Condenser High Side
Temperatures at or nearing 150 degrees are being
Clean screens and condenser.
Warning.
Reported.
Check to see that the machine has six inches off
clearance from the wall.
Replace the sensor.
Condenser High Side Error.
Temperatures of an unlikely nature are being
Check the temperature sensor and connections.
Reported (such as 999 degrees). Cooling functions
Replace the temperature sensor.
are
stopped.
Evaporator Coil Low Side
The control board has recorded sensor readings that
Check for evaporator fan function.
Warning.
are nearing or outside of allowed parameters.
Check for ice buildup on evaporator.
Check for excessive moisture.
Evaporator Coil Low Side
The control board has recorded sensor readings that
Check for evaporator fan function.
Error.
are
outside
of
allowed parameters. Cooling functions
Check for ice buildup on evaporator.
are
stopped.
Check
for
excessive
moisture.
Replace the temperature sensor.
IO Even Input Short.
The I/O board is reporting that an even input switch
Check for motor errors (out of home position)
has
shorted
out.
replace
the
I/O
board.
IO Odd Input Short.
The I/O board is reporting that an odd input switch
Check for motor errors (out of home position)
has
shorted
out.
replace
the
I/O
board.
Sold Out Machine.
The control board has determined that all selections
Check SureVend settings and function.
in the machine are sold out.
Check for vend motor function.
Check harnessing connections.
Check for board function (selection configuration).
Recycler Motor Problem.
A problem has been detected with a motor inside
Check for an obstruction or blockage within the
the
bill
validator. recycler
which
is stopping the motor from completing
its cycle.
Replace the bill validator.
Recycler Sensor Problem.
A problem has been detected in a sensor within
Replace the recycler cassette.
the
recycler.
Replace
the
bill
validator.