T
ECHNICAL
DATA
G-13.mft standard/Casino/SGI/BDTA/AMU
54
National Rejectors, Inc. GmbH, Buxtehude
G-13.mft with G-40 BDTA interface – machine
Pin assignment
Pin 1
IN
Single inhibit line 4: active high
Pin 2
IN
Single inhibit line 5: active high
Pin 3
IN
Single inhibit line 2: active high
Pin 4
IN
Single inhibit line 6: active high
Pin 5
OUT
Return line: active low
Pin 6
IN
Common inhibit line: active low
Pin 7
OUT
Coin line 4: active low
Pin 8
–
Ground (GND)
Pin 9
OUT
Coin line 6: active low
Pin 10
OUT
Coin line 2: active low
Pin 11
OUT
Coin line 5: active low
Pin 12
OUT
Coin line 3: active low
Pin 13
OUT
Coin line 1: active low
Pin 14
IN
Single inhibit line 3: active high
Pin 15
IN
Single inhibit line 1: active high
Pin 16
–
Operating voltage U
O
= +12 V (10 V–27 V DC)
All signals must be debounced from the input side.
Interface description
Coin lines
Coin validator signals coin accepted in the corresponding coin channel
(usually with one impulse, if there are insufficient lines with multiple
impulses)
Return line
After the return button has been pressed, the coin validator signals the
opening of the measurement and validation area
Common inhibit line
Machine inhibits coin acceptance
Single inhibit lines
Machine inhibits coin assigned to the signal line