background image

Summary of Contents for 919.167242

Page 1: ...ty Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman D30085 Rev 4 9 3 04 ...

Page 2: ...ompressor fails due to a defect in material or workmanship within one year from the date of purchase Sears will at its option repair or replace it free of charge Contact your nearest Sears Service Center 1 800 4 MY HOMP to arrange for repair or return the Air Compressor to the place of purchase for replacement If this Air Compressor is used for commercial or rental purposes this warranty applies f...

Page 3: ...ous injury _lndicates a potentially hazardous situation which if not avoided _ result in minor or moderate injury _Used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to caus...

Page 4: ... length of hose explosion may be required Store flammable materials in a secure location away from compressor Restricting any of the compressor ventilation openings will cause serious overheating and could cause fire Unattended operation of this product could result in personal injury or property damage To reduce the risk of fire do not allow the compressor to operate unattended Never place object...

Page 5: ...tank or its attachments The tank is designed to withstand specific operating pressures Never make adjustments or parts substitutions to alter the factory set operating pressures For essential control of air pressure you must install a pressure regulator and pressure gauge to the air outlet if not equipped of your compressor Follow the equipment manufacturers recommendation and never exceed the max...

Page 6: ...ge and adequate fuse 3rotection I V YJ I tm WARNING Risk of Breathing What Could Happen How To Prevent It The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover insect...

Page 7: ... or covers which are damaged or come into contact with you or your removed clothing Attempting to operate compressor with Any repairs required on this product damaged or missing parts or attempting should be performed by authorized to repair compressor with protective service center personnel shrouds removed can expose you to moving parts and can result in serious injury I V YJ I 1m WARNING Risk o...

Page 8: ...operation and controls of the air compressor Keep operating area clear of all persons pets and obstacles Keep children away from the air compressor at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a fire extinguisher Do not operate machine with missi...

Page 9: ... to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet This unit is capable of powering the following Accessories The accessories are available through t...

Page 10: ...nstallation easier Remove handle grip from soapy water and slide onto handle 2 Slide handle through holes in compressor saddle onto tabs Secure with screws one on each side Compressor Saddle It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip over 3 Install one shoulder bolt and one nut for each wheel Tighten...

Page 11: ...lug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local codes and ordinances 2 Make sure the outlet being used has the same configurati...

Page 12: ...ge and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Unsafe Operation Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply to circuit must comply with the National Electrical Code 2 Circuit is not used to supply any other electrical needs 3 Extension cords comply with s...

Page 13: ...ut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting Outlet Pressure Gauge The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator This pressure is controlled by the regulator and is always less than ...

Page 14: ...ever to OFF Before Starting Break in Procedure Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it cli...

Page 15: ...Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 2 Pull the regulator knob out and turn clock...

Page 16: ...operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF and unplug unit 2 Pull the regulator knob out and turn counterclockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approxi...

Page 17: ...nance section 2 Set the On Auto Off lever to OFF and unplug unit 3 Loosen the nut on the outlet tube and move the outlet tube to the side 4 5 Unscrew the check valve turn counterclockwise using a socket wrench Make sure the valve disc moves freely inside the check valve and the spring holds the disc in the upper closed position The check valve may be cleaned with a solvent such as paint and varnis...

Page 18: ... pages and perform scheduled maintenance as necessary 2 Set the On Auto Off lever to OFF and unplug unit 3 Turn the regulator counterclockwise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve o...

Page 19: ...tings are not tight enough Defective air tank Leaking seal Possible defect in safety valve Possible defect in safety valve Knocking Noise CORRECTION Move On Auto Off lever to the OFF position if the outfit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overt...

Page 20: ...leaks Damaged regulator Damaged regulator CORRECTION If there is an excessive amount of pressure drop when the accessory is used adjust the regulator following the instructions in the Description of Operation paragraph in the Operation Section NOTE Adjust the regulated pressure under flow conditions while accessory is being used Decrease amount of air usage Check the accessory air requirement If i...

Page 21: ...specified for your particular branch circuit Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Check the extension cord length or gauge Loose electrical connections Faulty motor Check wiring connection inside terminal box Have check...

Page 22: ...Air Compressor Model Number 919 167242 10 29_ 28 _27 _6 22 D30085 22 ENG ...

Page 23: ... LA 3069 27 D30077 28 SSF 621 29 D23627 30 D25730 Description Air Receiver 15 Gal Drain Valve Wheel 9 2 Shoulder Bolt 2 Nut Hex 3 8 16 UNC 2 Handle Screw 10 16 x 1 00 2 Molded Foot Bumper Pressure Switch Power Cord Assembly Standpipe Nipple 1 4 18 NPT x 2 50 Regulator Gauge Left Hand Gauge Right Hand Quick Connect Nut Sleeve Check Valve Safety Valve Isolator 4 Label Drain Tank Label Warning Label ...

Page 24: ...I_lJ Lv4 d I m V_ _ dJ _ Air Compressor Model Number 919 167242 23 5 20 I0 Torque 26o32 ft qbs 2_ 2 315_385 in 4bs 16 15 Torque D30085 24 ENG ...

Page 25: ...0 9 x 50 5 Screw 8 32 x 375 344 Pump Isolator 5 Timing Belt Screw 10 24 x 875 Hex Washer 4 Shroud right Outlet Tube Cylinder Head Head Gasket Kit Clamp Hose Valve Plate Assembly Cylinder Sleeve Shroud Ring Support Handle X 4 Not Illustated KK 4949 Isolator Kit KK 4929 Fastener Kit KK 4964 Connecting Rod Kit D30324 Ring Kit Z A04647 Sub Pump Assembly D30085 Operators Manual A00765 Motor Cord REPLAC...

Page 26: ...sor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra Sears a su opci6n Io reparara o reemplazara sin costo alguno Comuniquese con el Centre de Servicio Sears mas cercano 1 800 4 MY HOME para coordinar su reparaci6n o devuelva el compresor de aire al lugar donde Io compr6 para que Io cambien Si este compresor de aire se usase con fines ...

Page 27: ...s o moderadas t Usadosinelsimbolo de seguridad de alerta indica una situaci6n potencialmente riesgosa la que si no es evitada podrfa causar da_es en la propiedada I_vfl To in IV_ _ _ in Hi _ II _ In d Lu _ o _ I I _ _uJ tl 7_ _ _ Algunos tipos de aserrin creados por maquinas electricas de lijado aserrado amolado perforado u otras actividades de la construcci6n contienen rnateriales quimicos conoci...

Page 28: ... incendio no permita que el compresor opere desatendido c6mo prevenirlo opere siempre el compresor snun sector bien ventilado y libre de materiales combustibles gasolina o emanaciones de solvente En un Area de rociado de materiales infiamables ubique al compresor por Io menes a 6 1m 20 pies de distancia del _rea de rociado Podria requerirse una extensi6n de la manguera Almacene los materiales infl...

Page 29: ...rramientas neumaticas pistolas rociadoras accesorios activades por aire cubiertas y otros objetos inflables puede causar su explosibn o ser arrojados pudiendo ocasionar serias lesiones Para un control esencial de la presion debe usted instalar un regulador y un medidor de presibn a la salida del airs de su compresor Si no estuviese equipade Siga las recomendacienes de los fabricantes de su equipo ...

Page 30: ...a a tierra Id l D ADVERTENClA Riesgo de Inhalaci6n I_1 qu_ puede occurrir El aire comprimido proveniente del compresor no es sano para respirar El chorro de aim puede contener mon6xido de carbono_ vapores toxicos o particulas s61idas provenientes del tanque La inhalaci6n de dichos contaminantes puede Ilegar a causar serias lesiones o la muerte El rociado de materiales tales como pintura solventes ...

Page 31: ...rtas removidas o daSadas eeriae lesiones si elias eetraran en contacto con usted o sus ropas Intentar eperar el compresor con sus Cualquier reparaci6n requerida per este partes daSadas o faltantes o la reparaci6n prodacto debe set efectuada per personal del cempreeor con sue protecciones autorizado de los servicentres removidas puede exponerlo a usted a partee movibles que podrian resultar en lesi...

Page 32: ... del compresor de aire Mantenga libre la zona de operaciones de persona alguna animales domesticos y obstaculos Mantenga alejados a los niSos del compresor de aire en todo momento No opere el producto cuando se encuentre fatigado o bajo la influencia del alcohol o drogas Est_ alerta en todo momento Jam_s altere los elementos de seguridad de este producto Equipe la zona de operaciones con un exting...

Page 33: ...ciende y comienza a funcionar la presi6n de aire en el tanque comienza a aumentar Aumenta hasta un valor de presi6n alto fijado en fAbrica antes de que el motor autom_ticamente se apague protegiendo a su tanque de aire de presiones mAs altas que su capacidad La presi6n alta a la cual el motor se apaga se llama presi6n mAxima de corte Ramal Circuito el6ctrico que transpor_a electricidad desde el pa...

Page 34: ...cilla Extraiga el mango de agarre de la soluci6n jabonosa y deslfcelo sobre la manija 2 Deslice el mango a trav6s de los orificios sobre el montante del compresor hasta sus lengLietas AsegOrelo con tornillos poniendo uno de cada lado _ Ser_i necesario sujetar o soportar un lado del equipo cuando se instalen las ruedas porque el compresor tendra tendencia a volcarse 3 Instale un bul6n de tope y una...

Page 35: ...r utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los cddigos y ordenanzas locales El cable que acompafia a esta unidad tiene una espiga para conexi6n a tierra Esta DEBE ser utilizada con un tomacorriente conectado a tierra IMPORTANTE El tomacorriente que serA utilizado deberA haber sido conectado a tierra conforme a todos los c6digos locales y orden...

Page 36: ...rotecci6n del voltaje y del circuito Acerca del voltaje y la minima cantidad de circuitos requeridos refi ase al cuadro de especificaciones Riesgo de Operacibn Lasegura Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a trav6s de los ramales del circuito sea de 15 A 2 Que el circuito no sea utiliz...

Page 37: ... dejara de cortar el suministro de presi6n del compresor conforme a los valores prefijados para la presi6n de corte la v_lvula de seguridad proteger_ contra la presi6n elevada saltando de acuerdo a los valores prefijados en f_brica ligeramente superiores a los de presi6n de corte de la Ilave interruptora Manbmetro para controlar la presibn de salida Este man6metro indicar_ la presi6n de aire dispo...

Page 38: ...o _ Riesgo de Operacibn Insegura Si las siguientes instrucciones no fuesen seguidas estrictamente podr_n ocurrir serios daSos Este procedimiento es necesario antes de poner en servicio al compresor de aire y cuando la valvula reguladora o la bomba completa del compresor haya sido reemplazada 1 AsegQreseque la palanca On Auto Off este en la posici6n OFF NOTA Tire del acoplamiento hacia atras hasta ...

Page 39: ... ser la causa de riesgo de explosi6n Verifique los valores de maxima presi6n dados pot el fabricante de las herramientas neumaticas y los accesorios La presi6n de salida del regulador jamas debe exceder los valores de maxima presi6n especificados C6mo poner en marcha 1 Mueva la palanca On Auto Off a la posicidn AUTO y deje que se incremente la presi6n del tanque El motor se detendra una vez alcanz...

Page 40: ... no trabajara c6modamente deber_ ser reemplazada por el mismo tipo de v_lvula C6mo drenar el tanque 1 Apagar la unidad colocando el interruptor en On Auto OFF en OFF 2 Tire de la perilla del regulador y gire en sentido contrario alas agujas de reloj para establecer la salida de presi6n en cero 3 Remueva la herramienta neum_tica o el accesorio 4 Tire del aro de la v_lvula de seguridad dejando purga...

Page 41: ...agar la unidad colocando el interruptor en On Auto OFF en OFF 3 Afloje la tuerca de la salida del tubo y mu_vala hacia el costado Desenrosque la v41vulareguladora gire en sentido antihorario utilizando una Ilave tubular Aseg0rese que el disco de la valvula se mueva libremente dentro de la v lvula reguladora y que el resorte sujete al disco en posici6n erguida y cerrada La v4lvula reguladora puede ...

Page 42: ...traiga el regulador 5 Aplique cinta selladora de cafierias sobre el niple 6 Ensamble el regulador y ori_ntelo de acuerdo a Io mostrado NOTA La flecha indica el sentido del flujo del aire AsegOrese que este apuntando a la direcci6n en la que fluye el aire 7 8 Reaplique sellador de cafierfas al man6metro de presi6n externa y a la conexi6n r_pida Rearme el man6metro de presi6n de salida y el conector...

Page 43: ...a de seguridad 6 Drene el agua del tanque de aire abriendo la vAIvula de drenaje ubicada en el fondo del tanque Riesgo de Explosi6n El agua se condensa dentro del tanque de aire Si no se drena ella corroera debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus paredes 7 Una vez que el agua haya sido drenada cierre la vAIvula de drenaje NOTA Si la vAIvula de drenaje estuv...

Page 44: ...de presi6n de cofce esta calibrado demasiado alto Las conexiones de los tubos no estAn suficientemente ajustadas Tanque de aire defectuoso P_rdida en el sellado CORRECCION Mueva la palanca On Auto Off a la posici6n OFF si el equipo no corta contacte a un t_cnico calificado para el servicio Contacte a un tecnico de servicio calificado Ajuste las conexiones en las que el aire puede ser escuchado esc...

Page 45: ...o Orificio en la manguera VAIvula reguladora restringida Perdida de aire Regulador dafiado Regulador dafiado CORRECClON Si hubiese una caida excesiva de presi6n durante el uso del accesorio ajuste el regulador de acuerdo alas instrucciones de la secci6n Operaci6n NOTA Ajuste la presi6n regulada bajo condiciones de flujo mientras se este usando el accesorio Disminuya la cantidad de uso de aire Veri...

Page 46: ...co No use unfusible o interruptorautomatico con valores que excedan los especificados para la rama de su circuito Verifique el uso del fusible adecuado Debe usarse un fusible de accidn retardada Verifique la existencia de problemas con el bajo voltaje Verifique la extensi6n del conductor electrico Desconecte los otros artefactos electricos del circuito u opere el compresor en su ramal de circuito ...

Page 47: ...or hacer una compra intefigente Su nueva unidad Craftsman esta diseflada y fabricada para aflos de operacion confiable pero como todos los produetos de calidad podrian requidr reparaciones de vez en cuando Ahi es cuando el Contrato de Proteccion para Reparaciones le puede ahorrar dinero y molestias Compre ahera un Contrate de Proteccidn para Reparaciones y protejase contra apuros y gastos inespera...

Page 48: ...like vacuums lawn equipment and electronics call or go on line for the nearest Sears Parts and Repair Center 1 800 488 1222 Anytime day or night U S A only www sears com To purchase a protectionagreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 u s _ 1 800 361 6665 Canada Parapedirserviciode reparaci6n adomicilio y paraordenarpiezas Au Canadapourserviceen...