background image

Summary of Contents for 919.165361

Page 1: ... Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman D30052 Revl 1 22 04 ...

Page 2: ...or fails due to a defect in material or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact your nearest Sears Service Center 1 800 4 MY HOME to arrange for repair or return the Air Compressor to the place of purchase for replacement If this Air Compressor is used for commercial or rental purposes this warrant applies for only ...

Page 3: ...otentially hazardous situation which if not avoided _ result in minor or moderate injury _Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in orooertv damaae IhSl_o nq 1 hd b Y _l_ _ 4 _ IP _l_o nj o _ P Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State ...

Page 4: ...fire or spray area An additional length of hose explosion may be required Store flammable materials in a secure location away from compressor Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire Unattended operation of this product could result in personal injury or property damage To reduce the risk of fire do not allow the compressor to opera...

Page 5: ...ding the pressure rating of air tools spray guns air operated accessories tires and other inflatables can cause them to explode or fly apart and could result in serious injury For essential control of air pressure you must install a pressure regulator and pressure gauge to the air outlet if not equipped of your compressor Follow the equipment manufacturers recommendation and never exceed the maxim...

Page 6: ...nd adequate fuse protection 1 1 1 111 WARNING Risk of Breathing What Could Happen How To Prevent It The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insecticides...

Page 7: ...ers which are damaged or come into contact with you or your removed clothing Attempting to operate compressor with Any repairs required on this product damaged or missing parts or attempting should be performed by authorized to repair compressor with protective service center personnel shrouds removed can expose you to moving parts and can result in serious injury 19 I I WARNING Risk of Falling Wh...

Page 8: ...WARNING Risk of Unsafe Operation What Could Happen How To Prevent It Unsafe operation of your air Compressor could lead to serious injury or death to you or others Review and understand all instructions and warnings in this manual Become familiar with the operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from the air compres...

Page 9: ...ins to build it builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet This unit is capable of powering the following Accessories The accessories are available throug...

Page 10: ...ed with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configuration as the grou...

Page 11: ...e and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Unsafe Operation Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with sp...

Page 12: ...rotect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than or equal to the tank pressure Tank Pressure Gauge The tank pressure gauge indicat...

Page 13: ... and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2 Plug the power cord into the correct branch circuit receptacle Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual 3 Open the drain ...

Page 14: ...g Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 2 Turn regulator knob clockwise to increas...

Page 15: ... the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Turn the regulator knob counter clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 ...

Page 16: ...ever to OFF and unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual or purchase a standard hose clamp at a local hardware store 5 Unscrew the check valve turn counterclockwise using a socket wrench 6 Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the ...

Page 17: ...from the regulator 4 Remove the regulator 5 Apply pipe sealant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 8 Reapply pipe sealant to outlet pressure gauge and quick connect Reassemble outlet pressure gauge and quick connect Orient outlet pressure gauge to read correctly Tig...

Page 18: ...elease safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned ...

Page 19: ...ION Move On Auto Off lever to the OFF position if the outfit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overti_hten Air tank must be replaced Do not repair the leak Risk of Bursting Do not drill into weld or otherwise modify air tank or it will weaken Th...

Page 20: ...used adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated ressure under flow conditions while accessory is being used Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace if requi...

Page 21: ...ing than that specified for your particular branch circuit Check for proper fuse You should use a time delay fuse Check for low voltage roblem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord Check wiring connection Loose electrical connections Faulty motor inside terminal box Have checked ...

Page 22: ... _ I I_o _V_l _ _o II m ___ __ _v Air Compressor Model Number 919 165361 33 1 Torqueto 10 20in lbs 3_ D30052 22 ENG ...

Page 23: ...D26618 28 LA 3108 33 D30075 34 D21921 DESCRIPTION Tank Recess Rubber Bumper 3 Screw 3 Screw 2 Nipple 1 4 18 NPTX 2 50 Drain Valve Safety Valve Regulator Quick Connect 1 4 NPT Gauge 2 2 Nipple 1 4 18 NPTX 1 5 Bushing Reducer 1 8 1 4NPT Pressure Switch Check Valve Pump Isolator 4 Pump Assembly Hose Clamp Label Drain Tank Eng Spa Power Cord Label Hot Surface Label Sears Performance Label Star Rating ...

Page 24: ...Air Compressor Model Number 919 165361 19 2O H_d Tigh_ Torque D30052 24_ ENG ...

Page 25: ...ve Screw 3 8 16 UNC Socket Head Rod Assembly Screw 10 24 Connecting Rod Cap Pre Formed Compression Ring Endbell Assembly Screw 8 32 x 375 344 Pump Isolator 5 Washer Screws 10 24 x 7 8 4 Motor Cord Hose Clamp Hose 1 4 tD x 10 Length Screw 10 9 x 50 Plastite 5 Motor Brush Replacement Support Handle Available Kits D24721 x KK 4929 KK 4964 D30324 Isolator Kit Fastener Kit Connecting Rod Kit Ring Kit N...

Page 26: ...esor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra Sears a su opei6n Io reparar o reemplazar sin eosto alguno Comuniquese con el Centro de Servicio Sears m s cercano 1 800 4 MY HOME para coordinar su reparaci6n o devuelva el compresor de aire al lugar donde Io compr6 para que Io cambien Si este compresor de aire se usase con fines c...

Page 27: ...uridad de alerta indica ana situaci6n potencialmente riesgosa la que si no es evitada podria causar da_os en la propiedade IIlv_ I _o i L t_i t _ _ l_ _l o_ ID1 _ _ 1 i1117 I i _ Algunos tipos de aserr n creados pot m quinas electricas de Iijado aserrado 3motado perforado u otras actividades de la construcci6n contienen materiales qu_micos conocidos en el Estado de California como causantes de c n...

Page 28: ...incendio no permita que el oompresor opere desatendido cbmo prevenirlo Opere siempre el compresor en un sector bien ventilado y libre de materiales combustibles gasolina o emanaciones de solvente En un tea de rociado de materiales infiamables ubique al compresor por Io menos a 6 1m 20 pies de distancia del _rea de rociado Podrla requerirse una extensi6n de la manguera Almacene los materiales infla...

Page 29: ...hen amientas _m_tic_ pistoIas rociadoras accesorios activados por aire cubiertas y otros obietos inflables puede causar su explosibn o set arrojado pudiendo ocasionar serias lesiones Para un control esencial de la presibn debe usted instalar un regulader y un medidor de presibn a la salida del aire de su compresor Si no estuviese equipado Siga las recomendaciones de los fabricantes de SUequipo y j...

Page 30: ...bles puesta a tierra 4unl It1 To ADVERTENCIA Riesgo de Inhalacibn qud puede occutrit cbmo prevenirlo E_aire comprimido proveniente del compresor no es sano para respirar El chorro de aire puede contener mon6xido de carbono vapores t6xicos o partlculas sblidas provenie_es del tanque La inhalaci6n de dichos contaminantes puede Uegar a causar serias lesiones o la muerte El tociado de materiates tales...

Page 31: ...cubiertas removidas o da_adas serias lesiones si elias entr_ran en contacto con usted o sus ropas Intentar operar el compresor con sus Cualquier reparaci6n requerida pot este partes da_adas o faitantes o la reparacibn producto debe ser efectuada por personal del compresor con sus protecciones autorizado de los servicentros removidas puede exponerlo a usted a partes movibles que podrlan resultar en...

Page 32: ...peracibn Insegura qud puede occurrir c6mo prevenido La operation insegura de su compresor de aire podria ocasionarle serias lesiones o la mueF_e a usted u otros Revise y comprenda todas las instrueciones y advertencias contenidas en este manual Familiarlcese con los m_todos de operaci6n y control del eompresor de aire Mantenga libre la zona de operacienes de persona alguna 8J3ima_es dorr_sticos y ...

Page 33: ... comienza a funcionar la presiSn de aire en el tanque comienza a aumantar Aumenta hasta an valor de presion alto fijado en f brica antes de que el motor autom ticamente se apague protegiendo a su tanque de aire de presiones m s altas que su capacidad La presiSn alta a la cual el motor seapaga se llama presion m_xima de corte Ramal Circuito el_ctrico que transporta electricidad desde el panel de co...

Page 34: ...n un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los c6digos y ordenanzas locales 1 El cable que acompafia a esta unidad tiene una espiga para conexi6n a tierra Esta DEBE set utilizada con un tomacorriente conectado a tierra IMPORTANTE El tomacorriente que set utilizado debera haber sido conectado a tierra conforme a todos los c6digos locales y ordenanzas AsegQre...

Page 35: ...cibn del voltaje y del circuito Acerca del voltaje y la minima cantidad de circuitos req_ _eridos refierase al cuadro de especificaciones _ Riesgo de Operacibn Lasegura Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a tray s de los tamales del circuito sea de 15 A 2 Qua el circuito no sea tr_ili...

Page 36: ... saltando de acuerdo a los valores prefijados en fabrica ligeramente supedores a los de presi6n de corte de la Ilave interruptora Manbmetro para conttolar le presibn de salida Este man6metro indieara la presi6n de aire disponible a la salida del regulador Esta presi6n est controlada por el regulador y as siempre menor o igual que la presi6n del tanque Manbmetro de la preeibn del tanque El man6metr...

Page 37: ... aire y cuando la v_lvula reguladora o la bomba completa del compresor haya sido reemplazade 1 Aseg_rese qae la pa_ancaOn Auto Off est_ en _aposicidn OFF NOTA Tire del acoplamiento hacia atrAs hasta percibir el clic que impide el escape del aire de la conexidn r_pida 2 Enchufe el cable de alimentacidn en el recept calo del ramal del circuito correcto Referirse aI parrafo Proteccidn del voltaje y d...

Page 38: ...n risque dangereux d _elatemenL V_rifiez la pression nominale maximum du fabricant pour tous les outUs pneomatiques et accessoires utUisds La pression de sortie do rdgulateur ne doit jamais excdder la preesion nominale maximum Mise en marche 1 Placez le levier On Auto Off la position AUTO et attendez jusqu ce que la pression augmente Le moteur s arr6tera Iorsque lapression darts le r _servoir atte...

Page 39: ...que la misma opera libremente si la v lvula quedase trabada o no trabajara comodamente debera ser reemplazada pot el mismo tipo de v_lvula Cbmo drenar el tanque 1 Coloque la palanca On Auto Off en la posici6n OFF 2 Gire la perilla del regulador contra el sentido del reloj para regular la presi6n de la salida a cero 3 Remueva la herramienta neum_ttic8 o el accesorio 4 Tire del aro de la v lvula de ...

Page 40: ... en On Auto OFF en OFF ExtraJga la manguersremo_ la abrazadera que la sujeta NOTk Laabrazaderade la manguerano es reutilizable Deberacomprarseuna nueva abrazadera ver Is lists de parlesdel manualo compre una abrazaderaestandaren cualquier comercio de fetreterfa 5 Desenrosquela v_Jvula reguladors gireen sentido antihorado utilizandouna ILave tubular Asegt_e que e_disco de lav_Jvulase muevalibrement...

Page 41: ...do LinaI_averegLilable extraiga el manSmetro de presiSn externa y la conexiSn rapida del regulador 4 Extraiga el regulador 5 Aplique cinta selladora de caSerias sobre el niple de_tubo vertical 6 Ensamble el regulador y ori_ntelo de acuerdo a Io mostrado 7 Reaplique sellador de caSerias al man6metro de presiSn extema y a la conexi6n rapida 8 Rearme el manSmetro de presi6n de salida y el conector ra...

Page 42: ...de seguridad 6 Drene el agua del tanque de aire abriendo la valvula de drenaje ubicada en el rondo del tanque Riesgo de Explosibn El agua se condensa dentro del tanque de aire Si no se drene ella corroera debilitando la paredes del tenque de aire originando un rieego de ruptura de eus paredee 7 Una vez que el agua haya sido drenada cierre la valvula de drenaje NOTA Si la v lvula de drenaje estuvie...

Page 43: ...do alto Las conexiones de los tubos no estAn suficientemente ajustadas Tanque de aire defectuoso Mueva la palanca On Auto Off a la posici6n OFF si el equipo no corta contacte a un t_cnico calificado para el servicio Contacte a un t_cnico de ervicio calificado Ajuste las conexiones en as que el aire puede ser escuchado escap ndose Verifique as conexiones con soluoidn jabonosa y agua NO SOBREAJUSTE ...

Page 44: ...hubiese una caida excesiva de presion durante el uso del aooesorio ajuste el regulador de aouerdo alas instrucciones de la secci6n Operaci6n NOTA Ajuste la presidn regulada bajo condiciones de flujo rnientras se est_ usando el accesorio Disminuya la cantidad de uso de mire Vedfique el requerimiento de mire del accesorio Si es mayor que SCFM o la presi6n suministrada pot su compresor de mire se neo...

Page 45: ...co No useun fusibleo interruptorautom_ico con valoresque excedan los sepecificados papala rarnade su circuito Verifique el uso del fusible adecuado Debe usarse un fusible de acci6n retardada Verifique la existencia de problemas con el bajo voltaje Verifique la extensi6n del conductor el6ctdco Desconecte los otros artefactos el6ctdcos del circuito u opere el compresor en su ramal de circuito corres...

Page 46: ...D30052 46 SP ...

Page 47: ... per hater una compra inteligente Su nueva unidad Craftsman est diseffada y fabricada para afros de operaci6n confiable pero come todos los productos de ca_idad podrian requirir reparaciones de vez en cuando Ahi es cuando e_Contrato de Protecc 6n para Reparac ones le puede ahorrar dinero y motestias Cornpre ahora un Contrato de Protecci6n para Reparaciones y prot_jase contra apuros y gastos inespe...

Page 48: ...ike vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 600 486 1222 Anytime dayornight U S A on_y www sears com To purchase a protection agreement U S A or maintenance agreement Canada ona productserviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaciSn Au Canada pour service en fran_ ais a demicUio y para ...

Reviews: