50
SELECTION WILL NOT VEND
Selection will not vend.
Vend price set incorrectly.
Check price and
reset if
necessary.
Insufficient credit.
Check price,
ensure credit is
equal to or
greater.
Product and gate mis-
matched.
Check gate /
spacer.
Gate sticking.
Move product away from gate (removing the weight)
and use "Test Vend" to check gate operation. Use
small amount of WD-40 on pins and recheck.
Check for bent pins.
Dirty / worn tray insert
(slide).
Clean /
check for flash /
replace.
Loose connections.
Check cable
connections at
controller board
and motors.
Defective Plunger arm.
Use "Vend Test" to
check plunger arm,
replace if necessary.
Defective cable.
Replace cable.
Defective controller
board.
Replace.