CAEN-BLOCK

 – Network Block 

Introduction 

NOTE:  

Unless otherwise indicated, the lighting 

system specified in this guide is modular, requiring 
assembly in the field by a licensed electrician, in 
accordance with all national and local codes. 

Crestron

 Network Block (CAEN-BLOCK) is a 

termination block that provides four termination ports for 
Cresnet

 wiring. The unit can be installed into a Crestron 

Automation Enclosure (CAEN-Series) to continue the 
connectivity of Cresnet from an enclosure that contains a 
Crestron Professional Automation Computer (PAC2) or 
any 2-Series processor.  

If you require a UL Listed panel, Crestron offers this 
service through its UL Listed panel shop. This 
includes complete in factory system configuration 
and assembly by Crestron for an additional fee.  

The unit also has two 5-pin connections that provide 
communication to the modules. Contact closure override 
signals that produce an emergency over ride of the 
modules are also sent through these connections.  

Wiring 

The CAEN-BLOCK distributes 24 volts direct current 
(VDC), Cresnet Y and Z data signals, and ground. Using 
any one of the NET connectors as an input source 
(receiving power, data, and ground from a PAC2), the 
remaining connectors may be used as outputs to other 
equipment (i.e., CAEN-BLOCKs in other enclosures or 
other Cresnet devices) to continue the connectivity of 
Cresnet from an enclosure that contains a 2-Series 
processor to other Cresnet devices. 

The unit is a pass-through device with a Cresnet power 
factor of zero. 

Network Block Dimensions & Weight 

Height

Width

Depth

Dimensions

2

6

3

/

4

Weight

3.4

Dimensions are provided in inches. 
Weight is provided in ounces.

 

Attach the module interconnect cable (supplied) to 
connect the CAEN-BLOCK to the Crestron lighting 
modules (CLX-Series) installed in the enclosure.  

Installation 

NOTE:  

When making the connection to a module in 

single-wide enclosure

, be sure to use the 5-pin 

module interconnect connector marked 

LEFT 

as 

shown in the illustration below.  

The CAEN-BLOCK must be mounted in accordance with 
all national and local codes. Use the two screws (8Bx1/4”, 
supplied) to attach a CAEN-BLOCK to an enclosure. 
Refer to the two drawings below for location and 
orientation within an enclosure.  

When a switch contact closure is received between the 
“G” connections and the “L” or “R” connection (R is used 
in a double-wide enclosure only) on the CAEN BLOCK, 
the respective left or right column of modules will set the 
lights to the programmed emergency over-ride state. 

Example of CAEN-BLOCK Location and Orientation within a 
Single-Wide Enclosure 

OVER RIDE

G L R

CAEN-BLOCK

NET

Z

Y

24

G

CRESTRON

Z

Y

24

G

LEFT

Z

Y

24

G

SINGLE WIDTH CABINET
DOUBLE WIDTH CABINET

Z

Y

24

G

G L R

RIGHT

MODULE

CAEN-BLOCK

 

CAEN-BLOCK Wiring Connections 

OVER RIDE

G L R

CAEN-BLOCK

NET

Z

Y

24

G

CRESTRON

Z

Y

24

G

LEFT

Z

Y

24

G

SINGLE WIDTH CABINET

DOUBLE WIDTH CABINET

Z

Y

24

G

G L R

RIGHT

TO MODULES

TO OVERRIDE

  SWITCH

  TO

CRESNET

LEFT

RIGHT

24     Y      Z     G  OVER

                             RIDE

G     Z     Y     24

OVER

RIDE

 

Example of CAEN-BLOCK Location and Orientation within a 
Double-Wide Enclosure 

OVER RIDE

G L R

CAEN-BLOCK

NET

Z

Y

24

G

CRESTRON

Z

Y

24

G

LEFT

Z

Y

24

G

SINGLE WIDTH CABINET
DOUBLE WIDTH CABINET

Z

Y

24

G

G L R

RIGHT

MODULE

CAEN-BLOCK

 

Crestron Electronics, Inc.

 

Installation Guide – DOC. 5994A

 

15 Volvo Drive   Rockleigh, NJ 07647

 

(2002076)

 

Tel: 888.CRESTRON

 

11.05

 

Fax: 201.767.7576

  

Specifications subject to 

 

www.crestron.com

 

change without notice.

 