44
Go to Factory Diagnostics.
Check encoder counts. Send to
home, does home switch light
come on?
YES
NO
Send cup to home
position. Does it go
home?
YES
NO
Send cup to “E2-E8”
positions. Does it stop in
correct position?
YES
NO
Is the horizontal
alignment correct?
YES
NO
See X Axis
TS
Adjust Shelf
Offset as required.
See programming
Check Harness,
Keypad, Motor,
Board.
See XY not
working page
34.
Check Harness,
Keypad, Motor,
Board.
Do a Keypad test. Works?
YES
NO
CUP AT WRONG LOCATION
LEFT /RIGHT or X AXIS
Repeat test at
several locations.
Does it stop in
correct position?
NO
YES
Close door, do a
test vend.
Change
Keypad.
Summary of Contents for BevMax 4
Page 2: ...1 ...
Page 69: ...68 ...
Page 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Page 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Page 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Page 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Page 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Page 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Page 98: ...97 ...