48
ADDITIONAL INFORMATION & FEATURES Section 4
REMO
REMO
REMO
REMO
REMOTE PR
TE PR
TE PR
TE PR
TE PRO
O
O
O
OT
T
T
T
TOCOL
OCOL
OCOL
OCOL
OCOL
The Jobs are preloaded on to the wrench.
The Jobs are selected by an ID sent by Remote Protocol.
When the wrench is activated, readings can be taken.
These readings are sent back one at a time and each one is acknowledged before
allowing the next reading.
Please contact Crane Electronics for the Protocol.
ST
ST
ST
ST
STA
A
A
A
ATUS BAR
TUS BAR
TUS BAR
TUS BAR
TUS BAR
Set in Measurement mode setup of Quick Store or Jobs.
Only shown if Peak or Peak + Angle measurement.
‘Target only’ setup has right hand vertical line set as primary parameter target value
and left hand vertical line is set as zero.
With ‘Limits’ setup has LSL, Target and USL limit lines evenly spaced on right and not
in proportion to their values. This means any value between two limits takes into
account the difference between those limit lines and so the rate the status bar travels
across the display can appear to speed up or slow down as it passes limit lines.
The left hand most limit line is given the value LSL – (USL – LSL) or zero if the
answer is negative. The status bar will not be displayed until it reaches this left hand
limit line.
If control limits are enabled, they are placed between the other limits in proportion to
their value.
The status bar will start when measurement cycle starts. This means it may suddenly
appear if measuring torque as the torque threshold is between the limit lines. If angle
LSL is set as zero (is permitted), then at beginning of cycle status bar will appear
already at LSL.
One of the screen formats (Press