ELECTRICAL SERVICE
*
Power Outlet Requirements
- 120 volts; not less than 110 volts at peak usage time
- 60 Hz
- Single phase
- 3 amp
- 3-pin, grounded type outlet
NOTE
THE WARRANTY ON THIS MERCHANDISER
IS NULL AND
REQUIREMENTS
VOID WHEN THE ELECTRICAL
LISTED ABOVE ARE NOT MET.
* Voltage Check
- When placed across the
HOT and
NEUTRAL
terminals,
a volt-ohmmeter should
indicate 110-130 volts ac.
* Polarity Check
* Noise
When placed across the
HOT and
GROUND
terminals,
a volt-ohmmeter should
indicate 110-130 volts ac.
Potential Check
When placed across the
NEUTRAL
and GROUND terminals,
a volt-ohmmeter should
indicate o volts ac. A reading
of greater than 1.5-2.0 volts ac
could result in noise problems
for the electronic circuitry.