REFRIGERATION CONDENSER
Clean the condenser periodically of dirt or lint build-up. Remove the build up with a brush or vacuum, or blow
the dirt out of the condenser with compressed air and approved safety nozzle. Ensure nothing obstructs air
intake at the bottom of the main door. Ensure nothing obstructs air exhaust at the rear of the cabinet.
COIN ACCEPTOR
Follow the Coin Acceptor Manufacturer’s instructions.
LUBRICATING THE VENDER
The vender refrigeration system does not require any field lubrication. The hermetic refrigeration system and
fan motors are manufactured with lifetime lubrication.
NEW ATLAS CONTROL BOARD INSTALLATION
Setting Model Number - On power up the display will show “Reset Model? Continue? Yes / No”. Press the
icon and display will show “No Model Set Save? ^ (scroll up) Yes / No”. Press up or down arrow icon to scroll
through available model numbers DN5800-6, DN3800-6, DN5800-E6 (export), DN3800-E6 (export). With
vender model displayed that you are installing board press the Done icon to save.