GARDEN HOSE PERFORMANCE
Type of Hose
Length of Hose
Vertical Pumping Distance
3’
5’
10’
15’
20’
1/2” HOSE
25’
9.0
8.7
7.5
6.7
5.2
50’
6.8
6.5
5.9
5.0
4.0
75’
5.2
5.0
4.6
3.7
3.1
100’
4.9
4.7
4.3
3.3
2.9
5/8” HOSE
25’
12.3
11.7
10.3
8.9
6.8
50’
9.0
8.7
7.6
6.5
4.9
75’
7.2
7.0
6.4
5.4
4.1
100’
6.4
6.2
5.5
4.9
3.8
Performance shown in gallons per minute.
PUMP PERFORMANCE
Discharge Height in Feet Above Pumping Level (in GPM)
Model
HP
0’
5’
10’
15’
20’
83.2655
1/4
30.0
25.4
21.0
15.4
6.2
For maximum performance, purchase Sump/Utility Hose Kit, SEARS Stock No. 27909.
Risk of electric shock. Can shock, burn or
kill. When servicing pump always disconnect power to
electrical outlet and remove pump electric cord from outlet.
1.
If pump does not operate:
a.
Check for loose plug at electric outlet.
b.
Check for blown fuses or tripped circuit breakers
at fuse box/circuit breaker box.
c.
If a and b above check OK, plug in a light that you
know works. If it lights, take your pump to Sears
for service. If it doesn’t light, the electrical circuit is
faulty; consult a licensed electrician.
2.
Pump starts, but blows fuses/trips circuit breakers:
After disconnecting power to pump, remove the
screen and shield from the bottom of the pump and
make sure that the impeller turns freely. Remove
any debris obstructing impeller. If pump still does
not operate correctly, return it to your nearest Sears
Service Department for repairs.
3.
Pump runs, but does not empty sump:
a.
Clean pump intake screen.
b.
Water may be entering sump faster than the
pump can discharge it.
c.
Be sure vertical distance from pump discharge
outlet to discharge pipe outlet is 22-1/2 feet
(6.9M) or less.
d.
Be sure discharge pipe is not plugged or frozen.
e.
Unplug pump. Clean out anti-airlock hole.
Restart pump.