5. Fan Assembly.

Remove hanging ball from downrod provided by 
loosening set screw on hanging ball. Lower hanging 
ball and remove stop pin and then slide hanging ball 
off of the downrod. 

[

Refer to 

diagram 1

.

]

Loosen yoke set screws and nuts at top of motor 
assembly. Remove pin and clip from motor assembly 
yoke. 

[

Refer to 

diagram 2

.

]

Tip

: To prepare for threading electrical wires through 

downrod, apply a small piece of electrical tape to the 
ends of the electrical wires--this will keep the wires 
together when threading them through the 
downrod. 

[

Refer to 

diagram 2

.

]

Determine the length of downrod you wish to use.
Thread safety cable and electrical wires through 
threaded end of downrod and pull extra wire slack 
from the upper end of the downrod. 

[

Refer to 

diagram 2

.

Thread downrod into the motor assembly yoke until 
holes for pin and clip in downrod align with holes in 
yoke--

make sure wires do not get twisted

. Re-insert pin 

and clip that were previously removed. Tighten yoke 
set screws and nuts securely. 

[

Refer to 

diagram 2

.

]

 
Slide yoke cover and canopy over downrod. 

[

Refer to 

diagram 3

.

Thread safety cable and wires through hanging ball; 
then slide hanging ball over downrod--the top of the 
downrod should be noted as having a set screw hole; 
use this hole when setting the set screw. Insert stop 
pin into top of downrod and raise hanging ball. Be 
sure stop pin aligns with slots on the inside of the 
hanging ball. Tighten set screw securely. 

[

Refer to 

diagram 4

.

]

 

WARNING

: Failure to tighten set screw completely 

could result in the fan becoming loose and possibly 
falling. 

["Fan Assembly"  continued on next page.]

NOTE

:  The important safety precautions and instructions 

appearing in the manual are not meant to cover all possible 
conditions and situations that may occur. It must be 
understood that common sense and caution are necessary 
factors in the installation and operation of this fan.

set screw

hanging ball

stop pin

diagram 2

diagram 1

diagram 3

diagram 4

canopy

motor
assembly 

downrod

downrod

electrical wiring

safety cable

yoke set
screw 
and nut

pin

clip

set screw hole

hanging

 ball

stop pin

yoke cover

Summary of Contents for MIDORO MO56

Page 1: ...rol Assembly pg 9 Automated Learning Process Activating Code pg 10 Remote Control Operation pg 10 Testing Your Fan pg 10 Troubleshooting pg 11 Warranty pg 11 Parts Replacements pg 11 net weight of fan 26 84 lb 12 2 kg READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE E192641 Federal regulations require ceiling fans with light kits manufactured or imported after January 1 2009 to limit total wat...

Page 2: ...your house wire is larger than 12 gauge or there is more than one house wire to connect to the corresponding fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for reference only Light kits that are not packed with the fan must be CUL Canada or UL USA listed and marked suitable for use with the model fan you are installing Switches must be CU...

Page 3: ...ll control 2 pieces q plate 1 piece r remote control cover 1 piece s faceplate 3 pieces t hardware packs page 2 Carefully open the packaging Remove items from Styrofoam inserts Remove motor housing and place on carpet or Styrofoam to avoid damage to finish Do not discard fan carton or Styrofoam inserts should this fan need to be returned for repairs Check against parts inventory that all parts hav...

Page 4: ...utlet box screws flat washers Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WARNING Failure to disconnect power supply prior to installation may result in serious injury Remove existing fixture WARNING When using an existing outlet box be sure the outlet box is securely attached to the building structure and can sup...

Page 5: ...usly removed Tighten yoke set screws and nuts securely Refer to diagram 2 Slide yoke cover and canopy over downrod Refer to diagram 3 Thread safety cable and wires through hanging ball then slide hanging ball over downrod the top of the downrod should be noted as having a set screw hole use this hole when setting the set screw Insert stop pin into top of downrod and raise hanging ball Be sure stop...

Page 6: ...l slot until it lines up with the hanging bracket tab WARNING Failure to align slot in hanging ball with tab in hanging bracket may result in serious injury or death Tip Seek the help of another person to hold the stepladder in place and to help lift the fan up to you once you are set on the ladder Find a secure attachment point wood ceiling joist highly recommended and secure safety cable It will...

Page 7: ...onnector separately with electrical tape as an extra safety measure Gently push wires and taped wire connectors into outlet box Install one 12 volt battery included in wall control IMPORTANT Wall control will not function unless battery is installed Since this fan comes with incandescent bulbs the dimmer switch labeled DIM and ON has been pre set to the ON position DIM If you do not wish to have d...

Page 8: ... can be set on each blade screw prior to installing blades Locate 15 blade attachment screws and washers in hardware pack Slide blade through one of the narrow rectangular openings on motor housing aligning holes in blade with holes in blade arm located on the underside of the motor housing refer to drawing at right Insert 3 blade attachment screws along with washers with fingers first and then ti...

Page 9: ...emoved and securely tighten all 3 screws with a Phillips screwdriver Refer to diagram 2 IMPORTANT Be careful when attaching threaded rod assembly that the wiring does not get pinched or caught under the metal edges Allow wires to come through corresponding openings in plate on threaded rod assembly Install 2 candelabra base 60 watt max bulbs included Important When replacing bulb s please allow bu...

Page 10: ... have dimming capability please move the switch to the OFF position ON OFF Refer to diagram 2 Attach black faceplate to front of wall control press down firmly Refer to diagram 3 Align holes in wall control with posts located on inside of TOP part of remote control cover and press together firmly Place wall control into BOTTOM part of remote control cover aligning posts in top of remote control co...

Page 11: ...ion ON OFF slider switch turns wall control ON or OFF switch not functional on handheld remote HIGH button turns fan to HIGH speed MED button turns fan to MEDIUM speed LOW button turns fan to LOW speed OFF button turns fan OFF L1 button not applicable for this fan L2 button turns light kit ON OFF when pressed once dims light kit when pressed and held down REV button used to REVERSE blade direction...

Page 12: ...ly 2 Check that wires in canopy are wired properly 3 Replace defective bulb with same type of bulb 4 Verify that molex connections in light kit fitter are connected properly Problem Fan and light fail to operate with wall control optional and or handheld remote control Solutions 1 Check battery power in handheld remote control 2 Learning process between fan handheld remote control and if applicabl...

Reviews: