For best results and more efficient power, it is recommended that you operate your inflator with your 
VEHICLE‟S ENGINE RUNNING, making absolutely sure you are outside or in an open, well-ventilated 
area and NOT INSIDE A CONFINED AREA, SUCH AS A GARAGE as bodily injury or asphyxiation 
resulting in death could occur. 

ALWAYS ALLOW FOR PROPER VENTILATION. 

 Most vehicle 12 Volt 

power outlets will operate with vehicle ignition off; however, some vehicles require that the ignition be 
turned on.

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

Save these instructions 

 

Improper operation or maintenance of this product could result in serious injury and property 
damage.  Read and understand all warnings and operation instructions before using this 
equipment. 
 
 

HAZARD 

 

WARNING:

  

Risk of explosion or fire

 

 

What Could Happen 

How To Prevent It 

It is normal for electrical contacts 

within the motor 

to spark. 

Always 

operate the inflator in a 

well ventilated 

area free of combustible materials, gasoline, or 
solvent vapors.

 

If

 electrical 

sparks 

from inflator 

come into contact with 
flammable vapors, they may 
ignite, causing fire or explosion. 

Store flammable materials in a secure location 
away from inflator. 

Restricting 

any of the 

inflator 

ventilation openings

 will cause 

serious overheating and 

could 

cause fire. 

Never place objects against or on top of inflator.  
Operate inflator

 in an open area 

at least 12 

inches away from

 any 

wall or obstruction 

that 

would restrict the flow of fresh air to the ventilation 
openings.   

Do not operate unit in any confined area. 

Unattended operation 

of this 

product 

could result in personal 

injury or property damage.  To 
reduce the risk of fire, do not 
allow the inflator to operate 
unattended. 

Always remain in attendance 

with the product 

when it is operating.  

Always disconnect power by 

moving on/off switch to the off position and 
unplug the power cord. 

 
 
 
 

 
 
 
 
 
 

 
 
 

3

 

Summary of Contents for 75114

Page 1: ...N Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com Safety Guidelines Assembly Operation Maintenance Troubleshooting ...

Page 2: ...be replaced free of charge For warranty coverage details to obtain free replacement visit the web site www craftsman com This warranty does not cover the air needle which is an expendable part that can wear out from normal use within the warranty period This warranty is void if this product is ever used while providing commercial services or if rented to another person This warranty gives you spec...

Page 3: ...o reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of personal injury Use 12 Volt DC only Make sure that your vehicle 12 Volt power outlet is free of an...

Page 4: ...or electrical contacts within the motor to spark Always operate the inflator in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from inflator come into contact with flammable vapors they may ignite causing fire or explosion Store flammable materials in a secure location away from inflator Restricting any of the inflator ventilation openings will...

Page 5: ...tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed resulting in property damage or personal injury Always wear ANSI Z87 1 approved safety glasses with side shields when using the inflator Never direct compressed air toward any part of the body or at other people or animals Always turn the inflator off before attempting maintenance or attaching a...

Page 6: ...tact with you your clothing loose hair or jewelry Never operate the inflator with guards or covers which are damaged or removed Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be preformed by authorized service cen...

Page 7: ...features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts HAZARD WARNING Risk of Injury Do not direct air stream at body Disconnect from supply circuitry before replacing fuse SAVE THESE INSTRUCTIONS GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet ...

Page 8: ... to the Quick Connect Universal Valve Adaptor to inflate small inflatable items such as mattresses and beach balls ASSEMBLY Contents of Carton To Remove Inflator from Carton 1 Inflator equipped with rubber air hose built in Quick Connect Universal Valve Adaptor and digital pressure gauge 1 Air Needle 1 Small Adaptor 1 Presta Valve Adaptor 1 Grasp handle and lift the Inflator out of the carton 2 Re...

Page 9: ...ptor Attaches directly to the Quick Connect Universal Valve Adaptor to inflate small inflatable mattresses and beach balls Presta Valve Adaptor Used to inflate high performance bike tires Quick Connect Universal Valve Adaptor Used with standard tire valves and with accessories included with Inflator Air Needle Attaches directly to the Quick Connect Universal Valve Adaptor to inflate sport balls WA...

Page 10: ...he pressure gauge on the unit is for general reference only To inflate sports ball air mattress rubber raft etc 1 Place Inflator evenly on flat surface 2 Select the appropriate inflation accessory and insert into the Quick Connect Universal Valve Adaptor and push down the Valve Lock Lever to secure the connection 3 Connect the 12 Volt power cord into DC 12 Volt power outlet 4 Insert the inflation ...

Page 11: ...conds 6 For Automatic Shut Off switch the Pump switch to Preset In the Preset Mode the Inflator will automatically shut off when it reaches the preset pressure setting 7 Turn the Inflator Pump switch to the Off position when finished CAUTION Do Not Over Inflate NOTE If low pressure is present below 3 PSI the gauge will turn off automatically after 15 seconds The gauge will remain on if the pressur...

Page 12: ...KG CM 2 or KPA 5 When pumping there is approximately 1 to 2 PSI difference between the tire pressure and the display figure due to the air hose back pressure 6 The digital gauge display will be subject to fluctuation while pumping 7 The digital gauge will automatically shut off in 15 seconds when the pressure is under 3 PSI 8 When the batteries in the Digital Tire Pressure Gauge are getting low th...

Page 13: ...ARNING Risk of Unsafe Operation Voltage sources moving parts or compressed air sources are exposed when repairing the inflator Personal injury can occur Unplug the inflator before attempting the repairs PROBLEM CAUSE CORRECTION Motor will not run Blown Fuse Faulty motor 1 Check fuse in end of 12 Volt plug See diagram below 2 Check automobile fuse for 12 Volt receptacle Contact 1 800 874 5771 SPECI...

Page 14: ... expert advice www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY ...