F
UNCTION
G-13.mft standard/Casino/SGI/BDTA/AMU
22
National Rejectors, Inc. GmbH, Buxtehude
○○
pre-signal
(10 ms)
1
0
○○○
○○○
○
○
no coin signal
1
0
no release signal
release signal
(min. 1 ms)
1
0
pre-signal
(10 ms)
coin signal*
(5–500 ms, typical: 50 ms)
1
0
○○
○
○○
○
○○
○○
During the 10-ms pre-signal the machine control system must transmit a
1-ms release signal to the validator via the inhibit signal line (deactivate line),
so that the coin can be accepted.
Coin released by machine
Coin signal line
Inhibit signal line
Time (t)
*
only if coin passed accepted coin sensors
Coin rejected by machine
Coin signal line
Inhibit signal line
Time (t)
Coin impulse length
The length of the coin impulses that are sent from the coin validator to the
machine can be set individually to suit the machine.
Possible setting: 5 to 500 ms, default setting: 100 ms (50 ms for AMU
model).
You can also assign a different impulse length to each coin type, but
in this case only one impulse will always be transmitted and not a
specific higher impulse number for the purpose of differentiating the
coins (see section "Transfer of coin values by means of coin impulses
and via coin signal lines" in this chapter).