5925 Heisley Road • Mentor, OH 44060-1833
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
LITTLE CAESARS HOT-N-READY
OPERATING and MAINTENANCE INSTRUCTIONS
Model: H138NPS-CLC Pass-Thru Hot Cabinet Series
Pass-Thru
Holding Cabinet
FL-2254LC
Rev. 7 (7/07)
Page 4 of 4
G
W
TERMINAL BLOCK
POWER
SWITCH
5-20P
120V; 20A
FAN
BM
A
6-15P PLUG
240V, 15A
1
2
2
1
3
3
4
4
5
6
HIGH LIMIT
10
9
8
5
4
t°
6
7
15
16
15
16
4
5
20
HEATER AIR
FAN
BM
HIGH LIMIT
21
7
8
23
24
G
TEMPERATURE CONTROL BOARD
SENSOR
G
208/240V. UNITS - ATTACH WIRE #15 TO
TERMINAL #10 OF TEMP. CONT. BOARD.
TERMINAL #9 OF TEMP. CONT. BOARD.
120V. UNITS - ATTACH WIRE #15 TO
WIRE NUT UNUSED LEAD.
NOTES:
= PROTECTIVE SLEEVE
BM = BLOWER MOTOR
FAN = VENT FAN
A = AMBER (YELLOW) LIGHT
HOT UNIT REPLACEMENT PARTS:
CABINET REPLACEMENT PARTS:
DESCRIPTION
120 VOLT
240 VOLT
DESCRIPTION
CMP NO.
Power Unit
0675-048LC
0675-057LC
Door, Full
1221-540
Heater, Air
Door, Full, Window
1221-550
High Limit
Door, Half, Window
1221-535-01
Thermometer
5238-030
5238-030
Door, Half
1221-534
Thermostat, Air
Door Gasket, Full
0861-246
Power Cord
-K
Door Gasket, Half
0861-245
Power Switch
0808-116
0808-116
Door Hinge (Full Door)
0519-089
Power Light
Door Hinge (Half Door)
Vent Fan
Door Latch
1006-120-01
Caster
0569-306
Caster with Brake
0569-306-B
Angle Slide Set
Post, Angle Slide
Blower Guard
WIRING DIAGRAM
Full-Height Pass-Thru Units