13
BevMax 4 5800-4/3800-4 Board Programming
Service Mode
Test
Mode Setup
Mode
1 Setup
Mode
2
A Step
through
below
A Step
through
below
A Step
through
below
A Step
through
below
B Cash
Box
B List
Errors
B Enter
Message
B STS
Enabled/Disabled
C Sales
C Light
Timer
C Clear
Message
C Custom
STS
D Display
Temperature
D Enable
Snack
Menus D Enable/Disable
$
D Default
STS
E Set Refrig. Temp.
E Keypad
Test
E Set Happy Hour Time
E Display
STS
F Clear
Totals
F
*Factory Diagnostics
F Master
Reset
F
Set No Vend Limit
1 Number
Sold
1
Tube Fill/Dispense
1 Machine
Number
1 Multivend
2 Enable Item (Disable)
2 Daylight
Savings
2 Set
Happy
Hour
2 Select
Language
3 Sales by Column
3
Set Not Available
3
Set Not Available Time
3
Sold Out Enable
4 Escrow
4
Set Credit Timer
4 Consumer
Overpay
4 Price
Display
5 Force
Vend
5 Door
Open
5
Date/Time
5 Storage
Temp
Enable
6 Set Temp. (F or C)
6 Power
out
6 Total
Sales
6 Interval
Sales
Reset
7
Set Prices
(Regular &
Secondary
7 Test
Health
Guard
7 Health
Control
7
Set Lights Off
8 ***Set Shelf Location (G, M1,
M2, D, E, E1, D2)
8 Display
Health
Guard 8 Update
Software
8 Double
Talk
9 Relay
Toggle
Test
9
**Test Vend
9
Set Lights Off Time
9
Set Storage Time
0 Clear
Errors
0 Show
Checksum
0 Enter
New
Password
0
Set Storage Temp
*Factory Diagnostics –
sub-menus
A
Build ####
= software revision build number
B
Model # =
Set Model Number DN5800-4, DN3800-4, DN5800-E4, DN3800-E4
E
Extended Cup
= All BevMax 4 5800-4 - Enabled
F Delivery
(Picker)
Cup Sensor
Option = BevMax 4 5800-4 with cup sensor set ON, BevMax 4 5800-4 with out cup sensor set OFF.
1
Position Test
= F – goes home; 0 – cycles plunger; * - stops all motors; Shelf letter – moves cup to shelf selected; Column # - moves cup to column selected.
2
Port Test
= A – opens port; B – closes port; C – sensor test ON’; D – sensor test OFF; E – cup LED’s on; F – port LED’s on; * - All Stop.
3
Delivery
(Picker)
Cup Check
= “On (status of cup sensor):#”; “In (detects product in cup):#”; “Out (picker out switch status):#”; “Hm (picker home switch status):#”.
4
Repeat Vend
5
Vend Error Codes
= Factory Use Only / Do Not Use.
6
Product Sensors
= All BevMax 4 5800-4 set ON
7 Factory Use Only / Do Not Use
8
Shelf Offset
= BevMax 4 5800-4 Shelf Location “D2” = 700
9 (Not
Used)
0
Hook Swipe X
= sets far right travel distance to Delivery door (BevMax 4 5800-4 factory default = 93871).
**Test Vend
= Test Mode press “9” and “*” (enter) to get to “
Enter Selection
”. Close the service door and choose desired selection to test vend.
To set Timers for schools
= Set Date/Time / Set Not Available blocks / Set Not Available Times / Set Daylight Savings Time
Cash and Sales Numbers
= Sales / Number Sold / Sales by Column / Total Sales / Cash Box
***Set Shelf Location
= Service Mode press “8” - BevMax
4
5800-4 = D2 – Domestic, E3 - Export 5 Shelf, E4 – Export 4 Shelf (default is 700)
Set Hook Swipe X
= Test Mode press “F” and “*” (enter) to get to “
Factory Diagnostics”.
Press “8” and “*” (enter) to get to Hook Swipe ##### (default is 91871).
Summary of Contents for BevMax 4
Page 2: ...1 ...
Page 69: ...68 ...
Page 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Page 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Page 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Page 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Page 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Page 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Page 98: ...97 ...