Analog Input Signal Descriptions
INPUT DESCRIPTION
RGB_IN_For_Out1
Input signal to route to RGB Output 1.
RGB_IN_For_Out2
Input signal to route to RGB Output 2.
RGB_IN_For_SC
Input signal to route to Scan Converter.
VIDEO_IN_For_Out1 Input signal to route to VIDEO Output 1.
VIDEO_IN_For_Out2 Input signal to route to VIDEO Output 2.
SC-Brightness*
Brightness control for Scan Converter output
signal.
SC-Contrast*
Contrast control for Scan Converter output
signal.
SC-Saturation*
Saturation control for Scan Converter output
signal.
SC-Sharpness*
Sharpness control for Scan Converter output
signal.
SC-H_Position*
Scan Converter horizontal position.
SC-H_SIZE*
Scan Converter horizontal size.
SC-V_POSITION*
Scan Converter vertical position.
SC-V_SIZE*
Scan Converter vertical size.
* Analog input signal values range from 0 to 100%.
Signal Values for “RGB_IN_FOR_OUTx” & “VID_IN_FOR_OUTx”
SIGNAL
VALUE
SOURCE
0
No input source selected. No output.
1
Source 1 (RGB_IN_FOR_OUTx & VID_IN_FOR_OUTx).
2
Source 2 (RGB_IN_FOR_OUTx & VID_IN_FOR_OUTx).
3
Source 3 (RGB_IN_FOR_OUTx & VID_IN_FOR_OUTx).
Source 4 (RGB_IN_FOR_OUTx)
OR
4
Scan Converter (VID_IN_FOR_OUTx).
Example Program
An example program for the C2N-MMS-SC is available from the
Crestron FTP site (ftp://ftp.crestron.com/Examples/). Search for the file
C2N-MMS-SC.ZIP that contains the example program, associated files
and a README.TXT file that describes the program.
Operations & Installation Guide - DOC. 6138
Scan Converter Card for C2N-MMS: C2N-MMS-SC
•