesiva en el tanque El motor no arranca Humedad exceeiva en el aire de salida Fugas de aire an el euerpo o la soldadura del tanque Ajuste la presi6n regulada bejo eondieiones de flujo mientras se utilize un accesorio Es normal que el man6metro indique una cards de presi6n mfnima al comenzar e utilizer la herramienta Apague el interrupter de encendido S...

Page 20: ...nd electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A only WWW saars _om To purchase a protection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaciSn Au Canada pour service en fran_ai_ a domicilio y para ordena...

Reviews: