background image

7- ENG

D28409

HOW TO PREVENT IT

WHAT CAN HAPPEN

WARNING: RISK OF BURNS

Touching exposed metal 

such as the

compressor head or outlet tubes,

can

result in serious burns.

Never touch any exposed metal parts
on compressor 

during or immediately

after operation. 

Compressor will remain

hot 

for several minutes after operation.

Do not 

reach around protective shrouds

or 

attempt maintenance until unit has

been allowed to cool.

HOW TO PREVENT IT

WHAT CAN HAPPEN

WARNING: RISK FROM MOVING PARTS

Never operate the compressor with
guards 

or covers which are

damaged or

removed.

Moving parts 

such as the pulley, flywheel,

and belt

can cause serious injury 

if they

com into contact with you or your
clothing.

HAZARD

HAZARD

Any

repairs 

required on this product

should be performed by authorized
service center personnel.

Attempting to operate

compressor 

with

damaged or missing parts

or attempting

to repair compressor with protective
shrouds removed can expose you to
moving parts and 

can result in serious

injury.

HOW TO PREVENT IT

WHAT CAN HAPPEN

WARNING: RISK OF SERIOUS INJURY OR PROPERTY
DAMAGE WHEN TRANSPORTING COMPRESSOR

Oil can leak or spill

and could result in

fire or breathing hazard; serious injury or
death can result.  Oil leaks will damage
carpet, paint or other surfaces in vehicles
or trailers.

Always 

place compressor on a

protective mat when transporting

to

protect against damage to vehicle from
leaks. Remove compressor from vehicle
immediately upon arrival at your
destination.

(Fire, Inhalation, Damage to Vehicle Surfaces)

HAZARD

WARNING: RISK OF FALLING

HAZARD

HOW TO PREVENT IT

WHAT CAN HAPPEN

A portable 

compressor can fall

from a table,

workbench or roof

causing damage to the

compressor and could result in serious
injury or death to the operator.

Always 

operate compressor in a stable secure

position

to prevent accidental movement of the

unit. 

Never operate compressor on a roof or

other elevated position. Use additional air
hose to reach high locations.

Summary of Contents for 919.167362

Page 1: ...ation Maintenance Service and Adjustments Troubleshooting Repair Parts Model No 919 167362 CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60179 U S A Visit our Craftsman website www sears com craftsman D28409 Rev 0 1 22 03 ...

Page 2: ...r compressor is used for commercial or rental purposes the warranty will apply for ninety days from the date of purchase This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 TABLE OF CONTENTS WARRANTY WARRANTY 2 SPECIFICATION CHART 3 SAFETY GUIDELINES 3 8 GLOSSARY 9 ACCESSORIES 9 DUTY CYC...

Page 3: ... this information we use the symbols below Please read the manual and pay attention to these sections IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints c...

Page 4: ...property damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent vapors If spraying flammable materials locate compressor at least 20 feet away from spray area An additional length of hose may be required Store flammable materials in a secure location away from comp...

Page 5: ...pressor Failure to properly drain condensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components which control tank pressure Never drill into weld or make any modifications to the tank or its attachments Excessive vibration can weaken the air tank and cause ru...

Page 6: ...h the compressor is connected provides proper electrical grounding correct voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the tank Breathing these contaminants can cause serious injury or death Sprayed materials such as paint paint solvents paint remover ...

Page 7: ... to repair compressor with protective shrouds removed can expose you to moving parts and can result in serious injury HOW TO PREVENT IT WHAT CAN HAPPEN WARNING RISK OF SERIOUS INJURY OR PROPERTY DAMAGE WHEN TRANSPORTING COMPRESSOR Oil can leak or spill and could result in fire or breathing hazard serious injury or death can result Oil leaks will damage carpet paint or other surfaces in vehicles or...

Page 8: ...rsons pets and obstacles Keep children away from the air compressor at all times Do not operate the product when fatigued or under the influence of alcohol or drugs Stay alert at all times Never defeat the safety features of this product Equip area of operation with a fire extinguisher Do not operate machine with missing broken or unauthorized parts Unsafe operation of your air compressor could le...

Page 9: ...ressure at which the motor automatically restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor automatically shuts off protecting your air tank from pressure higher than its capacity The high pressure at which the motor shuts off is called cut out p...

Page 10: ...ng wire with an appropriate grounding plug see following illustrations The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This plug MUST be used with a grounded outlet IMPORTANT The outlet being used must be installed and grounded in accordance with all local cod...

Page 11: ... Circuit Protection Refer to the Parts Manual for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage supply through branch circuit is 15 amps 2 Circuit is not used to supply any other electrical needs lights appliances etc 3 Extension cords comply with specifications 4 Circuit is equipped wit...

Page 12: ...itch and OFF to remove power at the end of each use Pressure Switch The pressure switch automatically starts the motor when the air tank pressure drops below the factory set cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve w...

Page 13: ...ds No air should be heard leaking when the motor is running or unit reaches cut out pressure Before First Start up Break in Procedure Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced 1 Make sure the On Auto Off le...

Page 14: ...er to OFF and close air regulator 2 Pull regulator knob out turn counterclockwise until it stops Push knob in to lock in place 3 Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket 5 Run the compressor for 15 minutes Make sure the drain valve is open and there is minimal air pressure build up in tank 6 A...

Page 15: ... that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob out and turn counter clockwise to set the outlet pressure to zero 3 Remove the air tool or accessory 4 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is...

Page 16: ...ce you may be exposed to voltage sources compressed air or moving parts Personal injuries can occur Before performing any Maintenance or repair unplug the compressor and bleed off all air pressure ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN In closed position disc is visible In open position nothing is visible Screwdriver To Replace or Clean Che...

Page 17: ...e and quick connect Orient outlet pressure gauge to read correctly Tighten quick connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the outlet pressure gauge and quick connect if equipped from the regulator 4 Remove the regulator 5 Apply pipe sealant tape to the nipple Nipple Outlet Pressure Gauge Qu...

Page 18: ...proximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank causing a risk of air tank rupture 7 After the water has been drained close the drain or drain valve NOTE If drain valve is plugged release all air pressure The valve can then be removed clean...

Page 19: ...h Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pressure switch release valve Contact a Trained Service Technician Air leaks in air tank or at air tank welds Defective air tank Air tank must be replaced Do not repair the leak Do not drill into weld or otherwise ...

Page 20: ... accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace...

Page 21: ...Check for proper fuse You should use a time delay fuse Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Have checked by a Trained Service Technician Fuse blown circuit breaker tripped Extension cord is wrong length or gauge Loose electrical connections Faulty motor Check the extension ...

Page 22: ...GRAM Air Compressor Model Number 919 167362 4 10 11 Torque 9 12 ft lbs 36 34 33 32 31 37 38 24 39 35 43 11 25 23 21 44 5 16 18 20 22 17 21 46 15 14 13 12 8 9 7 6 48 45 42 Torque Snug Torque Snug Torque 60 75 in lbs Torque 50 60 in lbs ...

Page 23: ...N Screw Self Tapping 10 x 5 8 2 used 21 SSF 3156 Scew 10 9 x 50 2 used 22 AC 0400 Shroud Front 23 AC 0397 Guard Fan 24 D28391 Pressure Relief Tube 25 AC 0430 Drain Valve 31 D20114 Safety Valve 175 PSI 32 SS 2071 Nipple 1 4 18 NPT x 1 5 33 D20643 Regulator 34 D20675 Quick Connect 1 4 NPT 35 D26615 Power Cord Assembly 36 Z D21855 Gauge 2 OD 200PSI 1 8 NPT 2 used 37 SSP 6021 Bushing Reducer 1 8 1 4 N...

Page 24: ...24 ENG D28409 PUMP DIAGRAM Air Compressor Model Number 919 167362 84 85 83 82 81 80 78 70 72 73 74 76 86 88 89 79 4 79 2 79 3 79 87 ...

Page 25: ...ssion Ring 79 3 ACG 29 Connecting Rod Cap x 79 4 SSF 3158 1 Screw 10 24 x 75 T25 x 80 SSG 8156 O Ring 81 AC 0032 Valve Plate Assembly 82 ACG 45 O Ring 83 AC 0037 Head 84 SSF 589 Stud 1 4 20 x 1 125 2 used 85 SSF 927 Screw 1 4 20 x 1 125 THD 2 used 86 CAC 1173 1 Muffler Intake 87 DAC 142 Screen Filter 88 DAC 143 Filter Intake 89 DAC 144 Fastener Intake Filter 2 used Not Illustrated D28409 Owners Ma...

Page 26: ...ire fallara por defectos en materiales o mano de obra dentro del lapso de un año a partir de la fecha de su compra DEVUÉLVALO AL CENTRO DE REPARACIONES SEARS MAS CERCANO DENTRO DE LOS ESTADOS UNIDOS Y SEARS LO REPARARÁ LIBRE DE CARGO Si se hubiese comprado a Orchard Supply Hardware devuélvalo al comercio Orchard más cercano y Orchard lo reparará libre de cargo Si este compresor de aire fuese utili...

Page 27: ...o de esta información hemos utilizado los símbolos mostrados abajo Sírvase leer el manual y prestar atención a dichas secciones IMPORTANTES INSTRUCCIONES DE SEGURIDAD Algunos tipos de aserrín creados por máquinas eléctricas de lijado aserrado amolado perforado u otras actividades de la construcción contienen materiales químicos conocidos en el Estado de California como causantes de cáncer defectos...

Page 28: ...o daños a la propiedad Para reducir el riesgo de incendio no permita que el compresor opere desatendido Manténgase siempre alerta cada vez que el producto este funcionando Desconecte siempre el suministro eléctrico moviendo la palanca conmutadora de presión a la posición de apagado off y drene el tanque diariamente o después de cada uso Opere siempre el compresor en un sector bien ventilado y libr...

Page 29: ...para las herramientas neumáticas pistolas rociadoras accesorios activados por aire cubiertas y otros objetos inflables puede causar su explosión o ser arrojados pudiendo ocasionar serias lesiones PELIGRO ADVERTENCIA RIESGO DE OBJETOS ARROJADOS POR EL AIRE El chorro de aire comprimido puede causar daños sobre los tejidos blandos de la piel expuesta y puede propulsar suciedad astillas partículas sue...

Page 30: ...iones para la puesta a tierra Cualquier conexión eléctrica o reparación requerida por este producto debe ser efectuada por personal autorizado de los servicentros de acuerdo a los códigos eléctricos nacionales y locales Asegúrese que el circuito eléctrico al cual está conectado el compresor suministra apropiada conexión a tierra tensión correcta y una adecuada protección de fusibles El aire compri...

Page 31: ...a reparación del compresor con sus protecciones removidas puede exponerlo a usted a partes movibles que podrían resultar en lesiones serias PELIGRO ADVERTENCIA RIESGO DE DAÑOS A LA PROPIEDAD AL TRANSPORTAR EL COMPRESOR el aceite puede derramarse y ello podría resultar en serias lesiones o la muerte debido al riesgo de incendio o inhalación El derrame de aceite daña alfombras pinturas u otras super...

Page 32: ...odos de operación y control del compresor de aire Mantenga libre la zona de operaciones de persona alguna animales domésticos y obstáculos Mantenga alejados a los niños del coxmpresor de aire en todo momento No opere el producto cuando se encuentre fatigado o bajo la influencia del alcohol o drogas Esté alerta en todo momento Jamás altere los elementos de seguridad de este producto Equipe la zona ...

Page 33: ...riptos por los laboratorios dedicados a la certificación de la seguridad Presión mínima de corte Cuando el motor está apagado la presión del tanque de aire baja a medida que usted continúa usando su accesorio Cuando la presión del tanque baja al valor fijado en fábrica como punto bajo el motor volverá a arrancar automáticamente La presión baja a la cual el motor arranca automáticamente se llama pr...

Page 34: ...be estar adecuadamente conectado a tierra El compresor portátil de aire está equipado con un cable que tiene un conductor destinado a tierra con una espiga apropiada para su conexión ver las siguientes ilustraciones El enchufe debe ser utilizado con un toma corriente que haya sido instalado y conectado a tierra de acuerdo a todos los códigos y ordenanzas locales 1 El cable que acompaña a esta unid...

Page 35: ...USE 14 NI 16 AWG Protección del voltaje y del circuito Acerca del voltaje y la mínima cantidad de circuitos requeridos refiérase al Manual de piezas Ciertos compresores de aire pueden ser operados en un circuito de 15 A siempre que se cumplan las siguientes condiciones 1 Que el voltaje suministrado a través de los ramales del circuito sea de 15 A 2 Que el circuito no sea utilizado para alimentar n...

Page 36: ... energía eléctrica al término del uso Interruptor de presión El interruptor de presión permite el arranque automático del motor cuando la presión del tanque disminuye por debajo del valor de la presión de conexión regulada en fábrica El motor se detendrá cuando la presión del tanque alcance los valores de presión de corte regulado en fábrica para su desconexión Válvula de seguridad Si el interrupt...

Page 37: ...canzó la presión de corte Antes de poner en marcha Procedimiento para el asentamiento Si las siguientes instrucciones no fuesen seguidas estrictamente podrán ocurrir serios daños Este procedimiento es necesario antes de poner en servicio al compresor de aire y cuando la válvula reguladora o la bomba completa del compresor haya sido reemplazada 1 Asegúrese que la palanca On Auto Off esté en la posi...

Page 38: ... marcha 1 Coloque el interruptor On Auto Off en la posición OFF y cierre el regulador de aire 2 Tire de la perilla del regulador gire en sentido antihorario hasta el límite Empuje la perilla hasta su posición blocante 3 Conecte la manguera y accesorios NOTA Tanto la manguera como los accesorios requerirán un enchufe de conexión rápida si la salida del aire está equipada con un zócalo de conexión r...

Page 39: ...por el mismo tipo de válvula Cómo drenar el tanque 1 Coloque la palanca On Auto Off en la posición OFF 2 Tire de la perilla del regulador y gire en sentido contrario a las agujas de reloj para establecer la salida de presión en cero 3 Remueva la herramienta neumática o el accesorio 4 Tire del aro de la válvula de seguridad dejando purgar el aire del tanque hasta que este reduzca su presión aproxim...

Page 40: ...cla automáticamente en cuanto la energía eléctrica es conectada Al efectuar el mantenimiento usted quedará expuesto a tensión viva aire comprimido o partes en movimiento Debido a tales circunstancias podrían ocurrirle lesiones personales Antes de efectuar mantenimiento o reparación alguna desenchufe el compresor y purgue cualquier presión de aire TODO TIPO DE MANTENIMIENTO Y OPERACIONES DE REPARAC...

Page 41: ...do Oriente el manómetro de salida para permitir su lectura correctamente Ajuste las conexiones con a llav Para reemplazar el regulador 1 Libere toda la presión del aire del tanque Vea Drenaje del tanque en la sección Mantenimiento 2 Desenchufe el equipo 3 Usando una llave de tuercas ajustable retire el medidor de salida de presión y la conexión rápida del regulador si la tiene 4 Extraiga el regula...

Page 42: ...el anillo de la válvula de seguridad 6 Drene el agua del tanque de aire abriendo la válvula de drenaje ubicada en el fondo del tanque El agua se condensa dentro del tanque de aire Si no se drena ella corroerá debilitando la paredes del tanque de aire originando un riesgo de ruptura de sus paredes 7 Una vez que el agua haya sido drenada cierre la válvula de drenaje NOTA Si la válvula de drenaje est...

Page 43: ...n las que el aire puede ser escuchado escapándose Verifique las conexiones con solución jabonosa y agua NO SOBREAJUSTE Las conexiones pierden aire Pérdida de presión de aire en el interruptor de la válvula aliviadora Un interruptor de presión defectuoso libera la válvula Contacte a un técnico calificado en servicio Pérdida de aire en el tanque de aire o en las soldaduras del tanque de aire Tanque ...

Page 44: ... aire se necesita un compresor de mayor capacidad Verifique y reemplace si fuese necesario Extraiga limpie o reemplace Ajuste las conexiones Regulador dañado Reemplace El regulador tiene una fuga continua de aire El regulador no cierra la salida del aire Regulador dañado Reemplace La lectura de la presión sobre un manómetro si viene equipado con éste desciende cuando se utiliza un accesorio Es nor...

Page 45: ...e su circuito Verifique el uso del fusible adecuado Debe usarse un fusible de acción retardada Verifique la existencia de problemas con el bajo voltaje Verifique la extensión del conductor eléctrico Desconecte los otros artefactos eléctricos del circuito u opere el compresor en su ramal de circuito correspondiente El cable de extensión eléctrica tiene una longitud o calibre erróneo Verifique la ex...

Page 46: ...46 SP D28409 NOTES NOTAS ...

Page 47: ...47 SP D28409 NOTES NOTAS ...

Page 48: ...epair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME Anytime day or night 1 800 469 4663 ...

Reviews: