background image

 

Page 6 of 19 

Repair any scratches on painted surfaces to 
prevent corrosion. 

DRAIN PAN, DRAIN TUBE, AND DRAIN HOSE 

 

To prevent mold and mildew growth, 
and to avoid personal injury or 
property damage, the drain pan, 
drain tube, and drain hose must be 
properly aligned and routed.  Ensure 
nothing obstructs the drain tube or 
drain hose and that the hose is not 
bent, pinched, or twisted in such a 
way as to prevent the flow of 
condensate.  Periodically inspect the 
drain pan, drain tube, and drain hose 
for alignment and the presence of 
dirt, debris, mold, and mildew.  Clean 
as needed. 

 

WARNING 
THE COMPRESSOR ELECTRICAL CIRCUIT IS 
ALWAYS LIVE WHEN THE PLUG IS CONNECTED 
TO AN ELECTRICAL OUTLET

REFRIGERATION CONDENSER 

Clean the condenser periodically of dirt or lint 
build-up.  Remove the build up with a brush or 
vacuum, or blow the dirt out of the condenser 
with compressed air and approved safety 
nozzle.  Ensure nothing obstructs air intake at 
the bottom of the main door.  Ensure nothing 
obstructs air exhaust at the rear of the cabinet. 

COIN ACCEPTOR 

Follow the Coin Acceptor Manufacturer’s 
instructions. 

LUBRICATING THE VENDER 

The vender refrigeration system does not 
require any field lubrication.  The hermetic 
refrigeration system and fan motors are 
manufactured with lifetime lubrication. 
 

NEW CONTROL BOARD INSTALLATION 

Set Model Number.  On power up the display 
will show “Reset Model? Continue? 

”

 = Yes 

CLR = No”.  Pres the 

”

 key and display will 

show “No Model Set Save? A = ^ (scroll up) 

”

 = 

Yes CLR = No”.  Press key A to scroll through 
available model numbers DN5800-4, DN3800-4, 
DN5800-E4 (export), DN3800-E4 (export).  With 
vender model displayed that you are installing 
board press the 

”

 key to save. 

 
 
 

Control Board Software 
Update Procedure 

Go in to Set Up Mode 1 of programming. 

UPDATE SOFTWARE

 - Press key “8”

  

(PASSWORD REQUIRED) 
Allows the service technician to manually load 
software if needed.  New software automatically 
loads on power up.  

Caution

:  If this mode is entered 

with no EPROM installed in controller, it will cause 
control board failure.  The following information 
describes how to update software.  All new software 
revisions will automatically update the software 
revision in the control board.  

Important

: EPROM’s 

containing software are sensitive to Electrostatic 
Discharge (ESD).  Failure to handle the EPROM 
carefully could cause damage, which may result in a 
failed control board.  

ALWAYS KEEP THE EPROM 

IN THE ESD TUBE. GROUND YOURSELF ON THE 
VENDER CABINET BEFORE REMOVING THE 
EPROM FROM THE ESD TUBE OR CONTROL 
BOARD.  AN EPROM CAN BE USED TO 
PROGRAM MANY VENDERS, AS LONG AS 
CARE IS TAKEN NOT TO DAMAGE THE 
EPROMS LEGS.

   

ALWAYS TURN POWER OFF 

BEFORE REMOVING OR INSTALLING EPROMS 
IN THE CONTROL BOARD.

  Important Notes:  Use 

the programming section of the manual to program 
the vender. 

1. EPROM 

Removal: 

a.  Power down the Vender.  Ground 

yourself on the vender cabinet 
before removing the EPROM from 
the ESD tube or control board. 

b.  If an EPROM is present in the 

control board, remove the existing 
EPROM. 

i.  Note; An EPROM does not 

need to be in the control 
board after the control 
board has been 
programmed.  The EPROM 
can be used to program 
other boards. 

c.  Verify the pins of the new EPROM 

are not bent before installing in the 
EPROM socket. 

d. Install the new EPROM in the 

EPROM socket.  Ensure the 
EPROM is oriented correctly with its 
reference marker (locator) in the 
same direction as the reference 
marker (locator) of the EPROM 
socket.  Do not rely on the EPROM 
label for orientating the EPROM. 

2. Automatic 

Reprogramming: 

a.  Turn power on to Vender.  When 

auto-updating the display will show 

Summary of Contents for Dixie-Narco DN5800-4

Page 1: ...assfront BevMax 3 5800 4 Vender Model DN5800 4 Production Run 8882AH Higher Manufactured by Dixie Narco Inc P O Drawer 719 Williston SC 29853 0719 803 266 5001 fax 803 266 5049 Visit us on the web www dixienarco com 803 904 630 01 ...

Page 2: ...HARACTERISTICS DN5800 4 HEIGHT 72 1828 8 mm WIDTH 47 1193 8 mm DEPTH CABINET 32 812 8 mm DEPTH WITH SERVICE DOOR 33 5 850 9 mm BASE 3 5 88 9 mm SHIPPING WEIGHT 764 lbs 346kg Glass door is 37 5 876 3 mm wide 68 1727 2 mm high RECEIVING INSPECTION DO NOT STORE THE VENDER OUTSIDE Upon receipt inspect the vender for any shipping damage If there is any damage have the delivery driver note the damage on...

Page 3: ...to the plug or mounted on the cord adjacent to the plug WARNING The GFCI protects against current leakage caused by ground faults The GFCI is not designed to protect against over current or short circuits DO NOT use the TEST and RESET buttons on the GFCI as an ON OFF switch The vending machine supply cord MUST be plugged directly into a properly grounded 3 wire receptacle that is properly protecte...

Page 4: ... electrical outlet so that an extension cord is not required If the machine will be subject to user misuse or vandalism it is recommended that the vender be secured to the floor or wall as described in Dixie Narco Technical Bulletin 344 Due to the large size and weight of the Vender never attempt to move the Vender with a Hand Truck or Stair Climber Use a pallet jack or Vender Cooler Dollies at al...

Page 5: ...e Conlux MDB The vender will support the following domestic MDB Bill validators All available Cashcode MDB All available Coinco MDB All available Mars MDB All available Conlux MDB The vender will support MDB card readers SETTING THE TEMPERATURE CONTROL This vender is equipped with an electronic temperature sensor Defrost is controlled both electronically based on run time of the compressor and wit...

Page 6: ...ECTED FOR TESTING OR REPLACEMENT CLEANING DO NOT USE A WATER JET OR NOZZLE TO CLEAN THE VENDER GLASS DOOR The display glass should be cleaned inside and out with paper towels and glass or non abrasive all purpose cleaner The gasket around the product door should be wiped down using warm water any mild general purpose non abrasive cleaner and a soft towel Never lubricate the gasket and always check...

Page 7: ...oard Software Update Procedure Go in to Set Up Mode 1 of programming UPDATE SOFTWARE Press key 8 PASSWORD REQUIRED Allows the service technician to manually load software if needed New software automatically loads on power up Caution If this mode is entered with no EPROM installed in controller it will cause control board failure The following information describes how to update software All new s...

Page 8: ...d with the new software press the service switch on the control board to enter service menus Advance to UPDATE SOFTWARE Press the Key Display will show Reprogramming Vendor while the yellow LED blinks b Display will show new software revision then return to stand by This confirms new software has been successfully updated Note to remove the EPROM after programming remove power to the vender ground...

Page 9: ...ights Off Time 9 Set Storage Time Set Not Available Time Setup Mode 1 key 3 0 Clear Errors 0 Show Checksum 0 Enter New Password 0 Set Storage Temp Test Vend Test Mode key 9 Factory Diagnostics sub menus A Build software revision build number B Model Set Model Number DN5800 4 DN3800 4 DN5800 E4 DN3800 E4 E Extended Cup All BevMax 3 5800 4 Enabled F Delivery Picker Cup Sensor Option BevMax 3 5800 4 ...

Page 10: ...P14 Cup Signal Y Encoder J5A J5 DEX P15 X Motor Encoder J11A J11 Keypad P2 Product Port J12A J12 Temp Sensor P6A P6 Display J16 Multi Drop Bus P7A P7 Relays U17 EPROM Socket P8 Y Cup Motors P3 Door Switch XY P10A P10 Door Switch B1 Battery J2 Supplier Programming Connector S1 Service Switch J3 Dongle Harness P1 J12A J5A P6A J11A J16 J3 J2 F1 U17 P3 BevMax 3 5800 4 S1 B1 P1A P14 P15 P8 P2 P10A P10 ...

Page 11: ...it Switch Port Motor Port Closed Limit Switch Port LED Port Sensor Port Sensor Electrode Ballast X Motor X Home Switch Y Motor Y Home Switch Temp Sensor Display Keypad AC Box Fan Refrig Lamp Door Switch E lock MDB Motor Power Interrupt Switch E Lock Door Relay Aux E Lock Power Lamp Lamp 120 VAC Relay Control 24 VAC 120 VAC 120 VAC VMC ...

Page 12: ...witch Port Motor Port Closed Limit Switch Port LED Port Sensor Port Sensor Electrode Ballast X Motor X Home Switch Y Motor Y Home Switch Temp Sensor Display Keypad AC Box Fan Refrig Lamp Door Switch E lock MDB X Y Power Interrupt Switch E Lock Door Relay Aux E Lock Power Lamp Lamp 220 VAC Relay Control 24 VDC 24 VAC 220 VAC 220 VAC VMC ...

Page 13: ...Motor Board 80492354xx1 Sensor Plate X Motor 80450184xx1 Y Motor 80450184xx1 Cup Board 80492765xx1 Picker Motor 80450139xx1 Picker Home Sw 80410123xx1 Picker Out Sw 80410126xx1 Cup Home Sw 80410122xx1 Limit Switch 80410122xx1 P5 P3 P4 P1 P1 P2 J3 P6 P3 J1 X Motor Y Motor 80492374xx1 J1 80492826xx1 80492479xx1 ...

Page 14: ...t Diagram Domestic Export Z Control Board 80492772xx1 To Door To DEX Jack To Coin Mech Temp Sensor 80492821xx1 80492825xx1 80492826xx1 80492824xx1 80492836xx1 80492827xx1 80492823xx1 J11 P6 J5 J16 P2 P10 P14 P15 P7 P12 P3 P8 80492819xx1 80492828xx Door Switch Door Switch J3 80492819xx1 P1 ...

Page 15: ...Domestic Export To Cabinet Display 80492386xx1 Keypad 80410121xx1 Electronic lock Vend Sensor Board 80492749xx1 Port Board 80492508xx1 or 80492411xx1 Port Motor To MDB Peripherals IRDA Port Auxiliary Lock Power 80492836xx1 80492867xx1 To Cabinet ...

Page 16: ...former 80492514xx1 To Cabinet To Evaporator Fan BLK BRN WHT BRN To Cabinet Ballast 80492755x Choke 80492042xx1 Light relay Fan relay Comp relay Relays 3 8090026xx1 Light fan compressor 80492754xx1 AC Input Refrigeration 80492755xx1 80492819xx1 80492828xx1 Switch 80491515xx1 AC Distribution Box ...

Page 17: ...Page 16 of 19 BevMax 3 5800 4 Export Power Lighting Diagram TBD ...

Page 18: ... EM US 2255008 3 802 402 13x x1 Overload Compressor FFU130HAX EM 513554617 4 802 402 14x x1 Cover Electrical Component FFU130HAX EM 13555028 5 802 402 16x x1 Relay Compressor Start FFU130HAX EM 213516051 6 802 402 18x x1 Capacitor Compressor Start FFU130HAX EM US 3252378 7 802 402 20x x1 Cap Capacitor FFU130HAX EM 2254002 8 802 402 15x x1 Cord Relief FFU130HAX EM 513545045 9 802 402 21x x1 Holder ...

Page 19: ... assy 4 NA OPEN 5 ground 115 VAC Hot switched for fan motor 6 ground 115 VAC Hot switched for lights 7 ground 0 VAC Neutral 8 ground 0 VAC Neutral 9 ground 10 VAC Neutral Domestic Test Measurements 4 Pin P7 AC Distribution Box 1st lead to Pin 2nd lead to Domestic Reading When 4 pin connector is unplugged OHMS reading 1 2 Lights control relay coil 570 ohms 3 2 Fan control relay coil 570 ohms 4 2 Co...

Page 20: ...g bolt 800 305 29x x1 bracket 647 071 08x x3 Shipping location bottom left corner of cabinet Store the shipping bolt and bracket for future use as illustrated The Shipping Bolt must ne installed any time the machine is moved or transported Failure to do so may result in damage to the XY system Storage location bottom left corner of cabinet ...