Page
24
of
128
Error
Description
Probable
Cause
Possible
Solutions
Low Change.
The coin mechanism has reported a low or
Add coins to the tubes using the coins in/out screen in
empty condition in one or more of the coin
the monetary section of the service modes.
pay out tubes.
Do vends with coins to add coins to the tubes.
Replace coin mechanism.
No IO Comm.
The control board is not communicating with
Check for proper connections on the I/O board.
the I/O board.
Check for proper connections on the control board.
Check for damage to the harnessing.
Remove the monetary devices from the system and
check for restored communication.
Replace the I/O board.
Reset and/or replace the control board.
Please Wait.
The board is asking you to wait while it completes
Wait for the board to finish the operation.
an ongoing operation.
Re-start the machine and let it re-boot.
Remove monetary devices and re-start the machine.
Reset and/or replace the control board.
No Selections Available.
The control board is not sensing any motors
Check for motors to be homed.
available for use.
Check for motors and harnesses to be connected.
Check for power to I/O board.
Replace I/O board.
Reset and/or replace control board.
All Selections Disabled.
The control board has disabled all the motors in
Check SureVend settings and operation.
the machine.
Check motors to be homed and connected properly.
Check for a timed event to be enabled causing the
Condition.
Check/replace I/O board.
Reset/replace control board.
IO Board Voltage.
The control board has detected improper voltage
Check voltage to the machine.
for I/O board operation.
Check voltage to the I/O board.
Replace the I/O board.
Init Failed.
The control board has failed to initialize successfully.
Power down and re-start the machine.
Power down, disconnect monetary devices and
re-start the machine.
Replace the control board.