Device data
Supply voltage
10 V to 16 V DC, optionally up to 42 V DC (High-voltage
option)
Current consumption
Standby mode:
approx. 30 mA
Measuring mode: approx. 100 mA
Coin acceptance: approx. 100 mA + approx. 3 W
Battery model
Sleep mode:
≤
15 µA
Standby mode:
approx. 30 mA (wake-up mode)
Measuring mode: approx. 100 mA
Coin acceptance: approx. 100 mA + approx. 3 W
Electric strength
Max. 35 V
Inputs/outputs
Current-carrying
Max. 150 mA (open collector)
capacity, outputs
Temperature range
-25 °C to 70 °C
Temperature change
Max. 0.2 °C/min.
Rel. humidity
Up to 93 %
Condensation
Not permitted
Machine interfaces
Standard/Casino
6 coin signal parallel outputs (open collector)/6 individual
inhibit inputs (active low)
Common inhibit input (active high)
Return output (active low)
BDTA 14
4 coin signal parallel outputs (open collector) (active low)
Common inhibit input (active high)
Return output (active low)
Wake-up input/output (active low)
String output (acitve low)