BevMax_Media_Programming_10_6_10 Page 87 of 106 08/1
iii. Check
rollers.
iv. Check harness and motor.
v. Replace control board.
6. Product Will Not Load From Delivery Cup Assembly To Port Assembly.
a. Perform Test Vend in Test Menu to test movement.
b. Check Model # is set to correct cabinet.
c. Check belt tension.
d. Check Service Wall Port Door Assembly is securely installed.
7. Port Assembly On Service Door Will Not Open.
a. Perform Test in Test Menu Port and Cup Sensors to test switch.
i. Port Open Switch is Off when Port Door is closed and switch is in open
position and good.
ii. Port Closed Switch is On when Port Door is closed and switch is pressed
and good.
b. Check for syrup or dirt build up, or debris.
c. Check for broken parts.
d. Replace
port
assembly.
e. Check harness and motor.
f. Replace I/O Control board.
8. Double Vend From Gate
a. Is correct gate assembly used for product being vended.
b. Too many packages loaded in column.
c. Check Plunger Return Spring.
d. Check Cup Motor Cam.
e. Check the trigger on the Plunger Assembly.
f. Check the Picker Cup Ribbon Cable for bad connection or damage.
g. Check the Y E Chain Harness for bad connection or damage.
h. Check the X/Y E Chain Harness for bad connection damage.
i. Change Y Motor Board.
j. Change Delivery (Picker) Cup Base Board.
9. Package Not Sliding On Slide Assembly.
a. Vender not level.
b. Trays not secured to Tray Supports.
c. Slide not installed correctly.
d. Slide dirty. Clean and apply Armoral or Food Grade Silicone.
10. Delivery Cup Assembly Caught On Tray
a. Check vender is level.
b. Check Shelf setting.
c. Check spring on Y belt is installed correctly.
d. Check
rollers.