Crestron
CEN-UPS1250
Uninterruptible Power Supply
Installation
The CEN-UPS1250 may be installed on a flat, solid surface or rack mounted. Proper
placement of the CEN-UPS1250 should be accomplished in accordance with the
following procedures.
WARNING:
The CEN-UPS1250 weighs 62 pounds (28.2 kg) and we recommend
that two people lift the unit. If the battery is removed, as described on the following
page, lifting and positioning the unit is much easier. Lift the unit carefully by firmly
grasping both sides of the unit in the middle. Failure to comply may result in
personal injury and/or damage to the equipment.
WARNING:
The CEN-UPS1250 should not be lifted or moved using the two
handles on the front panel. These are intended only for removing the front panel to
access the internal battery, not for lifting or positioning the unit.
Ventilation
The CEN-UPS1250 should be used in a well-ventilated area. The venting holes
should not be obstructed under any circumstances.
To prevent overheating, do not operate this product in an area that exceeds the
environmental temperature range listed in the table of specifications. Consider using
forced air ventilation and/or incrementing the spacing between units to reduce
overheating. Consideration must be given if installed in a closed or multi-unit rack
assembly since the operating ambient temperature of the rack environment may be
greater than the room ambient temperature. Contact with thermal insulating materials
should be avoided on all sides of the unit.
Removing the Battery Pack
To remove the battery pack:
1. Remove the battery retaining bar after loosening the thumb screw that holds
it in place. (Refer to illustration on page 15.)
2. Disconnect the battery wire connector.
3. Pull the battery straight back.
4. Press in the retaining tabs to allow the battery to come out completely.
Installing on a Flat Surface
Place the unit on a flat, solid surface that is capable of supporting at least 62 pounds
(28.2 kg).
NOTE:
Avoid placing other components directly on top of or behind the unit. Leave
at least one inch of space on all sides to allow for proper air ventilation. Do not block
the fan.
Operations & Installation Guide – DOC. 6635E
Uninterruptible Power Supply: CEN-UPS1250
•
11