MODEL
NO
HP
VOLT
PH/Hz
RPM
(Nom)
NEMA
START
CODE
INSUL.
CLASS
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
CORD
SIZE
CODE
TYPE
CORD
O.D.
± .02 (.5)
in (mm)
WINDING
RESISTANCE
MAIN -- START
2SEV1522L
1.5
240
1 / 60
3450
A
F
13.5
31.5
12/3
SOW
0.61 (15.5)
2.15 -- 12.49
2SEV1592L
1.5
200/240
3 / 60
3450
C
F
10.8/9.8
27.0
14/4
SOW
0.60 (15.2)
4.22
2SEV1542L
1.5
480
3 / 60
3450
F
F
4.9
13.5
14/4
SOW
0.60 (15.2)
17.0
2SEV1552L
1.5
600
3 / 60
3450
F
B
3.9
11.0
14/4
SOW
0.60 (15.2)
22.2
2SEV2022L
2.0
240
1 / 60
3450
C
F
16.0
42.0
12/3
SOW
0.61 (15.5)
1.26 -- 55.34
2SEV2092L
2.0
200/240
3 / 60
3450
J
F
13.2/12
30.0
14/4
SOW
0.60 (15.2)
3.08
2SEV2042L
2.0
480
3 / 60
3450
J
F
6.0
15.0
14/4
SOW
0.60 (15.2)
12.30
2SEV2052L
2.0
600
3 / 60
3450
J
B
4.8
12.0
14/4
SOW
0.60 (15.2)
19.70
2SEV1522DS
1.5
240
1 / 60
3450
A
F
13.5
31.5
12/3
SOW
0.61 (15.5)
2.15 -- 12.49
2SEV1592DS
1.5
200/240
3 / 60
3450
C
F
10.8/9.8
27.0
14/4
SOW
0.60 (15.2)
4.22
2SEV1542DS
1.5
480
3 / 60
3450
F
F
4.9
13.5
14/4
SOW
0.60 (15.2)
17.0
2SEV1552DS
1.5
600
3 / 60
3450
F
B
3.9
11.0
14/4
SOW
0.60 (15.2)
22.2
2SEV2022DS
2.0
240
1 / 60
3450
C
F
16.0
42.0
12/3
SOW
0.61 (15.5)
1.26 -- 55.34
2SEV2092DS
2.0
200/240
3 / 60
3450
J
F
13.2/12
30.0
14/4
SOW
0.60 (15.2)
3.08
2SEV2042DS
2.0
480
3 / 60
3450
J
F
6.0
15.0
14/4
SOW
0.60 (15.2)
12.30
2SEV2052DS
2.0
600
3 / 60
3450
J
B
4.8
12.0
14/4
SOW
0.60 (15.2)
19.70
3SEV1522L
1.5
240
1 / 60
3450
A
B
13.5
31.5
12/3
SOW
0.61 (15.5)
2.15 -- 12.49
3SEV1592L
1.5
200/240
3 / 60
3450
C
B
10.8/9.8
27.0
14/4
SOW
0.60 (15.2)
4.22
3SEV1542L
1.5
480
3 / 60
3450
F
B
4.9
13.5
14/4
SOW
0.60 (15.2)
17.0
3SEV1552L
1.5
600
3 / 60
3450
F
B
3.9
11.0
14/4
SOW
0.60 (15.2)
22.2
3SEV2022L
2.0
240
1 / 60
3450
C
B
16.0
42.0
12/3
SOW
0.61 (15.5)
1.26 -- 55.34
3SEV2092L
2.0
200/240
3 / 60
3450
J
B
13.2/12
30.0
14/4
SOW
0.60 (15.2)
3.08
3SEV2042L
2.0
480
3 / 60
3450
J
B
6.0
15.0
14/4
SOW
0.60 (15.2)
12.30
3SEV2052L
2.0
600
3 / 60
3450
J
B
4.8
12.0
14/4
SOW
0.60 (15.2)
19.70
3SEV1522DS
1.5
240
1 / 60
3450
A
B
13.5
31.5
12/3
SOW
0.61 (15.5)
2.15 -- 12.49
3SEV1592DS
1.5
200/240
3 / 60
3450
C
B
10.8/9.8
27.0
14/4
SOW
0.60 (15.2)
4.22
3SEV1542DS
1.5
480
3 / 60
3450
F
B
4.9
13.5
14/4
SOW
0.60 (15.2)
17.0
3SEV1552DS
1.5
600
3 / 60
3450
F
B
3.9
11.0
14/4
SOW
0.60 (15.2)
22.2
3SEV2022DS
2.0
240
1 / 60
3450
C
B
16.0
42.0
12/3
SOW
0.61 (15.5)
1.26 -- 55.34
3SEV2092DS
2.0
200/240
3 / 60
3450
J
B
13.2/12
30.0
14/4
SOW
0.60 (15.2)
3.08
3SEV2042DS
2.0
480
3 / 60
3450
J
B
6.0
15.0
14/4
SOW
0.60 (15.2)
12.30
3SEV2052DS
2.0
600
3 / 60
3450
J
B
4.8
12.0
14/4
SOW
0.60 (15.2)
19.70
Winding Resistance ± 5%, measured from terminal block. Pump rated for operation at ± 10% voltage at motor.
Optional
- Moisture sensor cord for DS models is 18/5 SOW, 0.47 ± .02 O.D.
Optional
- Temperature sensor cord for 3 phase models is 14/3 SOW, 0.53 ± .02 O.D.
Optional
- Moisture & Temperature sensor cord for 3 phase DS models is 18/5 SOW, 0.47 ± .02 O.D.
D-3.3) Pump-Down Test:
After the pump has been properly wired and lowered into the
basin, sump or lift station, it is advisable to check the system by
fi lling with liquid and allowing the pump to operate through its
pumping cycle. The time needed to empty the system, or pump-
down time along with the volume of water, should be recorded
on the start-up report.
Summary of Contents for 104189
Page 5: ...5 inches mm 2SEV DS Series 3SEV L Series 3SEV DS Series ...
Page 14: ...14 FIGURE 14 CONTIUED ...
Page 17: ...17 FIGURE 15 2SEV L 3SEV L Series Single Seal ...
Page 18: ...18 FIGURE 16 2SEV L 3SEV L Series Single Seal ...
Page 19: ...19 FIGURE 17 2SEV DS 3SEV DS Series Double Seal ...
Page 20: ...20 FIGURE 18 2SEV DS 3SEV DS Series Double Seal ...