background image

3

English

OPERATING THE SPRAYER

Filling
Fill the tank to the desired level.
1a. REMOVE PUMP: Turn handle counter-clockwise
2a. INSTALL PUMP: Turn handle clockwise until tightly sealed   
      on tank

Pressurizing
Make sure the shut-off trigger is not locked  in the “in use” 
position
1b. Push down on the handle and turn counter-clockwise to 
      unlock the handle.
2b. Pump handle in a smooth up and down motion until 
      pressure builds up.
3b. Push down on handle, turn clockwise to lock into place.

Spraying and Locking
1. Squeeze shut-off trigger to begin spraying.
2. Release shut-off trigger to stop spraying.
3. For continuous spraying, squeeze the trigger and slide  
    into locked position as shown.

Finish

1.  Depressurize

a.  Lay tank on its side with the hose outlet on the 

bottom. Direct nozzle away from face and body and 
squeeze the shut-off handle until unit stops spraying. 
This will release the pressure in the tank.

2.  Turn the pump handle counter-clockwise to remove 

pump.

3.  Empty any remaining liquid according to the product 

disposal directions.

4.  Follow cleaning instructions.

Cleaning

1.  Fill the tank with clean tap water. Replace the pump 

and tighten securely.

2.  Agitate the tank to rinse the chemicals from the tank 

and pump.

3.  Remove the pump and empty the contents according 

to the product disposal instructions.

4.  Refill the tank with clean tap water.
5.  Make sure the pump is free of dirt and debris, and 

re-install into the tank. Tighten securely.

6.  Pressurize the tank as described in the pressurizing 

section.

7.  Direct the nozzle away from yourself and squeeze the 

shut-off trigger for at least 30 seconds to clean the hose 
and shut-off.

8.  Release pressure as described in the finishing section.
9.  Remove the pump and empty contents according to 

the product disposal instructions.

10.  Repeat steps 1-9 until thoroughly cleaned.

Sprayer Storage

1.  Sprayer tank should be hung upside down, with the 

pump removed.

2.  Do not store or leave any solution in tank after use.
3.  Store in warm, dry location out of direct sunlight.
4.  Keep sprayer and all chemicals out of reach of children.

Disassembly & Reassembly

1.  Remove pump from tank.
2.  Squeeze tabs that lock cap and pull to unlock.
3.  Remove handle, lubricate o-ring as required.
4.  Replace pump cap, align tabs on pump cap and barrel, 

and push down until tabs lock into place.

1a

2a

1b

2b

3b

Summary of Contents for CMXCAFG190643

Page 1: ...es Pulvérisateur nettoyant tout usage DE 7 5 L CMXCAFG190643 INSTRUCTIONMANUAL MANUALDEINSTRUCTIONES GUIDED UTILISATION IFYOUHAVEQUESTIONSORCOMMENTS CONTACTUS SITIENEPREGUNTASOCOMENTARIOS CONTÁCTENOS POURTOUTEQUESTIONOUTOUTCOMMENTAIRE NOUSCONTACTER 1 888 331 4569 WWW CRAFTSMAN COM ...

Page 2: ...AFTSMAN En Craftsman tenemos 90 años de calidad e innovación Juntos somos fabricantes Por favor tómese un momento para leer este manual antes de operar su atomizador nuevo Es importante que comprenda las advertencias y precauciones de seguridad antes de usar su nueva compra en forma segura Merci d avoir choisi un produit CRAFTSMAN Chez Craftsman nous évoluons depuis 90 ans avec des produits de qua...

Page 3: ...h if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Used without word Indicates a safety related message NOTICE Indicates a practice not related to personal injury which i...

Page 4: ...pressor since this can create dangerous pressure level and bursting of parts resulting in serious injury Only use original or replacement pump supplied by the original manufacturer Do not store chemicals in this tank Always release pressure when sprayer is not in use and before removing pump from tank Do not stand with face or body over top of tank when pumping or loosening pump to prevent pump an...

Page 5: ...ons Cleaning 1 Fill the tank with clean tap water Replace the pump and tighten securely 2 Agitate the tank to rinse the chemicals from the tank and pump 3 Remove the pump and empty the contents according to the product disposal instructions 4 Refill the tank with clean tap water 5 Make sure the pump is free of dirt and debris and re install into the tank Tighten securely 6 Pressurize the tank as d...

Page 6: ... handle is released Shut off lock is engaged Squeeze shut off handle and disengage the lock Sprayer leaks at pump or sprayer does not build pressure 1 Dirt or debris on pump gasket or closure 2 Chipped torn swollen or defective pump gasket 3 Check valve at bottom of pump assembly 4 Inspect o ring on piston 5 Loose hose 1 Clean dirt or debris from gasket or closure 2 Remove old gasket and replace w...

Page 7: ... utiliza los siguientes símbolos y palabras de alerta de seguridad para advertirle sobre situaciones peligrosas y el riesgo de lesiones corporales o daños materiales PELIGRO Indica una situación de peligro inminente que si no se evita provocará la muerte o lesiones graves ADVERTENCIA Indica una situación de peligro potencial que si no se evita podría provocar la muerte o lesiones graves CUIDADO In...

Page 8: ...o mecánico alguno como por ejemplo un compresor de aire ya que esto puede ocasionar un nivel de presión peligroso y que las piezas estallen produciendo lesiones graves Sólo utilice la bomba original o la bomba de reemplazo que le suministre el fabricante original No almacene productos químicos en este tanque Libere siempre la presión cuando el atomizador no esté en uso y antes de quitar la bomba d...

Page 9: ...tra Finalización 1 Despresurice a Coloque el tanque de costado con la salida de la manguera en la parte inferior Dirija la boquilla en sentido contrario a usted y presione el mango de cierre hasta que la unidad deje de rociar Esto liberarà la presión del tanque 2 Gire el mango de la bomba en sentido antihorario para quitar la bomba 3 Vacíe todo el líquido restante de acuerdo con las instrucciones ...

Page 10: ... PROPÓSITO EN PARTICULAR Y EXCLUYE TODOS LOS DAÑOS INCIDENTALES O CONSECUENTES Algunos estados no permiten limitaciones sobre la duración de una garantía implícita ni la exclusión o limitación de daños incidentales o consecuentes por lo que estas limitaciones pueden no aplicarse en su caso Esta garantía le da derechos legales específicos y puede tener otros derechos que varían en ciertos estados o...

Page 11: ...omba 2 Válvula de retención de bomba astillada rasgada o dilatada 1 Limpie la válvula de retención y la superficie sellada de la válvula de la bomba 2 Reemplace la válvula de retención La manguera tiene una pérdida en el tanque 1 Manguera suelta 2 Manguera agrietada dilatada o defectuosa 1 Vuelva a insertar el conector de manguera y apriete la tuerca de la manguera 2 Reemplace el conjunto de cierr...

Page 12: ...otentiellement dangereuse qui si elle n est pas évitée pourrait entraîner des blessures légères ou modérées Si utilisé sans aucun terme Indique un message propre à la sécurité AVIS indique une pratique ne posant aucun risque de dommages corporels mais qui par contre si rien n est fait pour l éviter pourrait poser des risques de dommages matériels DESCRIPTION 1 Réservoir 2 Capuchon anti éclaboussur...

Page 13: ... vous assurant que cette derniére est bien verrouillée en place avant de soulever la pompe Ne pas utiliser de dispositif mécanique tel un compresseur d air car il pourrait créer un niveau de pression dangereux et l éclatement des pièces causant des blessures graves Utilisez uniquement la pompe d origine Ne stockez pas de produits chimiques dans ce réservoir Relâchez toujours la pression lorsque le...

Page 14: ...puyez sur la gâchette et glissez le verrou comme indiqué Finir 1 Dégagez la pression a Déposez le réservoir sur côté avec la sortie du boyau au bas Dirigez la buse loin du visage et du corps terminer la pulvérisation jusqu à ce que l appareil cesse de pulvériser Ceci dégagera la pression dans le réservoir 2 Tournez la poignée de pompe dans le sens antihoraire pour retirer la pompe 3 Disposez du re...

Page 15: ...ES DE LA QUALITÉ MARCHANDE ET L APTITUDE POUR UN BUT PARTICULIER ET EXCLUT TOUS LES DOMMAGES ACCIDENTELS OU CONSÉCUTIFS Certaines provinces ne permettent pas de limitation sur la durée de la garantie implicite ou l exclusion ou la limitation de dommages indirects alors ces limitations peuvent ne pas s appliquer à vous Cette garantie vous donne des droits légaux particuliers et vous pouvez avoir d ...

Page 16: ...uré gonflé ou défectueux 1 Réinsérer le raccord du tuyau puis serrer l écrou du tuyau 2 Remplacez l assemblage de robinet Le tuyau fuit à l arrêt Tuyau fissuré gonflé ou défectueux Remplacez le dispositif d arrêt Le pulvérisateur est difficile à pomper 1 Le joint torique du piston endommagé 2 Le joint torique du piston est sec 1 Remplacez le joint torique du piston 2 Lubrifiez la pompe tel que déc...

Reviews: