BevMax_Media_Programming_10_6_10 Page 18 of 106 08/15/2013
Error
Description
Probable
Cause
Possible
Solutions
Bill Validator Disabled.
The control board has disabled the bill validator.
Check for coins in the payout tubes of the coin
Mechanism.
Check for a fault with the bill validator.
Check Winner Prize.
The control board has detected a failed winner vend.
Check for the presence of product.
Check motor function.
POWER OFF.
The control board has detected a power outage.
Check the power cord and plug.
Check the circuit breaker.
Check the On/Off switch in the machine.
DOOR OPEN.
The control board is reporting that the door has
Check to see if someone has been in the machine.
been
opened.
Check
the
door
switch.
Check switch connections and harnessing for damage.
Power Save mode.
The machine is in a power save event.
Let the event complete.
Modify or eliminate the event in the software settings.
Return Air Temperature
The control board has recorded sensor readings
Check the readings for high or low temperatures.
Sensor Error.
that are outside of allowed parameters.
Check for a defrost event.
Check for ice buildup on the evaporator.
Evaporator Temperature
The control board has recorded sensor readings
Check the readings for high or low temperatures.
Sensor Error.
that are outside of allowed parameters.
Check for a defrost event.
Check for ice buildup on the evaporator.
Check for evaporator fan function.
Cabinet Temperature
The control board has recorded sensor readings
Check the temperature readings against a
Sensor Error.
that are outside of allowed parameters.
thermometer, placed at near the same level as the
sensor, for accuracy.
Replace the sensor.
Condenser Temperature
The control board has recorded sensor readings
Clean screens and condenser.
Sensor Error.
that are nearing or outside of allowed parameters.
Check to see that the machine has six inches off
clearance from the wall.
Replace the sensor.
Error
Description
Probable
Cause
Possible
Solutions