37
XY not
working
Visual check. Where is picker cup located?
HOME
NOT HOME
Is vender plugged in?
NO
YES
Go to Factory
Diagnostics.
Pull the top door
switch out.
Do a test vend with
door closed. Works
NO
YES
Check Motor by
swapping X & Y
motors.
YES
NO
Plug in or replace as
needed.
Do the Encoder counts
increase & decrease
when moving the XY
manually?
YES
NO
Green light =
Y Axis Home.
Check harnesses & connections to P8,
P14, & P15 at control board are good?
YES
NO
Are P3 & J3 connected
to control board?
NO
YES
Plug in connector.
Plug in Vender.
Manually
move XY
to HOME
position.
In position test are the Red,
Yellow, & Green LED’s on
control board illuminated?
YES
NO
Yellow light =
X Axis Home.
Red light =
Plunger
Home.
Does XY move
to HOME
position using
Key Pad?
YES
NO
Change Control
Board.
Change failed
Motor.
RED light is
ON
OFF
Red Light
Plunger
Home
Visually confirm
plunger in home
position
YES
NO
Refer to
Picker Cup
TS
Check top door switch working?
NO
YES
Replace switch.
Is fuse in
control board
good?
NO YES
Replace
Check, repair,
replace harness.
Problem solved?
NO
YES
See Port Door
trouble shooting
Is P1 connected to
control board?
NO
YES
Summary of Contents for BevMax 4
Page 2: ...1 ...
Page 69: ...68 ...
Page 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Page 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Page 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Page 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Page 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Page 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Page 98: ...97 ...