CROSSOVER M
| PRODUCTSHEET | 2021 | EN
|
4
Anchoring and ballast
4 options
OPTION 3 |
Ballast TÜV
Ballast TÜV Straight with concrete tiles
Ballast TÜV Straight
(set of 6)
Ballast TÜV Multiple
4x
60 kg
(per piece)
60 kg
(per piece)
You can place 50x50x4 cm concrete tiles
on both ballast frames and secure them with
straps.
Ballast TÜV Straight is a ballast
anchoring for a singel Crossover
or Hexadome feet.
Topview connected Crossovers with
Crossovers (Village).
Ballast TÜV Straight is used as ballast
anchoring for one Crossover foot.
Ballast TÜV Multiple is used as ballast
anchoring for connecting multiple feet.
Ballast TÜV Straight
Ballast TÜV Multiple
EXAMPLE |
Ballast TÜV
S
Ballast TÜV Straight can be used if the
surface is not suitable for anchoring. The
Ballast TÜV Straight contains 1 interface
(1)
(Crossover M-L and Hexadome M) and
2 ballast frames
(2)
(suitable for
Crossover M-L and Hexadome M-L)
The numbers and weight per foot below are
based on:
• Peak wind velocity
• Measured on the highest point of the structure
• All side panels closed
• Ballast system used
Km/h
m/s
Knots
78,8 km/h
21,9 kg
42,5 knots
Max. peak velocity according to European standards:
Required ballast according to European standards:
Ballast
Per peak wind velocity
Ballast
Requirements per peak wind velocity
S
M
S
S
S
S
S
S
M
M
M
M
M
M
M
M
Ballast TÜV Multiple can be used if the
surface is not suitable for anchoring. The
Ballast TÜV Multiple contains 1 interface
(1)
and 4 ballast frames
(2)
.
Ballast TÜV Multiple is a ballast
anchoring for multiple feet (Village).
Wind peak
Balast
(per foot)
40 km/h
73 kg
50 km/h
115 kg
60 km/h
165 kg
70 km/h
255 kg
80 km/h
294 kg
90 km/h
- kg
100 km/h
- kg
Ballast
(per foot)
285 kg
1
2
190 cm
95 cm
6 cm
98 cm
50 cm
1
2
6 cm
98 cm
94 cm