Error
Description
Probable
Cause
Possible
Solutions
Health Check Error.
The control board is reporting that an error occurred
Check temperature sensors for proper function.
in the process of conducting a health check.
Check the refrigeration system for function.
Reset machine for another cool down period to check
for proper health control function.
Reset the control board to default settings and set up
for another test.
Replace the control board and re-test.
Heath Timer Error.
The control board is reporting that an error has
Reset machine for another cool down period to check.
occurred in the operation of the timer during a
for proper health control function.
health check function.
Reset the control board to default settings and set up
for another test
Replace the control board and re-test.
Health Recheck Error.
The control board is reporting that an error
Check temperature sensors for proper function.
occurred in the process of conducting a second
Check the refrigeration system for function.
attempt at a health check.
Reset machine for another cool down period to check
for proper health control function.
Reset the control board to default settings and set up
for another test.
Replace the control board and re-test.
Capacity Sensor Failure.
An error has been reported with a sensor inside
Re-start the bill validator and check function.
the bill validator.
Replace the bill validator.
Not Calibrated Sensor Error.
An error has been reported with a sensor inside the
Re-start the bill validator and check function.
Bill
validator.
Replace
the
bill
validator.
X Motor Home Failure
The X motor home switch is not detected.
Check XY Assy is all the way to the left at the top.
Replace the X Home Switch.
Replace
the
Atlas
Board.
Y Motor Home Failure
The Y motor home switch is not detected.
Check XY Assy is all the way to the left and Delivery
Cup is all the way to the bottom.
Replace the Y Home Switch.
Replace
the
Y
Board.
Replace the Atlas Board.