GROUNDING INSTRUCTIONS
RISK OF ELECTRICAL
SHOCK.
In the event of a
short circuit, grounding reduces the risk of
shock by providing an escape wire for the
electric current. This air compressor must be
properly grounded.
The portable air compressor is equipped with a cord
having a grounding wire with an appropriate ground-
ing plug (see following illustrations). The plug must be
used with an outlet that has been installed and
grounded in accordance with all local codes and ordi-
nances.
1.
The cord set and plug with this unit contains a
grounding pin. This plug MUST be used with a
grounded outlet.
IMPORTANT:
The outlet being used must be installed
and grounded in accordance with all local codes and
ordinances.
2.
Make sure the outlet being used has the same
configuration as the grounded plug.
DO NOT USE
AN ADAPTER.
See illustration.
3.
Inspect the plug and cord before each use. Do
not use if there are signs of damage.
Grounding Pin
Grounded
Outlets
Plug
INSTALLATION
HOW TO SET UP YOUR UNIT
Location of the Air Compressor
l
Locate the air compressor in a clean, dry, and well
ventilated area.
l
The air compressor should be located at least 12"
away from the wall or other obstructions that will
interfere with the flow of air.
l
The air filter and flywheel must be kept clear of
obstructions which could reduce air flow to the air
compressor.
l
The air compressor requires fresh air flow for
proper cooling.
DO NOT ALLOW THE COM-
PRESSOR TO GET WET.
4.
If these grounding instructions are not completely
understood, or if in doubt as to whether the com-
pressor is properly grounded, have the installation
checked by a qualified electrician.
IMPROPER GROUNDING
CAN RESULT IN ELEC-
TRICAL SHOCK.
Do not modify the plug provided. If it does
not fit the available outlet, a correct outlet
should be installed by a qualified electri-
cian.
Repairs to the cord set or plug MUST be
made by a qualified electrician.
Extension Cords
Use extra air hose instead of an extension cord to
avoid voltage drop and power loss to the motor, and
to prevent overheating.
If an extension cord must be used, be sure it is:
•
a 3-wire extension cord that has a 3-blade
grounding plug, and a 3-slot receptacle that will
accept the plug on the product
•
in good condition
•
no longer than 50 feet
•
12 gauge (AWG) or larger. (Wire size increases as
gauge number decreases. 10 AWG and 8 AWG
may also be used. DO NOT USE 14 OR 16
AWG.)
Voltage and Circuit Protection
Refer to the Parts Manual for the voltage and mini-
mum branch circuit requirements.
Certain air compressors can be operated on a 15 amp
circuit if the following conditions are met.
1.
Voltage supply through branch circuit is 15 amps.
2.
Circuit is not used to supply any other electrical
needs (lights, appliances, etc.).
3.
Extension cords comply with specifications.
4.
Circuit is equipped with a 15 amp circuit breaker
or 15 amp time delay fuse.
NOTE:
If compressor
is connected to a circuit protected by fuses, use
only time delay fuses. Time delay fuses should be
marked “D” in Canada and “T” in the US.
If any of the above conditions cannot be met, or if
operation of the compressor repeatedly causes inter-
ruption of the power, it may be necessary to operate it
from a 20 amp circuit. It is not necessary to change
the cord set.