TROUBLESHOOTING
Performing repairs may expose voltage sources, moving
parts or compressed air sources, moving parts or
compressed air sources. Personal injury may occur. Prior to attempting
any repairs, unplug the air compressor and bleed off all air tank air
pressure.
PROBLEM
CAUSE
CORRECTION
Hose fitting loose.
Prolonged excessive use of
air.
Hole in hose.
Air leaks.
Tighten fitting.
Decrease the amount of air
usage. Your compressor is
not large enough for the air
requirement.
Replace the hose.
Tighten fittings.
Air Leaks
Compressor is
not delivering
enough air.
16- ENG
D24483
Fuse blown, circuit breaker
tripped.
1.
Check fuse box for
blown fuse and replace
as necessary. Reset
circuit breaker. Do not
use a fuse or circuit
breaker with higher
rating than that specified
for your particular
branch circuit.
2.
Check for proper fuse.
You should be using a
“Time Delay” fuse.
3.
Check for low voltage
problem.
4.
Check the extension
cord.
5.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Motor will not
run.
Extension cord is wrong
length or gauge.
Loose electrical
connections.
Faulty motor.
Check the extension cord.
Check wiring connection
inside terminal box area.
Contact a Trained Service
Technician.
Adjustable pressure valve
not functioning.
Risk of
bursting. DO
NOT operate the compressor
if this problem exists.
Adjustable pressure valve
must be replaced.
High discharge
pressure.
Cannot be
adjusted lower.