4
GROUNDING OUTLET
If your outlet is not grounded, install a copper wire, at
least 14 gauge (2mm
²
), from the outlet box, as shown in
Figure B, to a metal cold water pipe. Use ground clamp
on pipe.
NOTICE The cold water pipe you use as a ground must
have metal continuity to electrical ground. If continuity is
interrupted by plastic, rubber, or other electrical insulators;
such as hoses, fittings, washers or gaskets (including
water meter or pump), a metal bypass must be used. Any
electrically insulated connector should be jumped (as
shown in Figure C), with a length of No. 4 wire clamped
securely at both ends.
AUTOMATIC THERMAL OVERLOAD PROTECTION
This pump motor has a built-in automatic thermal overload
protector. If the motor overheats, the protector will open
and cut off power to the motor before the heat damages
it internally. The overload will reset automatically and the
pump will restart after the pump cools down below the
danger point.
Risk of electric shock. Can shock, burn or
kill. DO NOT attempt to work on the pump or motor if the
overload seems to have tripped. The motor may restart
without warning at any time. You could be injured and the
pump damaged if it starts when you are working on it.
DO NOT attempt to repair a non-operational pump. Take it
to Sears for service by a qualified technician.
GENERATOR SIZING
Below is the minimum Engine-Generator Watt rating
required to power this pump motor. Any additional loads,
such as lights, must be added to the listed load and the
generator sized accordingly.
Pump
Motor HP
Minimum Watt Rating
of Generator
1/4
3200
No. 4
Wire
Clamp
Metal Water Pipe
Meter
Clamp
655 0993
Figure C
Face Plate
Outlet
Outlet
Box
Bare Copper Wire
to Cold Water Pipe
Face
Plate Screw
653 0993
Figure B
Summary of Contents for 83.2655
Page 14: ...14 NOTAS ...
Page 15: ...15 NOTAS ...