7
The electronic door lock assembly is supplied by
TriTeq Lock and Security. Crane Merchandising
Systems does not carry parts for the TriTeq Electronic
Door Lock.
For parts and assistance, please contact:
TriTeq
701 Gullo
Elk Grove Village, IL 60007
Tel: 847-640-7002
Fax: 847-640-7008
Email: triteqlock.com
MANUAL LOCK
Open the service door on the right side using the key
provided in the coin return cup, or if shipped with a
locking clip, remove the clip and install the lock.
Ensure there is no power to the AC Distribution Box.
On venders with a main power switch on the AC
Distribution Box the switch needs to be in the OFF
position. On venders with a main power quick
disconnect plug on the AC Distribution Box the quick
disconnect plug needs to be unplugged. Check that
all connectors are firmly seated on the control board
and at the various components on the service door
(coin mech, keypad, etc.).
Retrieve the main power plug from the hole in the rear
of the vender and plug the cord in a properly
grounded 120VAC, 15 Amp receptacle (U.S. and
Canada).
Open the service door and apply power to the AC
distribution Box (if equipped with a bill acceptor, the
acceptor should cycle twice). The display on the door
will briefly show the software version in use as
“Software ###.## (ie 70#.#1) followed by the default
idle message “ENJOY A REFRESHING DRINK”, the
fluorescent lamp should be lit and the cooling unit
should start. If the display shows “OUT OF
SERVICE”, or the cooling unit fails to start, refer to the
TROUBLESHOOTING SECTION beginning on page
34.
SERVICE NOTE
Battery Backup
The battery backup is used to maintain the date and
time in case of power interruptions, or any time the
main power is off. When the vender is shipped, the
battery is connected and memory is being maintained.
If the vender is to be stored for long periods of time,
disconnecting the battery is recommended. The
following steps will guide you through this procedure.
•
Open the service door, turn the main power
switch to the off position or unplug the main
power harness located on the front of the
power box.
•
Locate the control board mounted on the rear
wall.
•
Remove the battery from its holder (B1).
PLACING THE VENDER ON
LOCATION
!! CAUTION !!
DO NOT TRANSPORT THE
VENDER TO OR FROM THE
LOCATION LOADED WITH
PRODUCT OR DAMAGE TO THE
VENDER MAY RESULT.
The vender is intended for
INDOOR USE ONLY.
It
should be kept out of direct sunlight and away form
any heat source. This machine is not suitable for
installation in an area where a water jet or hose and
nozzle may be used.
The vender must be on a solid, flat and level surface.
Ensure the flooring can bear the weight load of a fully
loaded vender (approximately
1109
lbs. or 413kg).
The vender must be positioned close enough to an
electrical outlet so that an extension cord is not
required. If the machine will be subject to user misuse
or vandalism, it is recommended that the vender be
secured to the floor or wall as described in Crane
Merchandising Systems / Dixie-Narco Technical
Bulletin 344. Due to the large size and weight of the
Vender, never attempt to move the Vender with a
Hand Truck or Stair Climber. Use a pallet jack or
Vender/Cooler Dollies at all times when moving the
Vender. The vender should never be slid or pushed in
place. Never side load the leveling legs; doing so will
cause damage to the legs. Do not transport the
vender to or from customer locations loaded with
product, as damage may result due to excessive
weight. Be sure to test vender for proper operation
before putting in to service on location. Call the Crane
Merchandising Systems Technical Service
Department or your Crane Merchandising Systems
Representative for assistance.
ACCEPTABLE AMBIENT OPERATING
TEMPERATURE RANGE.
Generic and Pepsi BevMax 4 5800-4/3800-4
equipment manufactured by Crane
Merchandising Systems is designed to work
properly in a temperature range of 75°F to 90°F
(23°C to 32°C) in still air 65% R.H. non-
condensing.
LEVEL THE VENDER
Adjust the front leveling legs, ensuring that an even
gap exists between the glass door and the top
security angle and receiver box, and then level the
cabinet front to rear. A carpenter’s level will help
verify that the vender is level. Leveling legs are
adjusted using a wrench or socket 1 ½” or 38 mm in
Summary of Contents for BevMax 4
Page 2: ...1 ...
Page 69: ...68 ...
Page 70: ...69 MACHINE FRONT VIEW 6A 9 11 13 14 5B 5A 7 3A 4B 19 18 6B 3C 4B 4A 2 4C 17 16 1 12 20 ...
Page 72: ...71 CABINET DETAIL PRODUCT AREA 3 2B 12 9 6 7 2A 8 5 14 11 ...
Page 74: ...73 CABINET DETAIL SERVICE DOOR AREA 1 16 10 4 7 11 5 17 11 4 5 20 22 21 14 12 2 10 15 8 ...
Page 78: ...77 DELIVERY PICKER CUP ASSEMBLY 11 1 2 21 10 5 16 14 15 17 4 7 12 13 19 6 19 20 9 8 19 3 22 ...
Page 84: ...83 GATE TRAY DETAIL 8 3 7 11 1 2 4 6 12 13 14 10 9 ...
Page 96: ...95 HARNESSES 8 2 10 1 4 9 3 6 7 11 24 18 17 12 21 16 23 19 20 15 25 26 22 5 ...
Page 98: ...97 ...