G-13.mft standard/Casino/SGI/BDTA/AMU
F
UNCTION
27
National Rejectors, Inc. GmbH, Buxtehude
High-voltage applications up to 42 V
If the coin validator is to be supplied with more than 10–16 V, at the factory
it can be equipped with a switching power supply which makes a supply
voltage of up to 42 V possible (not available for retrofitting).
Inverted common inhibit signal line (only standard and Casino model)
By default, the machine inhibits coin acceptance by transmitting an active-
high signal via the common inhibit signal line (pin 6, standby position of the
line is "Low").
The G-13.mft standard and Casino can be ordered with an inverted common
inhibit signal line (common inhibit, when active-low, standby position of the
line is "High") (see section "Interfaces (pin assignment and connection
diagrams)" in Chap. 9 "Technical data").
Summary of Contents for NRI G-13.mft Standard
Page 2: ......