background image

HAZARD 

 

 

WARNING: Risk of Burns  

 

What Could Happen 

How To Prevent It 

Touching exposed metal 

such as the 

inflator head or outlet tubes, 

can result 

in serious burns. 

Never touch any exposed metal parts on 
inflator 

during or immediately after 

operation.  

Inflator will remain hot 

for 

several minutes after operation.  

Do not 

reach around protective shrouds or 

attempt 

maintenance until unit has been allowed 
to cool.

 

 
 
 
 

HAZARD 

 

WARNING:  Risk from Moving Parts 

 

What Could Happen 

How To Prevent It 

Moving parts 

such as the pulley, 

flywheel, and belt 

can cause serious 

injury 

if they come into contact with 

you, your clothing, loose hair, or 
jewelry. 

Never operate the inflator with guards 

or 

covers which are 

damaged or removed. 

Attempting to operate 

inflator 

with 

damaged or missing parts 

or 

attempting to repair inflator with 
protective shrouds removed can expose 
you to moving parts and 

can result in 

serious injury. 

Any 

repairs 

required on this product 

should be preformed by authorized 
service center personnel. 

 
 
 
 
 

HAZARD 

 

WARNING:  Risk of Falling 

 

What Could Happen 

How To Prevent It 

An inflator 

can fall 

from a table or 

workbench 

causing damage to the 

inflator and could result in serious 
injury or death to the operator. 

Always 

operate inflator in a stable secure 

position 

to prevent accidental movement of 

the unit.  

Never operate inflator on a roof 

or other elevated position. 

 
 

 
 
 

Summary of Contents for 75120

Page 1: ...N Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Brands Management Corporation Hoffman Estates IL 60179 U S A Visit our Craftsman website www craftsman com Safety Guidelines Assembly Operation Maintenance Troubleshooting ...

Page 2: ...nty coverage details to obtain free replacement visit the web site www craftsman com This warranty does not cover the air needle which is an expendable part that can wear out from normal use within the warranty period This warranty is void if this product is ever used while providing commercial services or if rented to another person This warranty gives you specific legal rights and you may also h...

Page 3: ...o reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment always wear MSHA NIOSH approved properly fitting face mask or respirator when using such tools When using air tools basic safety precautions should always be followed to reduce the risk of personal injury Use 12 Volt DC only Make sure that your vehicle 12 Volt power outlet is free of an...

Page 4: ...or electrical contacts within the motor to spark Always operate the inflator in a well ventilated area free of combustible materials gasoline or solvent vapors If electrical sparks from inflator come into contact with flammable vapors they may ignite causing fire or explosion Store flammable materials in a secure location away from inflator Restricting any of the inflator ventilation openings will...

Page 5: ...tissue damage to exposed skin and can propel dirt chips loose particles and small objects at high speed resulting in property damage or personal injury Always wear ANSI Z87 1 approved safety glasses with side shields when using the inflator Never direct compressed air toward any part of the body or at other people or animals Always turn the inflator off before attempting maintenance or attaching a...

Page 6: ...tact with you your clothing loose hair or jewelry Never operate the inflator with guards or covers which are damaged or removed Attempting to operate inflator with damaged or missing parts or attempting to repair inflator with protective shrouds removed can expose you to moving parts and can result in serious injury Any repairs required on this product should be preformed by authorized service cen...

Page 7: ...features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts HAZARD WARNING Risk of Injury Do not direct air stream at body Disconnect from supply circuitry before replacing fuse SAVE THESE INSTRUCTIONS GLOSSARY Become familiar with these terms before operating the unit CFM Cubic feet per minute SCFM Standard cubic feet ...

Page 8: ... air mattresses small boats inflatable toys and other items that require large volume of low pressure air ASSEMBLY Contents of Carton To Remove Inflator from Carton 1 Inflator equipped with rubber air hose and pressure gauge PVC Coil Air Hose with built in Screw on valve 1 Inflation Accessory Kit 1 Air Needle 1 Presta Valve Adaptor 1 High Flow Inflator Deflator Adaptor with three nozzles and seal ...

Page 9: ...le Attaches directly to the screw on valve to inflate sport balls High Flow Inflator Deflator Adaptor Used with inflator deflator nozzles this adaptor attaches directly to the screw on valve to inflate or deflate air mattresses small boats inflatable toys and other items that require a large volume of low pressure air Inflator Deflator Nozzles Used with High Flow Inflator Deflator Adaptor Seal Rin...

Page 10: ... the pressure gauge on the unit is for general reference only To inflate sports ball air mattress rubber raft etc 1 Remove 12 Volt Direct Drive Inflator from carrying case and place evenly on flat surface 2 Connect the PVC coil air hose to the Inflator by pulling back on the quick connect coupler collar and inserting this on valve located on the end of the 1 foot rubber air hose Push in firmly and...

Page 11: ...ery large air inlets Insert nozzle thru seal ring as shown 3 The high flow inflator deflator adaptor has an inflation outlet and deflation outlet Attach the nozzle to the preferred outlet NOTE Inflation and Deflation are marked at outlets Inflation Position Deflation Position 4 Insert nozzle into inflatable and start inflator NOTE If inflatable is not getting firm enough place thumb over the defla...

Page 12: ...ARNING Risk of Unsafe Operation Voltage sources moving parts or compressed air sources are exposed when repairing the inflator Personal injury can occur Unplug the inflator before attempting the repairs PROBLEM CAUSE CORRECTION Motor will not run Blown Fuse Faulty motor 1 Check fuse in end of 12 Volt plug See diagram below 2 Check automobile fuse for 12 Volt receptacle Contact 1 800 874 5771 SPECI...

Page 13: ... expert advice www managemylife com For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY ...

Reviews: