SECTION: A- PUMP SPECIFICATIONS - SPRINT III

DISCHARGE: ‡

 2" (51mm) NPT or Compression, 

& 3" (76mm) Compression, Vertical

LIQUID TEMPERATURE:

  104°F (40°C) Continuous.

VOLUTE:

 

Cast Iron ASTM A-48, Class 30.

MOTOR HOUSING:

Cast Iron ASTM A-48, Class 30.

END BELL:

 

Cast Iron ASTM A-48, Class 30.

IMPELLER:

 

Design: 

6 Vane, Open, Dynamically
Balanced, ISO G6.3.

Material: 

Ductile Iron

SHAFT:

 416 

Stainless 

Steel

SQUARE RINGS:

Buna-N

HARDWARE:

 

300 Series Stainless Steel

PAINT:

 Air 

Dry 

Enamel.

SEAL:

 

Design: 

Single Mechanical, Oil-Filled Reservoir.

Material: 

Rotating Face - Carbon
Stationary Face - Ceramic
Elastomer - Buna-N
Hardware - 300 Series Stainless

CABLE ENTRY:

10 ft.(3M) Cord, (Plug on Single Phase).
Pressure Grommet For Sealing
And Strain Relief. Sealed Junction
Chamber with Terminal Block.

SPEED:

 

1750 RPM (Nominal).

UPPER BEARING:

 

Design: 

Sleeve

Lubrication:

 Oil

Load:

 Radial

LOWER BEARING:

 

Design:

 

Single Row, Ball

Lubrication:

 Oil 

Load:

 

Radial & Thrust

MOTOR: 

Design:

 

NEMA L-Single Phase,
NEMA B-Three Phase Torque Curve. 
Completely Oil-Filled, Squirrel Cage 
Induction.

Insulation:

 Class 

SINGLE PHASE:

.5HP Split -Phase with Current Relay.
Includes Overload Protection In Motor.

THREE PHASE: 

Dual Voltage 230/460;
Requires Overload Protection to be
Included in Control Panel.

FLOAT:

Automatic Models. 15ft. Cable, Wide 
Angle, Polypropylene. Attached to 
Pump, or to Discharge Piping. ON and
OFF Points Are Adjustable.

OPTIONAL EQUIPMENT:

 Additional Cable.

‡ Specify Flange Size and type when ordering. 
2" Discharge handels 1-7/8" soilds, 3" Discharge handles 2" solids.

IMPORTANT !

1.) PUMP MAY BE OPERATED 

"DRY"

 FOR EXTENDED PERIODS WITHOUT DAMAGE TO MOTOR AND/OR SEALS. 

2.) THIS PUMP

 IS

 APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION II HAZARDOUS LOCATIONS.

3.) THIS PUMP IS 

NOT

 APPROPRIATE FOR THOSE APPLICATIONS SPECIFIED AS CLASS I DIVISION I HAZARDOUS LOCATIONS.

4.) INSTALLATIONS SUCH AS DECORATIVE FOUNTAINS OR WATER FEATURES PROVIDED FOR VISUAL ENJOYMENT MUST BE INSTALLED IN

ACCORDANCE WITH THE NATIONAL ELECTRIC CODE ANSI/NFPA 70 AND/OR THE AUTHORITY HAVING JURISDICTION. THIS PUMP IS NOT

INTENDED FOR USE IN SWIMMING POOLS, RECREATIONAL WATER PARKS, OR INSTALLATIONS IN WHICH HUMAN CONTACT WITH PUMPED 
MEDIA IS A COMMON OCCURRENCE.

2.00" 

(51)

 NPTor,

2" 

(51)

 Compression or,

3" 

(76)

 Compression

Disch.

For Sch. 40 Pipe.

5.75

(146)

5.06 

(129)

11.31 

(287)

8.20

(208)

3.44

(87)

3.44

(87)

18.62

(473)

2.00" 

(51)

 NPTor,

2" 

(51)

 Compression or,

3" 

(76) 

Compression

Disch.

For Sch. 40 Pipe.

*9.00

(229)

120°

Pumping

* Factory Set, Adjustable.

5.75

(146)

11.31 

(287)

8.20

(208)

3.44

(87)

3.44

(87)

18.62

(473)

5.06 

(129)

6

Summary of Contents for Barnes SPRINT II Series

Page 1: ...pump As a result of Crane Pumps Systems Inc constant product improvement program product changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 0603 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com P...

Page 2: ...SPRINT II SERIES EXPLODED VIEW Fig 16 22 SPRINT II SERIES PARTS LIST 23 24 SPRINT III SERIES CROSS SECTION Fig 17 25 SPRINT III SERIES EXPLODED VIEW Fig 18 26 SPRINT III SERIES PARTS LIST 27 WARRANTY INFORMATION 29 WARRANTY START UP REPORT WARRANTY REGISTRATION SPECIAL TOOLS AND EQUIPMENT INSULATION TESTER MEGGER DIELECTRIC TESTER SEAL TOOL KIT see parts list PRESSURE GAUGE KIT see parts list Othe...

Page 3: ...re on any pump and on end suction and self priming pump the heat build may cause the generation of steam with resulting dangerous pressures It is recommended that a high case temperature switch or pressure relief valve be installed on the pump body ELECTRICAL 21 To reduce risk of electrical shock pump must be properly grounded in accordance with the National Electric Code NEC or Canadian Electrica...

Page 4: ... Overload Protection In Motor THREE PHASE Dual Voltage 230 460 Requires Overload Protection to be Included in Control Panel FLOAT Automatic Models 15ft Cable Wide Angle Mercury Polypropylene Attached to Pump or to Discharge Piping ON OFF Points Are Adjustable OPTIONAL EQUIPMENT Additional Cable Specify Flange Size and type when ordering IMPORTANT 1 PUMP MAY BE OPERATED DRY FOR EXTENDED PERIODS WIT...

Page 5: ...e with Current Relay Includes Overload Protection In Motor THREE PHASE Dual Voltage 230 460 Requires Overload Protection to be Included in Control Panel FLOAT Automatic Models 15ft Cable with Plug High Temperature Mechanical Polypropylene Attached To Pump or To Discharge Piping OPTIONAL EQUIPMENT Additional Cable Specify Flange Size and type when ordering inches mm IMPORTANT 1 PUMP MAY BE OPERATED...

Page 6: ...30 460 Requires Overload Protection to be Included in Control Panel FLOAT Automatic Models 15ft Cable Wide Angle Polypropylene Attached to Pump or to Discharge Piping ON and OFF Points Are Adjustable OPTIONAL EQUIPMENT Additional Cable Specify Flange Size and type when ordering 2 Discharge handels 1 7 8 soilds 3 Discharge handles 2 solids IMPORTANT 1 PUMP MAY BE OPERATED DRY FOR EXTENDED PERIODS W...

Page 7: ...d Protection In Motor THREE PHASE Dual Voltage 230 460 Requires Overload Protection to be Included in Control Panel FLOAT Automatic Models 15ft Cable Wide Angle Polypropylene Attached to Pump or to Discharge Piping ON and OFF Points Are Adjustable OPTIONAL EQUIPMENT Additional Cable Specify Flange Size and type when ordering 2 Discharge handels 1 7 8 soilds 3 Discharge handles 2 solids inches mm I...

Page 8: ... under water for more than one 1 month 2 Immediately upon satisfactory completion of the test the pump is removed thoroughly dried repacked in the original shipping container and placed in a temperature controlled storage area B 4 Service Centers For the location of the nearest Barnes Pumps Service Center check your Barnes Engineered catalog your Barnes Pumps Inc representative or Barnes Pumps Inc...

Page 9: ...nd 5 5 inches on SPRINT III Series above the pump bottom 6 Figure 3 shows a typical connection for pumps with the wide angle float and piggy back plug for manual and automatic operations Automatic Plug float cord into outlet then plug pump cord into float cord Manual Plug pump cord directly into outlet The receptacle must be a three pin polarized type with an internal ground If existing receptacle...

Page 10: ...PERATION D 1 Check Voltage and Phase Before operating pump check to make sure that the voltage and phase information stamped on the pump s identification plate matches the available power D 2 Check Pump Rotation Before putting pump into service for the first time the motor rotation must be checked Improper motor rotation can result in poor pump performance and can damage the motor and or pump 1 To...

Page 11: ...T II 1052L 1 0 575 3 M 1 8 10 0 16 4 SO 0 425 38 8 34 5 Mercury Switch on 115 volt and Mechanical on 230 volt SPRINT IIA Cable 16 2 SJOW A 0 320 O D Piggy Back MODEL NO HP VOLT PH NEMA START CODE FULL LOAD AMPS LOCKED ROTOR AMPS CORD SIZE CORD TYPE CORD O D WINDING RESISTANCE PER PHASE WINDING RESISTANCE MAIN START BL Y Y R AUTOMATIC SPRINT IIA 512HT 0 5 115 1 M 12 0 46 0 16 3 STOO 0 390 1 15 1 04...

Page 12: ...pleted as applicable Return one copy to Barnes Pumps and store the second in the control panel or with the pump manual if no control panel is used It is important to record this data at initial start up since it will be useful to compare to when servicing the pump in the future Insulation Test Before the pump is put into service an insulation megger test should be performed on it The ohm values as...

Page 13: ...Fig 4 CONNECTION DIAGRAMS USED FOR DETERMINING WINDING RESISTANCE 13 ...

Page 14: ...for contamination using an oil tester with a range to 30 kilovolts breakdown 3 If oil is found to be clean and uncontaminated measures above 15 KV breakdown refill the motor housing as per section F 1 3 4 If oil is found to be dirty or contaminated or measures below 15KV breakdown then the pump must be carefully inspected for leaks at the shaft seal 30 cord inlet 5 o rings 9 28 and pipe plug 11 be...

Page 15: ... 2 and install in pump cover 1 F 2 Assembly F 2 1Retaining Ring Install retaining ring 25 on shaft using care so shaft seal mounting surfaces are not nicked or scratched F 2 2 Seal Seat Place drive end bell 29 with seal side up on end bell locating tool Fig 6 on arbor press Apply small amount of light oil to outside of Buna N part of seal seat Set squarely over seal seat recess in end bell with ce...

Page 16: ...D 4 assemble motor to end bell 29 with 4 motor bolts Place Tetraseal 28 in groove in end bell 29 and lower shell 13 over motor while feeding leads out terminal block opening and bolt to end bell with screws 12 Place o ring 16 over motor leads and make connectiond as shown in Figs 10 thru 14 Secure terminal block 15 with 4 round head screws 14 Conduct motor air check per Section F 1 4 and fill with...

Page 17: ...Fig 10 SINGLE PHASE 5HP 115 208 OR 230 VOLT 1750 OR 3450 RPM Fig 11 SINGLE PHASE 1HP 208 OR 230 VOLT 3450 RPM Fig 12 THREE PHASE 1HP 208 OR 575V 3450 RPM 5HP 208 OR 575V 1750 OR 3450 RPM 17 ...

Page 18: ...Fig 13 THREE PHASE 1HP 230V 3450 RPM 5HP 230V 1750 OR 3450 RPM Fig 14 THREE PHASE 1HP 460V 3450 RPM 5HP 460V 1750 OR 3450 RPM 18 ...

Page 19: ...ign configuration This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific to e...

Page 20: ...Clean impeller cavity and inlet of any obstruction 9 Loosen union slightly to allow trappedair to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump...

Page 21: ...Fig 15 SERIES SPRINT II 21 ...

Page 22: ...Fig 16 SERIES SPRINT II 22 ...

Page 23: ... 00120 18 1 Impeller 5HP 016 00001 802 1HP 016 00001 801 19 1 Volute 016 00003 101 20 1 Capacitor 1HP 208V 220V 53MFD 625 02744 Capacitor 1HP 230V 220V 40MFD 625 02653 21 1 O Ring 625 01557 22 1 Current Relay 5HP 115V 1Ph 625 02643 001 5HP 208 230V 1Ph 625 02651 001 Voltage Relay 1HP 208 230V 1Ph 625 02652 23 2 Jumper Wire N016 00127 001 24 2 Capacitor Mount Clip 016 00008 25 2 Retaining Ring 625 ...

Page 24: ...90110 100 40A Discharge Flange 2 016 90110 100 40B 1 Flange Gasket 2 625 02637 41 1 Flange Assy 3 Compression N016 90109 100 41A 1 Discharge Flange 3 016 90109 100 41B 1 Flange Gasket 3 625 02638 42 1 Flange Assy 1 50 NPT N016 00111 101 42A 1 Discharge Flange 1 50 NPT 016 00111 101 42B 1 O Ring 625 01551 43 1 Flange Assy 2 00 NPT N016 00106 101 43A 1 Discharge Flange 1 50 NPT 016 00106 101 43B 1 O...

Page 25: ...SERIES SPRINT III Fig 17 25 ...

Page 26: ...SERIES SPRINT III Fig 18 26 ...

Page 27: ...x 016 00050 101 19 1 Volute Vortex 016 00051 101 22 1 Current Relay 115V 1Ph 625 02641 001 208V 1Ph 625 02651 001 230V 1Ph 625 02650 001 23 2 Jumper Wire N016 00127 001 25 2 Retaining Ring 625 02579 26 1 Ball Bearing 625 02639 27 4 Fil Hd Screw 8 32 x 875 Lg Stainless 10 97 1 28 1 Tetraseal 625 00042 29 1 End Bell 016 00052 101 30 1 Shaft Seal TP CE B 625 02635 001 31 1 Motor 5HP 115V 1Ph N016 026...

Page 28: ...NOTES 28 ...

Page 29: ...of the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable ...

Page 30: ...ield performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control Components or accessories suppl...

Page 31: ...bottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Motor measured at pump control Red Black Ohms Red White Ohms White Black Ohms Resistance Of Ground Circuit Between Control Panel and Outside of Pump Ohms MEG Ohms Check of Insulation Red to Ground White...

Page 32: ...n Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks Does check valves operate properly Flow Does station appear to operate at proper rate Pump down time Noise Level High Medium Low Comments Equipment Difficulties during start up MANUALS Has operator ...

Page 33: ...ERIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Page 34: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE ...

Reviews: