Troubleshooting
Malfunctions can occur in all electronic devices. These do not always have
to be faults in the device. In many cases the reason is improper connections
or incorrect settings. Therefore: please first of all check, whether the
malfunction can simply be remedied using the following table:
Possible causes
No power supply
Return lever/button
pressed/got stuck
Coin runway dirty
Coin inhibited
Remedy, hints
• Connect ribbon cable to coin validator and
machine correctly
• Supply machine with voltage
Make sure, that return lever/button is not
inadvertently pressed
Open flight deck and clean coin runway
(see section "Cleaning coin validator" in this
chapter)
• Make sure that (common) inhibit signal
line (pin 6) is not activated by machine
(see section "Interfaces (pin assignment
and connection diagrams)" in Chap. 9
"Technical data")
• Make sure that the single inhibit signal line
assigned to the coin is not activated by
the machine or the correct single inhibit
line is assigned (if necessary, correct
with WinEMP) (see section "Interfaces
(pin assignment and connection
diagrams)" in Chap. 9 "Technical data")
• Make sure that the coin is not inhibited
using the DIL switches on the rear of the
device or not only the narrow coin
channel is enabled and the normal one is
inhibited (see section "Inhibiting coins/
activating narrow coin channel" in Chap. 6
"Operation")
Problem
Coin
validator
does not
accept coin