background image

Summary of Contents for 919.167780

Page 1: ...ety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Espahol CAUTION Read the Safety Guidelines and All Instructions Carefully Before Operating Sears Roebuck and Co Hoffman Estates IL 60170 U S A Visit our Craftsman website www sears com craftsman D22130 Rev 1 11 8 01 ...

Page 2: ...r 13 SERVICE AND ADJUSTMENTS 14 15 To Replace or Clean Check Valve 14 To Replace Regulator 15 STORAGE 15 TROUBLESHOOTING GUIDE 16 18 ESPA_iOL 19 24 HOW TO ORDER REPAIR PARTS Back Cover FULL ONE YEAR WARRANTY AIR COMPRESSOR If this air compressor fails due to a defect in material or workmanship within one year from the date of purchase RETURN IT TO THE NEAREST SEARS REPAIR CENTER THROUGHOUT THE UNI...

Page 3: ...NTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK iF ELECTRICAL SPARKS FROM COMPRESSOR COME iNTO CONTACT WiTH FLAMMABLE VAPORS THEY MAY iGNiTE CAUSING FiRE OR EXPLOSION RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE FIRE UNATTENDED OPERATION OF THIS PRODUCT COULD RESULT iN PERSONAL INJURY OR PROPERTY DAM AGE HOW TO PREVENT IT ALWAYS OPERAT...

Page 4: ...E TANK OR ITS ATTACHMENTS THE TANK IS DESIGNED TO WITHSTAND SPECIFIC OPER ATING PRESSURES NEVER MAKE ADJUSTMENTS OR PARTS SUBSTiTUTiONS TO ALTER THE FACTORY SET OPERATING PRESSURES FOR ESSENTIAL CONTROL OF AIR PRESSURE YOU MUST iNSTALL A PRESSURE REGULATOR AND PRES SURE GAUGE TO THE AiR OUTLET iF NOT EQUIPPED OF YOUR COMPRESSOR FOLLOW THE EQUIPMENT MANUFACTURERS RECOMMENDATION AND NEVER EXCEED THE...

Page 5: ... AGE AND ADEQUATE FUSE PROTECTION RISK TO BREATHING WHAT CAN HAPPEN HOW TO PREVENT iT THE COMPRESSED AiR DIRECTLY FROM YOUR COM PRESSOR iS NOT SAFE FOR BREATHING THE AiR STREAM MAY CONTAIN CARBON MONOXIDE TOXIC VAPORS OR SOLID PARTICLES FROM THE TANK BREATHING THESE CONTAMINANTS CAN CAUSE SERIOUS iNJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOL VENTS PAINT REMOVER INSECTICIDES WEED KILLER...

Page 6: ...AIRS REQUIRED ON THIS PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL RiSK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR CAN FALL FROM A TABLE WORKBENCH OR ROOF CAUSING DAMAGE TO THE COMPRESSOR AND COULD RESULT IN SERIOUS INJURY OR DEATH TO THE OPERATOR ALWAYS OPERATE COMPRESSOR IN A STABLE SECURE POSITION TO PREVENT ACCIDENTAL MOVE MENT OF THE UNIT NEVER OP...

Page 7: ...sure at which the motor shuts off is called cut out pressure Branch Circuit Circuit carrying electricity from elec trical panel to outlet This unit is capable of powering the following Accessories The accessories are available through the current Power and Hand Tool Catalog or full line Sears stores Accessories Caulk Gun 1 2 Ratchet Reciprocating Saw In Line Filter Engine Cleaner 3 8 Ratchet Nibbl...

Page 8: ...ushed up a ramp Assemble Rubber Feet 1 Attach rubber feet with the screws provided as shown in previous figure 2 Tighten securely 3 It may be necessary to brace or support one side of the air compressor when removing the pallet because the air compressor will have a tendency to tip Carefully remove the air compressor from the pal let Assemble Wheels 1 It will be necessary to brace or support one s...

Page 9: ...ould be installed by a qualified electri clan Repairs to the cord set or plug MUST be made by a qualified electrician Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor and to prevent overheating If an extension cord must be used be sure it is a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will a...

Page 10: ...rn clockwise to increase pressure and counterclockwise to decrease pressure When the desired pressure is reached push knob in to lock in place Regulator Drain Valve The drain valve is located at the base of the air tank and is used to drain condensa tion at the end of each use Cooling System not shown This compressor con tains an advanced design cooling system At the heart of this cooling system i...

Page 11: ...or knob out turn counter clockwise until it stops Push knob in to lock in place Attach hose and accessories NOTE The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect Too much air pressure causes a hazardous risk of bursting Check the manufacturer s maximum pressure rating for air tools and accessories The regulator outlet pressure must never ex...

Page 12: ...pture or an explosion Before starting com pressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob out and turn clockwise to set the outlet pressure to zero 3 Remove the air tool or accessor...

Page 13: ... Motor The motor has an automatic reset thermal overload protector If the motor overheats for any reason the overload protector will shut off the motor The motor must be allowed to cool down before restarting The compressor will automatically restart after the motor cools If the overload protector shuts the motor off frequent ly check for a possible voltage problem Low voltage can also be suspecte...

Page 14: ...ove pressure relief tube away from check valve Unscrew the check valve turn counterclockwise using a 7 8 open end wrench Note the orienta tion for reassembly Using a screwdriver carefully push the valve disc up and down NOTE The valve disc should move freely up and down on a spring which holds the valve disc in the closed position if not the check valve needs to be cleaned or replaced Screwdriver ...

Page 15: ...d ing pages and perform scheduled maintenance as necessary 2 Set the On Auto Off lever to OFF 3 Turn the regulator counterclockwise and set the outlet pressure to zero 4 Remove the air tool or accessory 5 Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of...

Page 16: ...ressure drop to occur Move On Auto Off lever to the OFF position if the outfit does not shut off contact a Trained Service Technician Contact a Trained Service Technician Tighten fittings where air can be heard escaping Check fittings with soapy water solution DO NOT OVERTIGHTEN A defective check valve results in a constant air leak at the pressure release valve when there is pres sure in the tank...

Page 17: ...d regulator Damaged regulator CORRECTION Operate safety valve manually by pulling on ring If valve still leaks it should be replaced Remove and clean or replace Decrease amount of air usage Check the accessory air require ment If it is higher than the SCFM or pressure supplied by your air compressor you need a larger compressor Check and replace if required Remove and clean or replace Tighten fitt...

Page 18: ...gth Remove and clean or replace Check wiring connection inside pressure switch and terminal box area Have checked by a Trained Service Technician Have checked by a Trained Service Technician Do not oper ate the compressor in the paint spray area See flammable vapor warning Bleed the line by pushing the lever on the pressure switch to the off position if the valve does not open replace switch 1 Che...

Page 19: ...e la boma delcompressor de aire 30 Motor 30 SERVIClOS Y REGULAClONES 31 32 Para reemplazar o limpiar la v lvula de retenci6n 31 Para reemplazar el regulador 32 ALMACENAJE 32 GUJA DE DIAGN6STICO DE PROBLEMAS 33 35 COMO SOLICITAR PIEZAS PAPA REPAPACION contratapa GARANTJA COMPLETA POR UN AI_IO COMPRESOR DE AIRE Si este compresor de aire fallara por defectos en materiales o mano de obra dentro del la...

Page 20: ...ERRUPTOR A PRESlON Sl LAS CHISPAS ELECTRICAS PROVENIENTES DEL COMPRESOR TOMARAN CONTACTO CON EMANACIONES DE MATERIALES INFLAMABLES ELLOS PODRJAN ARDER ORIGINANDO INCENDIO O EXPLOSION RESTRINGIR CUALQUIERA DE LAS ABERTURAS DE VENTILACION CAUSARA UN SERIO RECALENTAMIENTO Y PODRJA PRODUClR UN INCENDIO DEJAR DESATENDIDO ESTE PRODUCTO MIENTRAS EL MISMO EST _ EN FUNCIONAMIENTO PUEDE RESULTAR EN LESIONES...

Page 21: ...A AL TANQUE O SUS ACCESORIOS EL TANQUE EST k DISENADO PARA RESISTIR PRESlONES OPERATIVAS ESPECiFICAS JAMAS EFECTUE AJUSTES O SUSTITUYA PARTES QUE ALTEREN LAS REGULACIONES DE PRESION ORIGINALES DE FABRICA PARA UN CONTROL ESENCIAL DE LA PRESION DEBE USTED INSTALAR UN REGULADOR Y UN MEDIDOR DE PRESION A LA SAMDA DEL AIRE DE SU COMPRESOR SI NO ESTUNIER EQUIPADO SIGA LAS RECOMENDACIONES DE LOS FABRICAN...

Page 22: ...N DE FUSIBLES RIESGO DE INHALACION _ QU_ PUEDE OCURRIR _ C6MO PREVENIRLO EL AIRE COMPRIMIDO PROVENIENTE DEL COMPRESOR NO ES SANO PARA RESPIRAR EL CRORRO DE AIRE PUEDE CONTENER MONOXIDO DE CARBONO VAPORES TOXICOS O PARTICULAS SOLIDAS PROVENIENTES DEL TANQUE LA INHALACION DE DICHOS CONTAMINANTES PUEDE LLEGAR A CAUSAR SERIAS LESIONES O LA MUERTE EL ROCIADO DE MATERIALES TALES COMO PINTURA SOLVENTES R...

Page 23: ...IDA POR ESTE PRODUCTO DEBE SER EFECTUADA POR PERSONAL AUTORIZADO DE LOS SERVlCENTROS RIESGO DE CAIDA QUE PUEDE OCURRIR COMO PREVENIRLO UN COMPRESOR PORT kTIL PUEDE CAERSE DE LA MESA EL BANCO DE TRABAJO O DEL TECHO DAI_IANDO AL COMPRESOR Y PUDIENDO RESULTAR EN SERIAS LESIONES O LA MUERTE DEL OPERADOR OPERE SIEMPRE EL COMPRESOR EN UNA POSICION ESTABLE Y SEGURA A FIN DE PREVENIR EL MOVIMIENTO ACCIDEN...

Page 24: ...o electrico que transporta electricidad desde el panel de control hasta el tomacorriente Esta unidad es suficiente para abastecer de energia el6ctrica a los siguientes accesorios Estos se encuentran disponibles a trav6s del catalogo para herramientas el6ctricas y manuales en cualquiera de los comercios que mantiene la linea completa de SEARS Aocesorios Pistola para grasa Trinquete de 3 8 Pintura p...

Page 25: ...dad debe ser levantada o empujada por una rampa Ensamble de las patas de caucho 1 Fije las patas de caucho con los tornillos provistos como se muestra en la figura previa 2 Apriete firmemente 3 Puede set necesario soportar un lado del compresor de aire cuando se retira la tarima porque el compresor de aire tendera a voltearse Retire cuidadosamente el compresor de aire de ia tari ma Ensamble de las...

Page 26: ...ificar la instalaci6n pot un electricista compe tente LA CONEXION INADECUADA A TIERRA PUEDE DETERMINAR UNA DESCARGA ELI_CTRICA No modifique el enchufe provisto Si el mismo no penetrara el tomacorriente disponible un electricista competente deber_ instalar uno apropiado La reparaci6n del cable odel enchufe DEBERA set efectuada pot un electricista competente Cables de e tensi6n el_ctrica Use extensi...

Page 27: ... y hagalo en sentido inverso para disminuirla Cuando se Iogre la presi6n desea da presione la perilla para bloquearla Switch Valvula de drenaje La valvu la de drenaje se encuentra ubicada sobre la base del tanque de aire y se usa para drenar la condensaci6n al fin drenaje de cada uso Sistema de enfriamiento no mostrado Este compresor contiene un sistema de avanzada para el control de enfri amiento...

Page 28: ...rio 7 Mueva la paianca On Auto Off a la posici6n ON AUTO El aire recibido ira Ilenando hasta el punto de corte de pre si6n y el motor se detendra El compresor estara ahora listo para ser usado Antes de cada puesta en marcha 1 Coloque el interruptor On Auto Off en la posici6n OFF y cierre el regulador de aire 2 Tire de la perilla del regulador gire en sentido antihorarie hasta el limite Empuje la p...

Page 29: ...motor tire del anillo de la valvula de seguridad para confirmar la seguridad de que la misma opera libremente si la valvula quedase trabada o no trabajara c6modamente debera set reemplazada pot el mismo tipo de valvula C6rno drenar el tanque 1 Coloque la palanca On Auto Off en la posici6n OFF 2 Tire de la perilla del regulador y gire en sentido horatio para establecer la salida de presi6n en cero ...

Page 30: ...aire Motor El motor tiene un protector de sobrecarga termico de reposici6n automatica Si el motor se sobrecalienta per alguna raz6n el protector de sobrecarga apagara el motor Debe dejar enfriar el motor antes de volverlo a arrancar El compresor arrancara automaticamente despues que se enfrie el motor Si el protector de sobrecarga apaga el motor con mucha frecuencia verifique si hay algt_n posible...

Page 31: ...6n gira_ndola hacia la izquierda usando una Ilave de boca de 7 8 Tome nora de la orientaci6n para volverla a ensamblar Usando un destornillador empuje con cuidado el disco de la valvula hacia arriba y hacia abajo NOTA El disco de la vg lvula debe moverse libremente hacia arriba y hacia abajo sobre un resorte que detiene el disco de la valvula en la posici6n cerrada Si no Io hace la valvula de rete...

Page 32: ...imiento programado de acuerdo a la necesidad 2 Coloque la palanca On Auto Off en la posici6n OFF 3 Gire el regulador en sentido antihorario y fije la presi6n de salida en cero 4 Extraiga la herramienta neumatica o el accesorio 5 Tire del anillo de la valvula de seguridad permitiendo el purgado del aire del tanque hasta que la presi6n del mismo Ilegue aproximadamente a 20 PSI Suelte el anil Io de l...

Page 33: ...a Tanque de aire defectuoso Perdida en el sellado Es normal que ocurran algunas caidas de presi6n Mueva la palanca On Auto Off a la posici6n OFF si el equipo no corta contacte a un tecnico calificado para el servicio Contacte a un tecnico de servicio calificado Ajuste las conexiones en las que el aire puede ser escuchado escapandose Verifique las conexiones con soluci6n jabonosa y agua NO SOBREAJU...

Page 34: ...Perdida de aire Filtro de entrada de aire restringido Regulador danado Regulador danado OORREOCION Opere la valvula de seguridad manual mente tirando de su anillo Si la valvula aun pierde debera set reemplazada Extraiga y limpie o reemplace Decrease amount of air usage Check the accessory air requirement If it is higher than the SCFM or pres sure supplied by your air compressor you need a larger c...

Page 35: ...del cord6n Retire y limpie o reemplace Compruebe la conexi6n de cableado dentro del interruptor de presi6n y del Area de la caja de terminales Haga inspeccionar pot un tecnico capacitado de servicio Haga inspeccionar pot un tecnico capacitado de servicio No haga funcionar el compresor en el Areade pintura pot rociado Vea la advertencia acerca de vapores inflamables Purgue la Ifnea empujando la pal...

Page 36: ... the replacement parts accessories and owner s manuals that you1 need 800t 366 do it yourself PART 6 call a m Sears _ 11 p m PartsDireet SM CST 1 800 366 7278 7 days a week HHHHHH_ www sears com partsdirect T purchase rinquire uttSearsServiceAgreement l 800 827 6655 ooSat iiiiiiiiiiiiii Pare pedir servicio de reparaci6n a domicilio Au Canada pour service en fran_ais y pare ordenar piezas con entre...

Reviews: