Location of the Air Compressor 
The air compressor should always be located 
in a clean, dry and well-ventilated 
environment. The unit should have at 
minimum, 12 inches of space on each side. 
The air filter intake should be free of any 
debris or obstructions. Check the air filter on 
a daily basis to make sure it is clean and in 
working order. 

Grounding Instructions 
This product must be grounded. In the event 
of an electrical short circuit, grounding 
reduces the risk of electric shock by providing 
an escape wire for the electric current. This 
product is equipped with a cord having a 
grounding wire with an appropriate grounding 
plug. (See figure below.) The plug must be 
plugged into an outlet that is properly installed 
and grounded in accordance with all local 
codes and ordinances. Check with a qualified 
electrician or service personnel if these 
instructions are not completely understood or 
if in doubt as to whether the tool is properly 
grounded. 
 
 

Make sure that the product is connected to an 
outlet having the same configuration as the 
plug. No adapter should be used with this 
product. If the product must be reconnected 
for use on a different type of electric circuit, 
qualified service personnel should make the 
reconnection. 
 
Extension Cords 
Use only a 3-wire extension cord that has a 
3-blade grounding plug, and a 3-slot 
receptacle that will accept the plug on the 
product. Make sure your extension  
cord is in good condition. When using an 
extension cord, be sure to use one heavy 
enough to carry the current your product will 
draw. Cords must not exceed 25 feet and # 
12 AWG must be used. An undersized cord 
will cause a drop in line voltage resulting in 
loss of power and overheating. 

 

Break-In Procedures 
No break-in procedure is required by the 
user. This product is factory tested to 
ensure proper operation and performance.

 

 

 

 
 
 
 

WARNING! 

Improper installation of the grounding plug will 
result in a risk of electric shock. If repair or 
replacement of the cord or plug is necessary, do 
not connect the grounding wire to either flat 
blade terminal. The wire with insulation having 
an outer surface that is green with or without 
yellow stripes is the grounding wire. Check 
with a qualified electrician or serviceman if the 
grounding instructions are not completely 
understood, or if in doubt as to whether the 
product is properly grounded. Do not modify the 
plug provided; if it will not fit the outlet, have the 
proper outlet installed by a qualified electrician. 

 

This product is for use on a circuit having a 
nominal rating of 120 Volts and is factory- 
equipped with a  specific  electric  cord  and  plug 
to permit connection to a proper electric circuit. 

Plug 

Grounding Pin 

Grounded  
Outlet 

Summary of Contents for 218.10012

Page 1: ...CAUTION Before using this product read this manual and follow all its Safety Rules and Operating Instructions Safety Instructions Installation Operation Maintenance Storage Troubleshooting Guide Parts List Transform SR Brands Management LLC Hoffman Estates IL 60179 U S A 08 08 2019 ...

Page 2: ...ONE YEAR from the date of sale this product is warranted against any defects in material or workmanship WITH PROOF OF SALE return a defective product to the retailer from which it was purchased for free replacement This warranty applies for only 90 days from the date of sale if this product is ever used while providing commercial services or if rented to another person This warranty gives you spec...

Page 3: ...t be used Always use more air hose before utilizing extension cords All extension cords used must be 12 gauge with a maximum length of 25 ft The circuit fuse type must be a time delay Low Voltage could cause damage to the motor Risk of Moving Parts If the air compressor is in operation all guards and covers should be attached or installed correctly If any guard or cover has been damaged do not ope...

Page 4: ...place the air compressor Never use the air com pressor after a leak has been found or try to make any modifications to the tank Never modify the air compressor s factory settings which control the tank pressure or any other function Specifications Pump Oil lube direct drive Motor 1 0 HP Induction Bore 1 65 Stroke 1 26 Voltage Single Phase 120 VAC Minimum Circuit Requirement 15 Amps Glossary CFM Cu...

Page 5: ... the tank pressure is above the maximum rated pressure Pressure Relief Valve The pressure relief valve located on the side of the pressure switch is designed to automatically release compressed air when the air compressor reaches cut out pressure The released air should only escape momentarily and the valve should then close Outlet Tube Tank Drain Valve Regulator The pressure coming from the air t...

Page 6: ...service dealer Assembly 1 Remove air compressor manual air filter assembly and accessories from packaging 2 Remove the plastic plug from the compressor intake port see diagram below 3 Install the filter in the compressor intake port see diagram below 4 Remove the oil fill cap from the crankcase and fill until the oil reaches the top of the red dot in the sight glass Oil capacity is 2 7 oz see belo...

Page 7: ...Extension Cords Use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the product Make sure your extension cord is in good condition When using an extension cord be sure to use one heavy enough to carry the current your product will draw Cords must not exceed 25 feet and 12 AWG must be used An undersized cord will cause a drop in li...

Page 8: ...to a PSI setting that is needed for your application and be sure it is within the safety standards required to perform the task If using a pneumatic tool the manufacturer should have recommendations in the manual for that particular tool on operating PSI settings 9 The air compressor is now ready for use Daily Shut Down Procedures 1 Set the Auto On Off lever to the Off position 2 Unplug the power ...

Page 9: ...led from the tank and allowed time to cool before any maintenance is performed CAUTION To ensure efficient operation and longer life of the air compressor unit a routine maintenance schedule should be followed The following schedule is geared toward a consumer whose compressor is used in a normal working environ ment on a daily basis Storage For storing the air compressor be sure to do the followi...

Page 10: ...ure drop when the accessory is used replace the regulator NOTE Adjust the regulated pressure under flow conditions while accessory is being used It is normal for the gauge to show minimal pressure loss during initial use of the tool Excessive tank pres sure Move the Auto On Off lever to the Off position If the unit doesn t shut off unplug it from the power source and contact a service technician M...

Page 11: ...9 Craftsman Air Compressor Model 218 10012 Exploded View ...

Page 12: ...12 x 34 mm 1 26 B 46 005 Ring Snap 12 mm 2 27 B 29 001 Ring scraper Dia 42 mm 1 28 B 29 001 Ring compression Dia 42 mm 2 29 C 36 022 Baffle rubber 1 30 C 03 006 Cover crankcase 1 31 C 33 001 Gauge oil sight with seal 1 32 C 45 085 Screw hex flange head M5 x 12 mm 10 33 C 26 004 Oil fill cap with O ring 1 34 B 04 019 Centrifugal switch 1 35 C 45 108 Screw round head phillips M5 x 10 mm 2 36 C 45 06...

Page 13: ...be relief outlet OD 6 mm 1 60 E 44 001 Nut hex compression G1 8 1 61 F 22 034 Cord Power SJT16 2M 1 62 F 46 050 Terminal Y type 1 5 4U 2 63 F 46 051 Terminal O Type 1 5 4O 1 Note Any part kit field without a number is not available Descriptions are provided for reference only The Kit column means that the part being offered is only in a kit One of each part per kit is included ...

Page 14: ...For product questions or to order replacement parts call 1 877 636 0533 ...

Reviews: