11
MODEL
NO
HP
V
O
LT
PH
Hz
RPM (Nom)
NEMA ST
AR
T
CODE
FULL LOA
D
AMPS
SER
VICE
FA
CT
OR
SER
VICE
FA
CT
OR
AMPS
LOCKED R
O
T
OR
AMPS
CORD P/N
▲
CORD SIZE
CORD O.
D
.
WINDING
RESIST
ANCE
MAIN - ST
AR
T
XSHVT Pump
6XSHVT20098*
20.0
208
3
60
870
J
69.0
1.2
76.0
400.0
138318
6/4 - 18/4
1.14 ± .03
.121
230
75.1
79.0
6XSHVT20048*
20.0
460
3
60
870
J
37.6
1.2
41.1
200.0
138317
8/4 - 18/4
1.12 ± .02
.483
6XSHVT20058*
20.0
575
3
60
870
J
30.1
1.2
32.9
160.0
138317
8/4 - 18/4
1.12 ± .02
.77
6XSHVT25098*
25.0
208
3
60
870
H
82.3
1.2
98.8
400.0
138319
2/4 - 18/4
1.47 ± .03
.121
230
84.0
94.5
6XSHVT25048*
25.0
460
3
60
870
H
42.0
1.2
47.2
200.0
138317
8/4 - 18/4
1.12 ± .02
.483
6XSHVT25058*
25.0
575
3
60
870
H
33.6
1.2
37.8
160.0
138317
8/4 - 18/4
1.12 ± .02
.77
6XSHVT30098*
30.0
208
3
60
870
F
98.8
1.2
124.1
400.0
138319
2/4 - 18/4
1.47 ± .03
.121
230
94.5
108.6
6XSHVT30048*
30.0
460
3
60
870
F
47.2
1.2
54.3
200.0
138317
8/4 - 18/4
1.12 ± .02
.483
6XSHVT30058*
30.0
575
3
60
870
F
37.8
1.2
43.5
160.0
138317
8/4 - 18/4
1.12 ± .02
.77
6XSHMN20064
20.0
208
3
60
1750
G
63.0
1.2
74.6
323.0
138318
6/4 - 18/4
1.47 ± .03
.098
6XSHMN25094
25.0
208
3
60
1750
G
77.8
1.2
93.4
359.0
138319
2/4 - 18/4
1.47 ± .03
.098
230
1750
71.4
82.3
.098
XSHMH Pump
6XSHMH30094
30.0
208
3
60
1750
E
93.4
1.2
116.9
359.0
138319
2/4 - 18/4
1.47 ± .03
.098
230
82.3
98.7
.098
6XSHMH40034
40.0
230
3
60
1750
E
106.0
1.2
126.4
486.0
138319
2/4 - 18/4
1.47 ± .03
.063
6XSHMH40044
40.0
460
3
60
1750
E
53.0
1.2
63.2
243.0
138318
6/4 - 18/4
1.14 ± .03
.248
6XSHMH40054
40.0
575
3
60
1750
E
42.4
50.6
194.4
138317
8/4 - 18/4
1.12 ± .02
.382
6XSHMH50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
6XSHMH50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
XSHMJ Pump
6XSHMJ50044
50.0
460
3
60
1750
F
67.1
1.2
79.0
339.0
138318
6/4 - 18/4
1.14 ± .03
.15
6XSHMJ50054
50.0
575
3
60
1750
F
53.7
1.2
63.2
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
6XSHMJ60044
60.0
460
3
60
1750
E
79.0
1.2
95.5
339.0
138319
2/4 - 18/4
1.47 ± .03
.15
6XSHMJ60054
60.0
575
3
60
1750
E
63.2
1.2
76.4
271.2
138318
6/4 - 18/4
1.14 ± .03
.245
6XSHMJ20096
20.0
208
3
60
1150
H
60.3
1.2
71.5
354.0
138318
6/4 - 18/4
1.14 ± .03
.111
7
230
57.2
69.8
6XSHMJ25096
25.0
208
3
60
1150
G
75.2
1.2
90.8
354.0
138319
2/4 - 18/4
1.47 ± .03
.111
7
230
70.8
82.6
6XSHMJ25046
25.0
460
3
60
1150
G
35.4
1.2
41.3
177.0
138317
8/4 - 18/4
1.12 ± .02
.4397
6XSHMJ25056
25.0
575
3
60
1150
G
28.3
1.2
33.0
141.6
138317
8/4 - 18/4
1.12 ± .02
.6857
Moisture and
Temperature sensor leads are integral to power cord.
Winding Resistance ± 7.5%
Winding resistance measured in OHMS @ 25°C (Between Lines) at motor leads.
Pump rated for operation at ± 10% voltage at motor
.
▲ Cord Suffix: XF - 50 Feet, XJ - 75 Feet, or XL
- 100 Feet
▲ Cord sold separately (After March-2016 ONL
Y). Pumps built Before March-2016 refer to Cord
Assembly Kit, see page 28.
* Select impeller diameter when ordering.
CHART ‘E’
Summary of Contents for BARNES 10XSHD
Page 48: ...Notes ...