Major Component Description
AC DISTRIBUTION BOX
BevMax 6 5800-6/3800-6
110 VAC units
Main Power Switch / Plug
Interrupts hot side of incoming power to all components in machine.
15 Amp Outlet (110 VAC)
Provides power to
Refrigeration
unit.
Transformer (T1)
Provides 24 Volt power to the Controller Board.
BevMax 6 DN5800-E6/3800-E6
220 VAC units
Main Power Switch / Plug
Interrupts hot side of incoming power to all components in machine.
Receptacle, Panel Mount
Provides power to
IEC 320 (220 VAC)
Refrigeration unit.
Transformer (T1)
Provides 24 Volt power to the Controller Board.
Service Door Switches
2 Switches - Left Switch
(10 Amp) – in XY Motor Circuits, Port Door Motor Circuit, and Picker Motor Circuit
(Power Interrupt Switch).
2 Switches - Right Switch
(10 Amp) – in Controller and Electronic Lock Circuit (Electronics Switch).
General Maintenance
The most important facets of proper care and maintenance of your machine are the electrical power supplied to it,
leveling, and cleanliness of the machine.
POWER
Refer to the cabinet serial number plate to determine the correct voltage and frequency for the machine. In the
US and Canada this is 120Vac, 60Hz, 1P. In Europe, Australia, and other export countries, this is
220/230/240Vac, 50Hz, 1P depending upon your country voltage. The serial plate also specifies the ampere
rating of the machine. This machine must be plugged into a properly rated receptacle with its own circuit
protection (fuse or circuit breaker).
CAUTION:
REMOVE POWER TO THE AC DISTRIBUTION BOX BEFORE CLEANING OR WHEN ANY ELECTRICAL
COMPONENTS ARE CONNECTED / DISCONNECTED FOR TESTING OR REPLACEMENT.
Periodically inspect the power supply cord for damage. If the cord or plug is worn or
damaged, it must be replaced with a power supply cord of the same type, size and
specification as originally provided with the machine. DO NOT USE THE VENDING
MACHINE UNTIL THE WORN OR DAMAGED CORD IS REPLACED.
In Domestic Vending Machines the Ground Fault Circuit Interrupter (GFCI) must be tested frequently and before
each use in accordance with the instructions provided on the GFCI device.
IF THE GFCI DOES NOT PASS THE
TEST, DO NOT USE THE MACHINE.
Unplug the supply cord from the receptacle and call the Crane
Merchandising Systems Technical Support Group for assistance at 1-803-266-5001.
CAUTION:
REMOVE POWER TO THE AC DISTRIBUTION BOX BEFORE CLEANING OR WHEN ANY ELECTRICAL
COMPONENTS ARE CONNECTED / DISCONNECTED FOR TESTING OR REPLACEMENT.