88
Code
Name
Setting Range
F5.09
X terminal trait selection
0
~
1
【
0
】
Setting the working logic of X terminal.
0: On valid
1: Off valid
Code
Name
Setting Range
F5.10
UP/DOWN setting change rate
0.01
~
50.00Hz/S
【
0.50
】
This parameter is used to determine how fast UP/DOWN setting changes.
Code
Name
Setting Range
F5.11
AI1 lower limit
0.00
~
10.00V
【
0.00V
】
F5.12
AI1 lower limit corresponding setting
-100.0
~
100.0%
【
0.0%
】
F5.13
AI1 upper limit
0.00
~
10.00V
【
10.00V
】
F5.14
AI1 upper limit corresponding setting
-100.0
~
100.0%
【
100.0%
】
F5.15
AI1 filter time constant
0.01
~
10.00S
【
0.10S
】
These parameters determine the relationship between analog input voltage and the
corresponding setting value.When the analog input voltage exceeds the range between
lower limit and upper limit,it will be regarded as the upper limit or lower limit.
The analog input All can only provide voltage input,and the range is 0V
~
10V.
For different applications,the corresponding value of 100.0% analog setting is
different.For details,please refer to description of each application.
The following illustration shows several set of conditions
.
Note: Al1 lower limit must be less or equal to Al1 upper limit.